8 Part Load performanceMMY-AP3424* (34HP, 96kW system)Cooling Compressor + Oudoor Fan Power consumption (kW)Outdoor UnitDry-Bulb(°C)Outdoor Unit100%CoolingCapacity(kW)100%Capacity90%Capacity80%Capacity70%Capacity60%Capacity50%Capacity40%Capacity30%Capacity40 °C 89.3 25.9 21.3 17.3 13.8 10.9 8.61 6.87 5.7135 °C 96.0 24.0 19.7 16.0 12.8 10.1 7.97 6.36 5.2930 °C 96.0 19.8 16.4 13.3 10.7 8.58 6.86 5.58 4.7325 °C 96.0 16.7 13.8 11.3 9.14 7.36 5.95 4.91 4.2220 °C 96.0 15.1 12.5 10.3 8.37 6.78 5.53 4.60 4.0015 °C 96.0 14.5 12.1 9.92 8.10 6.60 5.41 4.54 3.98Indoor air temperature conditions : 27.0 °C dry-bulb / 19.0 °C wet bulbHeating Compressor + Oudoor Fan Power consumption (kW)Outdoor UnitOutdoorUnit 100%100% 90% 80% 70% 60% 50%Dry-Bulb Wet-Bulb HeatingCapacity Capacity Capacity Capacity Capacity Capacity( °C) ( °C) Capacity(kW)40%Capacity30%Capacity15 13.7 108.0 20.6 17.1 14.2 11.8 9.86 8.19 6.72 5.3411 9.8 108.0 22.3 18.3 15.1 12.4 10.2 8.42 6.86 5.437 6 108.0 24.7 20.0 16.2 13.2 10.7 8.71 7.04 5.540 -0.7 94.7 23.4 18.9 15.3 12.5 10.1 8.25 6.66 5.24-5 -5.6 84.5 22.4 18.2 14.7 11.9 9.71 7.90 6.39 5.03-10 -10.5 73.8 21.4 17.4 14.1 11.4 9.29 7.56 6.11 4.81-14.5 -15 63.5 20.5 16.6 13.5 10.9 8.91 7.25 5.86 4.61Indoor air temperature conditions : 20.0 °C dry-bulbMMY-AP4024* (40HP, 112kW system)Cooling Compressor + Oudoor Fan Power consumption (kW)Outdoor UnitDry-Bulb(°C)Outdoor Unit100%CoolingCapacity(kW)100%Capacity90%Capacity80%Capacity70%Capacity60%Capacity50%Capacity40%Capacity30%Capacity40 °C 104.2 32.0 26.3 21.3 17.1 13.5 10.6 8.49 7.0635 °C 112.0 29.6 24.4 19.7 15.8 12.5 9.84 7.86 6.5330 °C 112.0 24.5 20.2 16.5 13.3 10.6 8.48 6.89 5.8525 °C 112.0 20.6 17.0 13.9 11.3 9.10 7.35 6.06 5.2220 °C 112.0 18.6 15.5 12.7 10.3 8.38 6.83 5.68 4.9515 °C 112.0 17.9 14.9 12.3 10.0 8.15 6.68 5.60 4.91Indoor air temperature conditions : 27.0 °C dry-bulb / 19.0 °C wet bulbHeating Compressor + Oudoor Fan Power consumption (kW)Outdoor UnitOutdoorUnit 100%100% 90% 80% 70% 60% 50%Dry-Bulb Wet-Bulb HeatingCapacity Capacity Capacity Capacity Capacity Capacity( °C) ( °C) Capacity(kW)40%Capacity30%Capacity15 13.7 127.0 25.3 21.0 17.5 14.6 12.1 10.1 8.28 6.5811 9.8 127.0 27.5 22.6 18.5 15.3 12.6 10.4 8.45 6.697 6 127.0 30.4 24.6 20.0 16.2 13.2 10.7 8.67 6.820 -0.7 111.4 28.8 23.3 18.9 15.3 12.5 10.2 8.20 6.46-5 -5.6 99.4 27.6 22.4 18.1 14.7 12.0 9.74 7.87 6.19-10 -10.5 86.7 26.4 21.4 17.3 14.1 11.4 9.31 7.53 5.92-14.5 -15 74.6 25.3 20.5 16.6 13.5 11.0 8.93 7.21 5.68Indoor air temperature conditions : 20.0 °C dry-bulb8 -10A

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!