<strong>Ondatherm</strong> <strong>900</strong> - <strong>roofing</strong>120A - Metal CladdingAccessoriesMatching flashings and support zeds.Fittings and accessories generally221 Accessories Cappings, closure pieces, flashings, trims cills, gutters, fillers, spacers, tapes, sealants, fixings etc, where notspecified, are to be types as recommended by ArcelorMittal - Arval.223 Isolating Tape A type recommended for the purpose by ArcelorMittal - Arval. Apply to those surfaces of supports whichwould otherwise be in contact with cladding or accessories after fixing.310A Purpose madecold formedmetalaccessoriesMaterial:Thickness/gauge:Finish/colour:Galvanized cold rolled steel sheet grade S220 GD.0.75mm minimum.External - Colorissime range.Internal - Interior 912Workmanship as NBS Standard Section Z22.RFix to <strong>Ondatherm</strong> /Structure with 4.8mm stitcher screws (or rivets) at <strong>900</strong>mm nominalcenters.Gutter support bracketmay be formed byextending snap-on coverplate (depending Gutter onsupport loading) bracket<strong>Ondatherm</strong> <strong>900</strong> roof panelStitcher fixings at <strong>900</strong>mm centres75Main panel fixing (to job specific calculations)Air seal - 8mm diameter butyl rubber sealant BY OTHERSAir seal - 6mm diameter bead of gun grade sealant BY OTHERSTrimline gutter BY OTHERSEaves galv support angle BY OTHERSSteelwork BY OTHERSDownpipe BY OTHERSNote: These details are for guidance only.The individual building designer mustsatisfy him/herself of any and all coldbridging issues and adjust the finaldesign layout accordingly.<strong>Ondatherm</strong> <strong>900</strong> wall panelN° H005 - Eaves Gutter 1 (Note: All installations should comply with the recommendations contained in MCRMA Techinical Papers N° 12 & 14; BS3200 and other relevant national standards)


<strong>Ondatherm</strong> <strong>900</strong> - <strong>roofing</strong>120A - Metal CladdingAccessoriesMatching flashings and support zeds.Fittings and accessories generally221 Accessories Cappings, closure pieces, flashings, trims cills, gutters, fillers, spacers, tapes, sealants, fixings etc, where notspecified, are to be types as recommended by ArcelorMittal - Arval.223 Isolating Tape A type recommended for the purpose by ArcelorMittal - Arval. Apply to those surfaces of supports whichwould otherwise be in contact with cladding or accessories after fixing.310A Purpose madecold formedmetalaccessoriesMaterial:Thickness/gauge:Finish/colour:Galvanized cold rolled steel sheet grade S220 GD.0.75mm minimum.External - Colorissime range.Internal - Interior 912Workmanship as NBS Standard Section Z22.RFix to <strong>Ondatherm</strong> /Structure with 4.8mm stitcher screws (or rivets) at <strong>900</strong>mm nominalcenters.Parapet galv support zed BY OTHERSParapet capping BY OTHERSAir seal - 8mm diameter butyl rubber sealant BY OTHERS75<strong>Ondatherm</strong> <strong>900</strong> roof panelMain panel fixing (rigime to job specific calculations)Steelwork BY OTHERSSteelwork BY OTHERSInsulated membrane lined composite gutter BY OTHERSWall panelDownpipe BY OTHERSNote: These details are for guidance only.The individual building designer mustsatisfy him/herself of any and all coldbridging issues and adjust the finaldesign layout accordingly.N° H006 - Eaves Gutter 2 (Note: All installations should comply with the recommendations contained in MCRMA Techinical Papers N° 12 & 14; BS3200 and other relevant national standards)


<strong>Ondatherm</strong> <strong>900</strong> - <strong>roofing</strong>120A - Metal CladdingAccessoriesMatching flashings and support zeds.Fittings and accessories generally221 Accessories Cappings, closure pieces, flashings, trims cills, gutters, fillers, spacers, tapes, sealants, fixings etc, where notspecified, are to be types as recommended by ArcelorMittal - Arval.223 Isolating Tape A type recommended for the purpose by ArcelorMittal - Arval. Apply to those surfaces of supports whichwould otherwise be in contact with cladding or accessories after fixing.310A Purpose madecold formedmetalaccessoriesMaterial:Thickness/gauge:Finish/colour:Galvanized cold rolled steel sheet grade S220 GD.0.75mm minimum.External - Colorissime range.Internal - Interior 912Workmanship as NBS Standard Section Z22.RFix to <strong>Ondatherm</strong> /Structure with 4.8mm stitcher screws (or rivets) at <strong>900</strong>mm nominalcenters.Air seal - 8mm diameter butyl rubber sealant BY OTHERS<strong>Ondatherm</strong> <strong>900</strong> Roof PanelStitcher fixings at <strong>900</strong>mm centresMain panel fixing (Regime tojob specific calculations)75Eaves galv support angle BY OTHERSMain panel fixing (Regime tojob specific calculations)Air Seal - 6mm diameter bead ofgun grade sealant BY OTHERSSteelwork BY OTHERSEaves flashing BY OTHERSSteelwork BY OTHERSEaves flashing BY OTHERS<strong>Ondatherm</strong> <strong>900</strong> wall panelNote: These details are for guidance only.The individual building designer mustsatisfy him/herself of any and all coldbridging issues and adjust the finaldesign layout accordingly.N° H007 - Eaves Overhangs (Note: All installations should comply with the recommendations contained in MCRMA Techinical Papers N° 12 & 14; BS3200 and other relevant national standards)


<strong>Ondatherm</strong> <strong>900</strong> - <strong>roofing</strong>120A - Metal CladdingAccessoriesMatching flashings and support zeds.Fittings and accessories generally221 Accessories Cappings, closure pieces, flashings, trims cills, gutters, fillers, spacers, tapes, sealants, fixings etc, where notspecified, are to be types as recommended by ArcelorMittal - Arval.223 Isolating Tape A type recommended for the purpose by ArcelorMittal - Arval. Apply to those surfaces of supports whichwould otherwise be in contact with cladding or accessories after fixing.310A Purpose madecold formedmetalaccessoriesMaterial:Thickness/gauge:Finish/colour:Galvanized cold rolled steel sheet grade S220 GD.0.75mm minimum.External - Colorissime range.Internal - Interior 912Workmanship as NBS Standard Section Z22.RFix to <strong>Ondatherm</strong> /Structure with 4.8mm stitcher screws (or rivets) at <strong>900</strong>mm nominalcenters.<strong>Ondatherm</strong> internal parapet <strong>900</strong> wall panel<strong>Ondatherm</strong> <strong>900</strong> wall panelDirection Direction Of ofLaylayVerge zed support BY OTHERS forsite cut panel applicationsAir Seal - 6mm diameter butylrubber sealant BY OTHERSSteelwork BY OTHERSCill closure flashing BY OTHERS9 x 3mm butylrubber sealant<strong>Ondatherm</strong> <strong>900</strong> roof panelPIR board insulation with Alfasbond FR aerosolapplied insulation to fill any gaps if requiredto maintain continunity of insulationGalv support angle BY OTHERSNote: These details are for guidance only.The individual building designer mustsatisfy him/herself of any and all coldbridging issues and adjust the finaldesign layout accordingly.Air seal - 8mm diameter butyl rubber sealant BY OTHERSMain panel fixing (Regime to job specific calculations)<strong>900</strong> to next panel moduleSteelwork BY OTHERSN° H008 - Verge - parapet (Note: All installations should comply with the recommendations contained in MCRMA Techinical Papers N° 12 & 14; BS3200 and other relevant national standards)


<strong>Ondatherm</strong> <strong>900</strong> - <strong>roofing</strong>120A - Metal CladdingAccessoriesMatching flashings and support zeds.Fittings and accessories generally221 Accessories Cappings, closure pieces, flashings, trims cills, gutters, fillers, spacers, tapes, sealants, fixings etc, where notspecified, are to be types as recommended by ArcelorMittal - Arval.223 Isolating Tape A type recommended for the purpose by ArcelorMittal - Arval. Apply to those surfaces of supports whichwould otherwise be in contact with cladding or accessories after fixing.310A Purpose madecold formedmetalaccessoriesMaterial:Thickness/gauge:Finish/colour:Galvanized cold rolled steel sheet grade S220 GD.0.75mm minimum.External - Colorissime range.Internal - Interior 912Workmanship as NBS Standard Section Z22.RFix to <strong>Ondatherm</strong> /Structure with 4.8mm stitcher screws (or rivets) at <strong>900</strong>mm nominalcenters.Parapet capping flashing BY OTHERS9 x 3mm butylrubber sealantVerge zed support BY OTHERS forsite cut panel applications<strong>Ondatherm</strong> <strong>900</strong> roof panelAir seal - 8mm diameter butyl rubber sealant BY OTHERSProfiled Filler Sealed Top AndBottom With Gun Grade SealantCleader angle BY OTHERSMain panel fixing (Regime to job specific calculations)<strong>900</strong> to next panel moduleAir seal - 6mm diameter butyl rubber sealant BY OTHERSDirection of Direction lay Of LaySteelwork BY OTHERS<strong>Ondatherm</strong> <strong>900</strong> Wall PanelNote: These details are for guidance only.The individual building designer mustsatisfy him/herself of any and all coldbridging issues and adjust the finaldesign layout accordingly.N° H009 - Verge (Note: All installations should comply with the recommendations contained in MCRMA Techinical Papers N° 12 & 14; BS3200 and other relevant national standards)


<strong>Ondatherm</strong> <strong>900</strong> - <strong>roofing</strong>120A - Metal CladdingAccessoriesMatching flashings and support zeds.Fittings and accessories generally221 Accessories Cappings, closure pieces, flashings, trims cills, gutters, fillers, spacers, tapes, sealants, fixings etc, where notspecified, are to be types as recommended by ArcelorMittal - Arval.223 Isolating Tape A type recommended for the purpose by ArcelorMittal - Arval. Apply to those surfaces of supports whichwould otherwise be in contact with cladding or accessories after fixing.310A Purpose madecold formedmetalaccessoriesMaterial:Thickness/gauge:Finish/colour:Galvanized cold rolled steel sheet grade S220 GD.0.75mm minimum.External - Colorissime range.Internal - Interior 912Workmanship as NBS Standard Section Z22.RFix to <strong>Ondatherm</strong> /Structure with 4.8mm stitcher screws (or rivets) at <strong>900</strong>mm nominalcenters.Mineral fibre insulation - site appliedRidge flashing BY OTHERS with a 150mmsealed overlap or butt strapsInternal rRidge flashing with 150mm overlap sealed withair Sseal Vapourflex or gun grade sealant BY OTHERSProfile filler set back 80mm to100mm to prevent bird ingress<strong>Ondatherm</strong> <strong>900</strong> roof panel<strong>Ondatherm</strong> <strong>900</strong> roof panelends turned up on siteAir seal - 8mm diameter butylrubber sealant BY OTHERSMain panel fixing (Regime tojob specific calculations)Profiled filler sealed top and bottomwith gun grade sealantSteelwork BY OTHERSRidge flashing BY OTHERSIsometric view of ridge componentsSnap on cover plateNote: These details are for guidance only.The individual building designer mustsatisfy him/herself of any and all coldbridging issues and adjust the finaldesign layout accordingly.<strong>Ondatherm</strong> <strong>900</strong> roof panel<strong>Ondatherm</strong> <strong>900</strong> roof panelends turned up on siteN° H010 - Ridge (Note: All installations should comply with the recommendations contained in MCRMA Techinical Papers N° 12 & 14; BS3200 and other relevant national standards)


<strong>Ondatherm</strong> <strong>900</strong> - <strong>roofing</strong>120A - Metal CladdingAccessoriesMatching flashings and support zeds.Fittings and accessories generally221 Accessories Cappings, closure pieces, flashings, trims cills, gutters, fillers, spacers, tapes, sealants, fixings etc, where notspecified, are to be types as recommended by ArcelorMittal - Arval.223 Isolating Tape A type recommended for the purpose by ArcelorMittal - Arval. Apply to those surfaces of supports whichwould otherwise be in contact with cladding or accessories after fixing.310A Purpose madecold formedmetalaccessoriesMaterial:Thickness/gauge:Finish/colour:Galvanized cold rolled steel sheet grade S220 GD.0.75mm minimum.External - Colorissime range.Internal - Interior 912Workmanship as NBS Standard Section Z22.RFix to <strong>Ondatherm</strong> /Structure with 4.8mm stitcher screws (or rivets) at <strong>900</strong>mm nominalcenters or as recommended by rooflight manufacturer.Danpalon Danpalon Polycarbonate polycarbonate Sheet sheet (10mm(or Minimum) similar)10mm minimum by othersR1300Note: These details are for guidance only.The individual building designer mustsatisfy him/herself of any and all coldbridging issues and adjust the finaldesign layout accordingly.<strong>Ondatherm</strong> <strong>900</strong> Roof Panel<strong>900</strong><strong>Ondatherm</strong> <strong>900</strong> Roof PanelGable End PiecePanel Fastening ClipClosure Flashing BY OTHERSPainted Sheet Metal Tie ClipBase Polycarbonate Cill600Ridge Cover FlashingDanpalon PolycarbonateSheet (10mm Minimum)Closure FlashingBY OTHERSFastening ClipsDanpalon PolycarbonateDanpalon Polycarbonate<strong>Ondatherm</strong> <strong>900</strong> Roof PanelPolycarbonate U ChannelN° H011 - Rooflights 1 (Note: All installations should comply with the recommendations contained in MCRMA Techinical Papers N° 12 & 14; BS3200 and other relevant national standards)


NBS - H31<strong>Ondatherm</strong> <strong>900</strong> - <strong>roofing</strong>120A - Metal CladdingAccessoriesMatching flashings and support zeds.Fittings and accessories generally221 Accessories Cappings, closure pieces, flashings, trims cills, gutters, fillers, spacers, tapes, sealants, fixings etc, where notspecified, are to be types as recommended by ArcelorMittal - Arval.223 Isolating Tape A type recommended for the purpose by ArcelorMittal - Arval. Apply to those surfaces of supports whichwould otherwise be in contact with cladding or accessories after fixing.310A Purpose madecold formedmetalaccessoriesMaterial:Thickness/gauge:Finish/colour:Galvanized cold rolled steel sheet grade S220 GD.0.75mm minimum.External - Colorissime range.Internal - Interior 912Workmanship as NBS Standard Section Z22.RFix to <strong>Ondatherm</strong> /Structure with 4.8mm stitcher screws (or rivets) at <strong>900</strong>mm nominalcenters.Main panel fixingØ6.3 x 55 Ref A-10200Main panel fixingØ6.3 x 55 Ref A-10200Panel fastening plateSnap on cover plate Snap on cover plateTranslucent panelTranslucent panelBy othersPanel fasteningvariesvaries<strong>Ondatherm</strong> <strong>900</strong> roof panelMain panel fixingØ6.3 x 55 Ref A-10200Roof steelwork (purlin)Roof steelwork (purlin) <strong>Ondatherm</strong> <strong>900</strong> roof panelMain panel fixingØ6.3 x 55 Ref A-10200<strong>Ondatherm</strong> <strong>900</strong> roof panel Roof steelwork (purlin) Special translucent panel <strong>Ondatherm</strong> <strong>900</strong> roof panelBy othersPanel fasteningSnap on cover plate Snap on cover plateTranslucent PanelTranslucent PanelPanel fasteningVariesMake-up pieceVariesNote: These details are for guidance only.The individual building designer mustsatisfy him/herself of any and all coldbridging issues and adjust the finaldesign layout accordingly.<strong>Ondatherm</strong> <strong>900</strong> roof panelRoof steelwork (purlin)Roof steelwork (purlin) <strong>Ondatherm</strong> <strong>900</strong> roof panelN° H012 - Rooflights 2 (Note: All installations should comply with the recommendations contained in MCRMA Techinical Papers N° 12 & 14; BS3200 and other relevant national standards)


<strong>Ondatherm</strong> <strong>900</strong> - <strong>roofing</strong>120A - Metal CladdingAccessoriesMatching flashings and support zeds.Fittings and accessories generally221 Accessories Cappings, closure pieces, flashings, trims cills, gutters, fillers, spacers, tapes, sealants, fixings etc, where notspecified, are to be types as recommended by ArcelorMittal - Arval.223 Isolating Tape A type recommended for the purpose by ArcelorMittal - Arval. Apply to those surfaces of supports whichwould otherwise be in contact with cladding or accessories after fixing.310A Purpose madecold formedmetalaccessoriesMaterial:Thickness/gauge:Finish/colour:Galvanized cold rolled steel sheet grade S220 GD.0.75mm minimum.External - Colorissime range.Internal - Interior 912Workmanship as NBS Standard Section Z22.RFix to <strong>Ondatherm</strong> /Structure with 4.8mm stitcher screws (or rivets) at <strong>900</strong>mm nominalcenters or as required by penetration manufacturer.Flashing To Pre-FormedBase Unit BY OTHERS<strong>Ondatherm</strong> <strong>900</strong> Roof PanelMechanical ExtractBY OTHERSPre-Formed Closure PieceBY OTHERSNote: These details are for guidance only.The individual building designer mustsatisfy him/herself of any and all coldbridging issues and adjust the finaldesign layout accordingly.Preformed Base UnitBY OTHERS9 x 3mm ButylRubber SealantRoof Steelwork PurlinMechanical ExtractMODEL VELOCITY r.p.m. VOLUME m3/hHT-30HT-40HT-50HT-60HT-70HT-801.4501.4501.4501.4501.4501.4501.8004.6008.50014.00018.00026.200Flashing To Pre-FormedBase Unit BY OTHERS<strong>Ondatherm</strong> <strong>900</strong> Roof PanelDouble Flashing PieceBY OTHERSPre-Formed ClosurePiece BY OTHERSPreformed Base UnitBY OTHERS9 x 3mm ButylRubber SealantRoof Steelwork PurlinN° H013 - Penetrations (Note: All installations should comply with the recommendations contained in MCRMA Techinical Papers N° 12 & 14; BS3200 and other relevant national standards)


<strong>Ondatherm</strong> <strong>900</strong> - <strong>roofing</strong>120A - Metal CladdingAccessoriesFixing panels generallyMatching flashings and support zeds.R410 Fixing Panels The use of <strong>Ondatherm</strong> sandwich panels requires accurate setting out, with due allowance for buildingexpansion devices (these must not be built over).Before fitting the panels, the cladding contractor must inspect the supporting structure using thecriteria below listed, to ensure that the panels do not take on any uneveness inherent in the supportsupport system, thereby causing the finished surface of the facade to be out of true.The results of a bilateral inspection by the principal contractor and the supplier of the support systemshould be duly recorded in any inspection report.In case of complaint in respect of ArcelorMittal - Arval products we will require production of theinspection report for the support structure.Any roof panel system is aesthetically only as good as the framework to which it is fixed. It isessential therefore that the support system is true to line and plumb. We recommend that allRsecondary steelwork to which <strong>Ondatherm</strong> panels are fixed be designed to be capable of adjustmentduring erection. ArcelorMittal - Arval recommend steelwork tolerances as listed below:-Vertical tolerance (full height of building)Alignment (adjacent vertical supports)Horizontal tolerance (full length of building)= 5mm maximum= +/-2mm= +/-5mmR<strong>Ondatherm</strong> panels are purpose-made to specific requirements. Site cutting is not normally required,if cutting is required the following should be observed:-Before cutting, masking tape must be laid on the cutting line to protect coating from damage.Cutting must be carried out with a jigsaw, blades are to have fine metal cutting serrations.Note - Angle grinders or similar type tools must not be used.Cut panels on suitable supports to avoid de-lamination of metal skins by vibration.All exposed foam cut panel edges to be protected afterwards with self adhesive foil tape. Cut openingsin panels for outlets, vent pipes, flues, etc. to the minimum size necessary. Reinforce edges of openingswith support angles/flashings.Drill all holes and install fasteners perpendicular to the surface of the panels. Position the fasteners atregular intervals in straight lines, centred on the support bearings. Remove dust and any other foreignmatter before finally fixing panels into position.Protect panels adequately during fixing and up to Completion against mechanical damage/disfigurement.Rectify any defects as quickly as practicable to minimise damage and nuisance. Cladding panels andflashings must be cleaned down and swarf, rivet mandrels, debris, etc. must be removed on a day to daybasis as work proceeds.Paint all cut edges to match face finish.N° H014 - Fixing Generally (Note: All installations should comply with the recommendations contained in MCRMA Techinical Papers N° 12 & 14; BS3200 and other relevant national standards)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!