Pump Connections (General)22 mm copper inletpipework22 mm copper outletpipework.Integral pump isolating valveshown in ‘ON’ position.Suction supplyfrom tank withpush-in plumbingconnection.In the case of horizontal feeds use a22 mm <strong>com</strong>patible stem elbow (notsupplied). Do not bend the hosemore than 30° as they may be<strong>com</strong>edamaged, transmit noise or leak.22 mm flexiblepipes with push-inconnections, ensurethat connection isfully pushed homeinto hose end fitting and that hosesare kept as straight as possible.Isolating valve.Integral pump isolatingvalve shown in ‘OFF’position.Flexible hose.Flexible hose.30°Max.permittedflexiblehose bend.Suction supply from tankwith G ¾ male threadedpump connection.G ¾ running nut with captivesealing washer.Pressure switch.Inlet strainer housedin this location (seemaintenance section).Vent plug.G ¾ running nut withcaptive sealing washer.Delivery supply to shower/bathroomfitted with G ¾ male threaded pumpconnection.Flow switch.Pump body.Do not kink or twistthe hose.Anti-vibration foot.Fig. 11The pump should not be screwed down, ensure anti-vibration feet and flex hosesare used.Never operate pump with inlet and/or outlet isolating valves in the closedposition. Damage will occur!- 10 -