10.07.2015 Views

Monsoon Universal Single Installation Guide - Taps4Less.com

Monsoon Universal Single Installation Guide - Taps4Less.com

Monsoon Universal Single Installation Guide - Taps4Less.com

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

NOISEThe equivalent continuous A-weighted sound pressure level at a distance of 1 metrefrom the pump does not exceed 70 dB(A).TROUBLE SHOOTING GUIDESymptoms Probable Cause Re<strong>com</strong>mended ActionPump will not start. Electrical supply. Check wiring connections.Check all switches are ‘on’.Check fuse (see fuse section).Check circuit breaker is set.Faulty pressure switch.Turn off power. Release system water pressure.Turn on power, pump should start.If NOT refer to circuit test in Fig. 19 to confirm PCB operatingcorrectly.Faulty reed switch or PCB. Refer to circuit test as detailed in Fig. 19.Re<strong>com</strong>mended static inlet/outletheads exceeded.Internal motor thermotripactivated.Water starvation to pump.Re-position pump (see pump location section).Wait for thermotrip to auto-reset and check that duty point andrun time is within specification (see technical specification).Refer to ‘dry run protection’ section.No hot water. Air locked water feed. Vent hot water pump of air.Check cold feed to hot water cylinder.Check water level in cold water tank and that all stopcocksand isolating valves are open.Boiler is switched off.All hot water has been used.Faulty thermostatic mixer valve.Check boiler is switched ‘on’.Check cylinder thermostat.Check immersion heater.Check cylinder contains hot water.Check tank volume is adequate.Consult makers instructions.Pump starts when outlets are off. Leak in system. Check tap washers, w/c valve washers, pipe joints.orPump cycles (hunts) on/offfrequently.Pump runs on when all terminaloutlets are closed.Low pre-charge pressure inpressure vessel.Debris under non-return valvesealing face.Leak in system.Reed clamp out of positionFaulty reed switch, P.C.B orpressure switch.Jammed flow switch.Check pre-charge pressure in pressure vessel(see maintenance section).Run at full flow to try and flush away debris or remove, cleanor replace non-return valve.Check tap washers, w/c valve washers, pipe joints.Ensure reed clamp is fitted correctly in location groove(Fig. 19).If pump continues to run, this indicates a closed circuit ineither the flow switch reed, pressure switch or P.C.B. in theterminal box, these should be checked electrically.Isolate the pump electrically and hydraulically and removebrass housing that contains the float. Check float for freemovement.Reduced flow/performance. Blocked inlet strainers. Clean inlet strainers (see maintenance section).Blocked shower head sprayplate.Blocked pipework or pump.Clean in accordance with manufacturers instructions.Isolate pump electrically and hydraulically, locate blockageand remove.- 20 -

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!