TOTALPAC ® XDatasheet<strong>Firecycle</strong> ® <strong>III</strong> <strong>Deluge</strong> systemDESCRIPTIONThis TOTALPAC ® X integrated fire protection system byFireFlex Systems Inc. consists of a multicycling <strong>Firecycle</strong>® <strong>III</strong>deluge system trim totally pre-assembled, pre-wired andfactory tested. All electrical and mechanical components ofthe system are contained in one single unitTOTALPAC ® X multicycling deluge systems are built around theViking trim using flow control valves model H-3 for 1½" (40mm) diameter and model H-1 for 2" (50 mm) diameter andup.The <strong>Firecycle</strong>® <strong>III</strong> deluge system uses open type sprinklersand / or spray nozzles in the sprinkler piping which totallyflood an area with pressurized water. A detection network isused in parallel with the open type sprinkler / nozzles system.This network is electric and may be actuated by manual andrate-compensated temperature. When the detection systemoperates it gives an alarm and activates the Flow Controlvalve.In addition to automatically detecting a fire and turning thesystem on, <strong>Firecycle</strong>® <strong>III</strong> has the added ability to sense whenthe fire has been controlled, and automatically turn off thewater flow once a preprogrammed "Soak Timer" has beensatisfied. Should the fire rekindle, the control panel (suppliedby others) will initiate the sequence again. This unique<strong>Firecycle</strong>® <strong>III</strong> feature will repeat as long as power is availableto the panel, helping to minimize water usage, water damage,and the danger of pollution to surrounding areas.The <strong>Firecycle</strong>® <strong>III</strong> deluge system requires aVIKING VFR-400 control panel (supplied by others).All the valves are rated up to a maximum of 250 psi WWP(1724 kPa) max. and are available in the following diameters: 1½" (40 mm) 2" (50 mm) 3" (80 mm) 4" (100 mm) 6" (150 mm)Standard features• NEMA 3 or NEMA 4 construction• Easy and compact installation• Wide door for easy access• Quarter turn door latches• Lockable door to protect against tampering• Lifting lugs provided for safe and easy handling• Corrosion resistant paint finish• Water supply and drain through the bottom center ofthe unit to avoid freeze-up potential• Single drain connection• Serial number for easy referenceAvailable options• NEMA 3X or NEMA 4X, painted red stainless steelconstruction for corrosive environments• Insulated cabinet, with heater providing freezeprotection down to a temperature of 14°F (-10°C)• Low temperature sensor• Shut-off valve & sight glass• Door activated light kit1 of 10 FM-076D-0-27C


TOTALPAC ® XDatasheet<strong>Firecycle</strong> ® <strong>III</strong> <strong>Deluge</strong> systemStandard equipmentsFlow control valveThe Viking flow control valve is a quick opening, differentialtype flood valve with a spring loaded rolling diaphragmclapper. The flow control valve can be used to facilitatemanual or automatic on/off control. As an on/off controlvalve it may be used on deluge systems. The Viking flowcontrol valve is an integral part of the Viking <strong>Firecycle</strong>®System.Alarm pressure switchThe alarm pressure switch monitors the water flow withinthe sprinkler piping. Should the flow control valve clapperopens to allow water to flow into the sprinkler piping. Thealarm pressure switch will activate, indicating a water flowsignal.POTTERPS10-1ASolenoid valveThe high pressure solenoid valve is a two-way type withone inlet and one outlet. It is a packless, internal pilotoperated valve, suitable for use in releasing water pressurefrom the priming chamber of Viking deluge valves. Thesolenoid valve has floating diaphragm construction, whichrequires a minimum pressure drop across the valve tooperate properly.INOUT3 of 10 FM-076D-0-27C


TOTALPAC ® XDatasheet<strong>Firecycle</strong> ® <strong>III</strong> <strong>Deluge</strong> systemDetails & field wiring diagramsCabinet with main components, shown without doorFM-076Z-0-38A5 of 10 FM-076D-0-27C


TOTALPAC ® XDatasheet<strong>Firecycle</strong> ® <strong>III</strong> <strong>Deluge</strong> systemWiring diagramWaterflowAlarm switchTBA1234DFLTBBheater(optional)Light(optional)Main valveSup'v switch5678DFLFactory wiredN.C. solenoid valve(See table below for details)910111213DFLNOTES:- ALL DEVICES ARE SHOWN IN THEIRNORMAL SUPERVISORY STATE.- DRY CONTACTS RATINGS:PRESS. SWITCHES: 2.0A. 30VDC / 10A. 125/250 VACSUPV. SWITCHES: 0.5A. 125 VDC / .025A. 250 VAC / 10A 125/250VACUSE ONLY WITH POWER LIMITED CIRCUITSFactory wiredN.O. solenoid valve(See table below for details)Low temperatureSup'v switch(optional)Shut-off valveSup'v switch(optional)1415161718192021222324DFL DFL DFL- USE END-OF-LINE DEVICES COMPATIBLE WITH THERELEASE CONTROL PANEL USED (NOT INCLUDED).SOLENOID VALVE ELECTRICAL RATINGSViking P/N Description Voltage Watts DC AmpsPressureRating1159111596N.C.N.O.24 Vdc24 Vcc10 DC10 DC416mA416mA300 psi(2068 kPa)300 psi(2068 kPa)Notes:1. Solenoid Valve is UL Listed as Fire Protection Special System Water Control Release Service(UL 429A Product category VLTR).2. Voltage Drop: For proper operation, make sure that voltage at the solenoid valve is at least85% of nameplate rating.FM-076Z-0-34A7 of 10 FM-076D-0-27C


Datasheet<strong>Firecycle</strong> ® <strong>III</strong> <strong>Deluge</strong> systemTOTALPAC ® XDimensionsHBFACE VIEWSIDE VIEWA = Water inlet diameterB = Sprinkler riser diameterC = Drain diameterGDRAIN - SCH.40 GROOVED OUTLETCWATER INLETSCH.40 GROOVEDAEFDFM-076Z-0-54BNJBOTTOM VIEWMOTOP VIEWNNPP9/16" DIAM. (4 HOLES)PPFLOOR ANCHORING TEMPLATEDimensionsSystèmesA B C D E F G H J K L M N NN O P1.5" 2" 1.5" 2" 50" 23.5" 14" 74" 11.25" 10.75" 68" 25" 5.25" 24.5" 24.5" 12" 4.5"2" 2" 2" 2" 50" 23.75" 13" 74" 12" 11" 68" 25" 5.25" 24" 25" 11" 4.5"3" 4" 3" 2" 50" 23.5" 13.25" 74" 8.75" 11.5" 68" 25" 5.25" 21.5" 28" 10.5" 4.5"4" 4" 4" 2" 50" 13" 12.5" 74" 8" 12" 68" 25" 5.5" 24.5" 24.5" 12" 4.5"6" 6" 6" 2" 50" 22.75" 11.25" 74" 8.5" 12" 68" 25" 5.25" 24.5" 24.5" 12" 4.5"FM-076D-0-27C 8 of 10


TOTALPAC ® XDatasheet<strong>Firecycle</strong> ® <strong>III</strong> <strong>Deluge</strong> system9 of 10 FM-076D-0-27C


1935, Lionel-Bertrand Blvd.Boisbriand QC Canada J7H 1N8Tel.: 450-437-3473 • Fax: 450-437-1930Toll Free: 866-347-3353Email: info@fireflex.com • Web: www.fireflex.comFM-076D-0-27C 10 of 10