10.07.2015 Views

Doc Alfea S UK Sept. 2009.qxd:Mise en page 1 - Atlantic-comfort.com

Doc Alfea S UK Sept. 2009.qxd:Mise en page 1 - Atlantic-comfort.com

Doc Alfea S UK Sept. 2009.qxd:Mise en page 1 - Atlantic-comfort.com

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Doc</strong> <strong>Alfea</strong> S <strong>UK</strong> <strong>Sept</strong>. <strong>2009.qxd</strong>:<strong>Mise</strong> <strong>en</strong> <strong>page</strong> 1 18/09/09 16:36 Page 1AIR TO WATER HEAT PUMPSAlféa S InverterAlféa S Inverter6 models from 5 to 16 kWIndoor hydraulic moduleAir to Water heat pump• New application and boiler docking• Heating rate regulation directly controlsthe <strong>com</strong>pressor speed - V-PAM Inverter technology• Control of 2 heating circuits• Calorifier optional• COP ≥ 4Outdoor unit


<strong>Doc</strong> <strong>Alfea</strong> S <strong>UK</strong> <strong>Sept</strong>. <strong>2009.qxd</strong>:<strong>Mise</strong> <strong>en</strong> <strong>page</strong> 1 18/09/09 16:36 Page 2Alféa S: Air to Water inverterAlféa S hydraulic moduleThe Alféa S hydraulic module was developed and manufactured by <strong>Atlantic</strong> and from the very start wasdesigned to <strong>com</strong>bine performance, ergonomic design and modularity.Performance: with its pat<strong>en</strong>ted exchanger in a buffer tank and its regulation integrating the functionsto provide maximum <strong><strong>com</strong>fort</strong> for the user.Ergonomic design: with a securing bracket, integrated lifting bars; the hydraulic, refrigerating andelectronic connections are clearly distinguished to make installing and maintaining the appliance easier.Finally, modularity with the option fitting a boiler docking kit, a swimming pool kit, a cooling kit or ev<strong>en</strong>an Alféa S indirect water heater to meet all your requirem<strong>en</strong>ts.109Performance and <strong><strong>com</strong>fort</strong>Its <strong>com</strong>pactness and design is the perfect <strong>com</strong>plem<strong>en</strong>t to the highlevel of performance of the new Alféa S range:• Output from 5 to 15.5 kW – Single phase 230 V• Heating only (cooling is optional)• COP > 4 for the <strong>en</strong>tire range (water system 30/35°C and ext. T° 7°C)• Low noise level1New regulation withext<strong>en</strong>ded functions46328• 2 heating rate programming with 2 emission zones(2 underfloor zones or underfloor + radiator zones, etc...)• Hourly, daily, weekly programming of the heating• Load shedding for additional heaters is possible• Floor drying program• Swimming pool heating optional• Hot water managem<strong>en</strong>t with calorifier tank (optional)• Tarif managem<strong>en</strong>t1234557Electric cabinetController /User interfaceOn/off switchCirculator pump forthe heating systemHeating system flow678910Refrigerating fluidgas connectorPrimary circuit inletPressure gaugeExpansion vesselAutomatic drainOptimised transfer of heat witha pat<strong>en</strong>ted heat exchangerThe exchanger is immersed in the buffer tank to provide you withthe most advantages:• Low heat losses• Antifreeze is unnecessary• Not s<strong>en</strong>sitive to the loaded water• Resistance to fouling• Stainless steel buffer tank: no corrosion• Built-in additional electrical heater• Maint<strong>en</strong>ance cover in the upper section of the buffer tankOptional kits• 2 circuit cabinet featuring: regulation ext<strong>en</strong>sion, second zonemotorised valve, second zone circulator pump, separate cabinet,bush for moving the main circulator pump• Boiler docking kit featuring: directional valve, connection hose• Hot water kit featuring: directional valve, hot water s<strong>en</strong>sor• Swimming pool kit featuring: directional valve, swimming pools<strong>en</strong>sor, expansion unitDirect control of a systemwithout the need fora mixing valve


<strong>Doc</strong> <strong>Alfea</strong> S <strong>UK</strong> <strong>Sept</strong>. <strong>2009.qxd</strong>:<strong>Mise</strong> <strong>en</strong> <strong>page</strong> 1 18/09/09 16:36 Page 3providing optimum <strong><strong>com</strong>fort</strong>4035Compressormodulation3025Water flow T°Alféa outputInverter outdoor unit<strong>Alfea</strong> S provides the best in Inverter technology to<strong>com</strong>bine performance and <strong>en</strong>ergy savings. Theintegrated VPAM control governs the <strong>com</strong>pressor2019Outdoor T°-10Heating rate curveContinuous modulation of the<strong>com</strong>pressor speed 10 output stepsspeed of the unit to adapt the output of the heatpump continuously to the heating requirem<strong>en</strong>tsof the user.12345678910High-performance, low noise levelpropeller“Inverter” variable speed electric motor“Inverter” control modulePump down button and control diodeConnector terminals(power supply and interconnection)Refrigerating fluid storage cylinderCycle inversion valveAnti-corrosion treated metal coverHigh performance heat exchange surfaceevaporator; anti-corrosion, hydrophilicaluminium vanes, grooved copper tubesElectronic expansion valve111213Phonically and thermally insulated inverterscroll <strong>com</strong>pressorRefrigerating connection valves(flare connection) with protective coverDrip tank with cond<strong>en</strong>sate flow op<strong>en</strong>ingControl:VPAM inverter431296131110 kW model5710812DS VSM calorifier with 200 or 300 litres capacityConnected to the Alféa S, the DS VSM will provide the hot waterrequirem<strong>en</strong>ts of homes:• Capacity of 200 or 300 litres• New application and boiler docking• 3300 W built-in additional electrical heaterDim<strong>en</strong>sions:∅ H A B C D E FNetweightDS VS M 200 577 1270 446 446 543 465 - 645 73DS VS M 300 577 1787 490 490 587 489 - 645 94Hydraulic connection : primary circuit ∅ 1”F - secondary circuit ∅ 3/4”MUnderside viewAmazingly positive results on <strong>en</strong>ergy consumptionSignificant <strong>en</strong>ergy savings!Energy (kW/h)Énergie (kW/h)1500i1000500Free <strong>en</strong>ergyHeat pump <strong>en</strong>ergy consumption0-12-9-6-30369Température extérieure Outside temperature (°C)121518


<strong>Doc</strong> <strong>Alfea</strong> S <strong>UK</strong> <strong>Sept</strong>. <strong>2009.qxd</strong>:<strong>Mise</strong> <strong>en</strong> <strong>page</strong> 1 18/09/09 16:36 Page 4Technical characteristics and performancesUnits ALFEA S5 ALFEA S6 ALFEA S8 ALFEA S10 ALFEA S13 ALFEA S16Coolant type R410A R410A R410A R410A R410A R410AMAIN CHARACTERISTICSHeating capacity +7°C/+35°C – PCR W 5000 6500 8000 10300 12800 15500Input power +7°C/+35°C – PCR W 1160 1630 1880 2575 3120 3880COP +7°C/35°C - PCR 4,30 4,00 4,25 4,00 4,10 4,00Heating capacity -7°C/+35°C – PCR W 4800 5600 7000 8100 11000 13800Input power -7°C/+35°C – PCR W 1750 2240 2540 3520 3790 5300COP -7°C/+35°C - PCR 2,75 2,50 2,76 2,30 2,90 2,60Heating capacity +7°C/+45°C – BT radiators W 4150 5400 6200 8300 9700 13300Input power +7°C/+45°C – BT radiators W 1150 1610 1880 2515 3130 4090COP +7°C/45°C – BT Radiators 3,60 3,35 3,30 3,30 3,10 3,25Heating capacity -7°C/+45°C – BT radiators W 4050 5100 5900 7300 8300 11000Input power -7°C/+45°C – BT radiators W 1720 2320 2620 3475 4610 5370COP -7°C/+45°C – BT Radiators 2,35 2,20 2,25 2,10 1,80 2,05Addit. electrical heater in series W 2 x 1500 2 x 1500 2 x 1500 2 x 3000 2 x 3000 2 x 3000INDOOR HYDRAULIC MODULEDim<strong>en</strong>sions H x W x D mm 1000 x 450 x 480 1000 x 450 x 480 1000 x 450 x 480 1000 x 450 x 480 1000 x 450 x 480 1000 x 450 x 480Net weight/filled weight kg 52,5 / 77,5 52,5 / 77,5 52,5 / 77,5 52,5 / 77,5 52,5 / 77,5 52,5 / 77,5Hydraulic characteristicsBuffer tank capacity l 25 25 25 25 25 25Expansion vessel capacity l 8 8 8 8 8 8Heating system min./max. flow for 4°

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!