10.07.2015 Views

Model CP-5 - SymCom

Model CP-5 - SymCom

Model CP-5 - SymCom

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

FeaturesAdjustable 0 -10 minutetrip delay providesflexibility in applications.Bicolor LED indicatorlight is green in normalconditions and red duringtrip conditions.Adjustable trip level of 0-5A.10A @ 240VAC generalpurpose relay switchesloads on 115 and 240Vapplications.Microcontroller baseddesign provides betteraccuracy and higherreliability than analogdesigns.470VA @ 600 VAC relayswitches higher voltageloads on 480V systems.Three choices of inputvoltage ranges providethe versatility neededto handle globalapplications.<strong>Model</strong> <strong>CP</strong>-5 is an undercurrent monitor designed to monitor one leg of athree phase system. It is commonly used as a tower monitor on centerpivot irrigation systems to detect a stalled center pivot.<strong>Model</strong> <strong>CP</strong>-5•EngineeredProtection•MicrocontrollerBasedProtects 3-Phasemotors from:•Undercurrent conditionsStandard Features:•UL and cUL listed•5 year warranty•Made in USA•Adjustable 0-5A trip level•Adjustable 0-10 mintrip delay•Surface or DIN railmountableThe <strong>CP</strong>-5 has both an adjustable trip level and an adjustable trip delaytimer. When the current is sensed, the <strong>Model</strong> <strong>CP</strong>-5 activates its outputrelay, thus starting the motor/pump. When the current in the monitoredpower line falls below the user-selectable trip point, the output relay thengoes through the trip delay timer before finally deactivating the relay.2880 North Plaza Drive • Rapid City, SD 57702(800) 843-8848 • (605) 348-5580 • FAX (605) 348-5685www.symcominc.com • email: sales@symcominc.com6/04


IND. CONT. EQ.LISTED<strong>Model</strong> <strong>CP</strong>-5Specifications•Operating Points•Special OptionsSpecificationsInput Voltage . . . . . . . . . . . . . .115, 240, 480 VACFrequency . . . . . . . . . . . . . . . .50* or 60 HzOperating Points•Trip Level . . . . . . . . . . . . . . . . .0 - 5 Amps•Trip Delay . . . . . . . . . . . . . . . . .0 to 10 minutes•Restart . . . . . . . . . . . . . . . . . . .1.0 secondOutput Relay (SPDT)•Pilot Duty Contact Rating . . . . .470 VA @ 600 VAC (480V unit). . . . . . . . . . . . . . . . . . . . . . . . .480 VA @ 240 VAC (120 & 240V units)Weight . . . . . . . . . . . . . . . . . . .14 oz.*Note: 50 Hz will increase all delay timers by 20%.STATUSOKGREENTRIP DELAYBLINK REDSTATUSTRIPPEDRED784XTRIP DELAY (MIN)Pilot Duty Rating470VA at 600VACNCCT1MODEL <strong>CP</strong> - 5TOWER MONITORC4 62 80 10CT2L13.780" (96.01)4.500" (114.30)5.250" (133.35)460 VACL22 3140 5TRIP AMPSRapid City, SD0.060" (1.52)2.656"(67.46)D. 0.375"(9.53)2.973"(75.51)2.160"(54.86)<strong>SymCom</strong> warrants its microcontroller based products against defects in material or workmanship for a period offive (5) years from the date of manufacture. All other products manufactured by <strong>SymCom</strong> shall be warrantedagainst defects in material and workmanship for a period of two (2) years from the date of manufacture.For complete information on warranty, liability, terms, returns, and cancellations, please refer to the <strong>SymCom</strong>Terms and Conditions of Sale document.L1L2L3CENTERPIVOTPANELCT1L1L2CT2OLsMAG.COILPUMPCONTROLPOWERHANDSTOPOFFSTARTMAUTO2880 North Plaza Drive • Rapid City, SD 57702(800) 843-8848 • (605) 348-5580 • FAX (605) 348-5685www.symcominc.com • email: sales@symcominc.com6/04

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!