10.07.2015 Views

Guide to Construction of ArTu switchgear - Abb

Guide to Construction of ArTu switchgear - Abb

Guide to Construction of ArTu switchgear - Abb

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

5 Degrees <strong>of</strong> IK protection <strong>of</strong> the housings5.1 IK degree <strong>of</strong> protection <strong>of</strong> <strong>ArTu</strong> <strong>switchgear</strong>Characteristic LettersThe IK degree indicates the level <strong>of</strong> protection provided by the housing for the equipment againstharmful mechanical impacts, and is checked using standardised test methods.The IK code is the coding system for indicating the degree <strong>of</strong> protection provided by housingsagainst harmful mechanical impacts, in accordance with what is prescribed in the EN 50102Standard.The degree <strong>of</strong> protection <strong>of</strong> the housing against impacts is indicated by the IK code in thefollowing way:International mechanical protectionCharacteristic numerical group from 00 <strong>to</strong> 10IK 10Each characteristic numerical group represents an impact energy value as indicated in thetable:GENERALSTANDARDS ANDCHARACTERISTICSVERIFYING THEOVERTEMPERATURESRelationship between the IK degree <strong>of</strong> protection and impact energyCode IK IK00 IK01 IK02 IK03 IK04 IK05 IK06 IK07 IK08 IK09 IK10Joule impact energy (*) 0,14 0,2 0,35 0,5 0,7 1 2 5 10 20(*) Unprotected according <strong>to</strong> the following Standard.The degree <strong>of</strong> protection is normally applied <strong>to</strong> the complete housing. If parts <strong>of</strong> the housinghave different degrees <strong>of</strong> protection, the latter must be indicated separately.5.1 IK degree <strong>of</strong> protection <strong>of</strong> <strong>ArTu</strong> <strong>switchgear</strong>With regard <strong>to</strong> <strong>ArTu</strong> <strong>switchgear</strong>, the degree <strong>of</strong> IK protection is valid for the whole <strong>switchgear</strong>,mounted and installed as in ordinary use (with door closed).The degrees <strong>of</strong> protection against external mechanical impacts (IK code) <strong>of</strong> the <strong>ArTu</strong> series <strong>of</strong><strong>switchgear</strong> are given below.IK 08300mm1,7 kg<strong>ArTu</strong> LImpact energy inJoule 5,00PROTECTION AGAINSTSHORT-CIRCUIT ANDELECTRIC SHOCKSPRACTICAL INDICATIONSCERTIFICATION ANDCONSTRUCTIONIK 09With glazeddoor200mm5 kg<strong>ArTu</strong> M - KImpact energy inJoule 10,00CERTIFICATESIK 10With blinddoor400mm5 kg<strong>ArTu</strong> M - KImpact energy inJoule 20,00DECLARATION OFCONFORMITYABB SACE<strong>Guide</strong> <strong>to</strong> <strong>Construction</strong> <strong>of</strong> <strong>ArTu</strong> <strong>switchgear</strong>13

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!