8 Protection against the effects <strong>of</strong> short-circuit8.2 Short-circuit current and suitability <strong>of</strong> <strong>switchgear</strong> for the plantGENERALSTANDARDS ANDCHARACTERISTICSVERIFYING THEOVERTEMPERATURESPROTECTION AGAINSTSHORT-CIRCUIT ANDELECTRIC SHOCKSPRACTICAL INDICATIONSCERTIFICATION ANDCONSTRUCTIONCERTIFICATESDECLARATION OFCONFORMITYThe short-time short-circuit withstand current <strong>of</strong>the <strong>switchgear</strong> Icw (r.m.s. value) is knownYESIcc (prospective <strong>of</strong> the plant) < Icw(<strong>of</strong> the <strong>switchgear</strong>)YESSwitchgearsuitableThe following diagrams show the method <strong>to</strong> determine compatibility <strong>of</strong> the <strong>switchgear</strong> with the plant.ExampleExisting plant data:Vn=400 Vfn=50HzIcc=35kALet us suppose that in an existing plant there is electric <strong>switchgear</strong> with an Icw <strong>of</strong> 35kA andthat, in the installation point <strong>of</strong> the <strong>switchgear</strong>, the prospective short-circuit current is 35kA.Now let us imagine that it is decided <strong>to</strong> extend the power <strong>of</strong> the plant and that the short-circuitvalue increases <strong>to</strong> 60 kA.Plant data afterextension:NOThere is a circuit-breaker onthe supply side <strong>of</strong> the<strong>switchgear</strong> which for theprospective Icc has an I2t < I2t(<strong>of</strong> the <strong>switchgear</strong>) and a limitedpeak current Ip < Ip (<strong>switchgear</strong>)NOSwitchgearnot suitableIt must, <strong>of</strong> course, be checked that the breaking capacities <strong>of</strong> the apparatus inside the <strong>switchgear</strong> are compatible with theshort-circuit values <strong>of</strong> the plant.Vn=400 Vfn=50HzIcc=60kASince the <strong>switchgear</strong> Icw is lower than the short-circuit current <strong>of</strong> the plant, <strong>to</strong> check that theexisting <strong>switchgear</strong> is still compatible, you must:- determine the values <strong>of</strong> I 2 t and <strong>of</strong> Ip let through by the circuit-breaker placed on thesupply side <strong>of</strong> the <strong>switchgear</strong>- check that the protection devices located inside the <strong>switchgear</strong> have adequate breakingcapacity, individually or for back-up.Icw = 35kA from which:I 2 t <strong>switchgear</strong>= 35 2 x1 =1225 MA 2 sIp <strong>switchgear</strong>= 73.5 kALet us suppose that, on the supply side <strong>of</strong> the <strong>switchgear</strong>, a Tmax T5H moulded-case circuit-breaker(Icu=70kA@415V) is installedI 2 t interrut<strong>to</strong>re< 4MA 2 sIp interrut<strong>to</strong>re I 2 t <strong>switchgear</strong>Ip circuit-breaker> Ip <strong>switchgear</strong>The conditioned short-circuit current <strong>of</strong> the <strong>switchgear</strong>(r.m.s. value) is knownIcc (prospective <strong>of</strong> the plant) < Icc (conditioned <strong>of</strong> the<strong>switchgear</strong>) (with a specifiedprotection device)YESSwitchgearsuitableThe <strong>switchgear</strong> (structure and busbar system) turns out <strong>to</strong> be suitable.With regard <strong>to</strong> the circuit-breakers located inside the <strong>switchgear</strong>, let us suppose that theseare Tmax T1,T2,T3 moulded-case circuit-breakers, version N with Icu=36kA@415V. From theBack-up tables it can be seen that the circuit-breakers present in the <strong>switchgear</strong> are suitablefor the plant as their breaking capacity is increased <strong>to</strong> 65 kA by the T5H circuit-breaker placedon the supply side.NOSwitchgearnot suitable46 ABB SACE<strong>Guide</strong> <strong>to</strong> <strong>Construction</strong> <strong>of</strong> <strong>ArTu</strong> <strong>switchgear</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!