10.07.2015 Views

Guide to Construction of ArTu switchgear - Abb

Guide to Construction of ArTu switchgear - Abb

Guide to Construction of ArTu switchgear - Abb

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

2 Rated electric characteristics <strong>of</strong> <strong>switchgear</strong>Maximum ratedoperatingvoltage value<strong>to</strong>wardsearth in AC(r.m.s. value)or DC[V]501001503006001000Alternating current(r.m.s. value)AC r.m.s.–66/115120/208127/220230/380; 230/400;240/415; 260/440;277/480347/600; 380/660;400/690; 415/720;480/830–Correspondence between the rated voltage <strong>of</strong> the power supply system and therated impulse withstand voltage, in the case <strong>of</strong> protection against overvoltageswith surge arresters conforming <strong>to</strong> IEC 60099-1Rated voltage <strong>of</strong> the power supply system(≤<strong>of</strong> the rated insulation voltage <strong>of</strong> the equipment)[V]Alternating current(r.m.s. value)AC r.m.s.–66115; 120;127220; 230240; 260277347; 380; 400415; 440; 480500; 577; 600660;690; 720;830; 1000Alternating current(r.m.s. value) ordirect currentAC r.m.s. or DC12,5; 24; 2530; 42; 4860110; 1202204801000Alternating current(r.m.s. value) ordirect currentAC r.m.s. or DC–220-110240-120440-220960-480–Preferential values <strong>of</strong> the ratedimpulse withstand voltage [kV](1.2 / 50 ms) at 2000 mIV III II IInitial installationlevel(operatinginput)Overvoltage categoryInitialdistributioncircuit levelLoadlevelProtectedlevelThe values <strong>of</strong> rated impulse withstand voltage provided in the table are based on the operating characteristics <strong>of</strong> the surge arresters in accordancewith IEC 60099-1.For cases where control <strong>of</strong> the overvoltages is obtained by means other than by surge arresters, IEC 60364-4-443 provides the informationabout correlation between the rated voltage <strong>of</strong> the power supply system and the rated impulse withstand voltage <strong>of</strong> the equipment.1,52,5468120,81,52,54680,50,81,52,5460,330,50,81,52,54GENERALSTANDARDS ANDCHARACTERISTICSVERIFYING THEOVERTEMPERATURESPROTECTION AGAINSTSHORT-CIRCUIT ANDELECTRIC SHOCKSPRACTICAL INDICATIONSCERTIFICATION ANDCONSTRUCTIONDECLARATION OFCONFORMITYCERTIFICATESABB SACE<strong>Guide</strong> <strong>to</strong> <strong>Construction</strong> <strong>of</strong> <strong>ArTu</strong> <strong>switchgear</strong>5

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!