7 Checking the overtemperature limits inside <strong>ArTu</strong><strong>switchgear</strong>7.3 Checking procedureIncoming and outgoing <strong>switchgear</strong> cablesThe power dissipated by the pieces <strong>of</strong> cable which enter the <strong>switchgear</strong> must be countedseparately.In some cases, the variability in length <strong>of</strong> these pieces causes their power <strong>to</strong> be negligible,whereas in others it is decisive for correct calculation <strong>of</strong> the dissipated power inside the<strong>switchgear</strong>.The power dissipated by them can be calculated by means <strong>of</strong> the following relation:2IP (I b ) = P (I n )(b. LI n)piece. 3Where:P (I n) is the dissipated power per unit <strong>of</strong> length at the rated current and the its value canbe taken from table B1 <strong>of</strong> the IEC 60890 Standard given below, or from the manufacturer’scatalogues.(L piece. 3) is the length <strong>of</strong> the piece <strong>of</strong> cable inside the <strong>switchgear</strong> or <strong>of</strong> the column beingexamined, multiplied by 3 as it is a three-phase circuit. This length can be calculatedapproximately by inspecting the front <strong>of</strong> the <strong>switchgear</strong>.Table B1 <strong>of</strong> the IEC 60890 Standard was used for the calculations in this document, consideringan air temperature <strong>of</strong> 55°C around the cable.Operating current and dissipated powers <strong>of</strong> the insulated conduc<strong>to</strong>rsCrosssection(Cu)Maximum admissible temperature <strong>of</strong> the conduc<strong>to</strong>r: 70 °C(1)d d d dAir temperature around the conduc<strong>to</strong>rs inside the housingGENERALSTANDARDS ANDCHARACTERISTICSVERIFYING THEOVERTEMPERATURESPROTECTION AGAINSTSHORT-CIRCUIT ANDELECTRIC SHOCKSoperating current35 °C 55 °C 35 °C 55 °C 35 °C 55 °Cdissipatedpowers (2)mm 2 A W/m A W/m A W/m A W/m A W/m A W/m1,52,546101625355070951201501852403001217222838522,12,52,62,83,03,7operating current81114182534dissipatedpowers (2)0,91,11,11,21,31,6operating current12202532486485104130161192226275295347400dissipatedpowers (2)2,13,53,43,74,85,66,37,57,98,48,79,611,710,912,013,2812182331425567851051251471671912252600,91,31,81,92,02,42,63,13,43,63,74,14,34,65,05,6122025325065851151501752252502753504004602,13,53,43,75,25,86,37,910,59,911,911,711,715,415,917,5(1) Each desired layout, with the specific values, refers <strong>to</strong> a group <strong>of</strong> conduc<strong>to</strong>rs gathered <strong>to</strong>gether in a bundle (sixconduc<strong>to</strong>rs loaded at 100%)(2) Single lengthoperating currentdissipatedpowers (2)operating currentdissipatedpowers (2)operating current812202532506585115149175210239273322371dissipatedpowers (2)0,91,32,22,32,13,43,75,06,27,27,28,38,89,410,311,4PRACTICAL INDICATIONSCERTIFICATION ANDCONSTRUCTIONCERTIFICATESDECLARATION OFCONFORMITYABB SACE <strong>Guide</strong> <strong>to</strong> <strong>Construction</strong> <strong>of</strong> <strong>ArTu</strong> <strong>switchgear</strong> 21

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!