3 Classification <strong>of</strong> electric <strong>switchgear</strong>3.1 Open <strong>switchgear</strong> and closed <strong>switchgear</strong> - 3.2 External configuration- 3.3 Installation conditionsThere are different classifications for electric <strong>switchgear</strong>, which depend on various fac<strong>to</strong>rs:on the type <strong>of</strong> construction, on external configuration, on installation conditions and on thefunction carried out.3.1 Open <strong>switchgear</strong> and closed <strong>switchgear</strong>According <strong>to</strong> the type <strong>of</strong> construction, the IEC 60439-1 Standard first <strong>of</strong> all distinguishesbetween open and closed <strong>switchgear</strong>.- ClosedThe <strong>switchgear</strong> is closed when it includes panels protected on all sides <strong>to</strong> guarantee adegree <strong>of</strong> protection against direct contacts not less than IPXXB (see chapter 4). The<strong>switchgear</strong> used in ordinary environments must be closed.- OpenOpen <strong>switchgear</strong>, with or without front protection, are the so-called open <strong>switchgear</strong>,where live parts are accessible. This <strong>switchgear</strong> can only be used in electricalworkshops, i.e. in places where trained personnel have access.3.2 External configurationFrom the viewpoint <strong>of</strong> external configuration, the <strong>switchgear</strong> is distinguished by being:- With cabinet (column)Used for large distribution and control apparatus. By placing several cabinets side byside <strong>switchgear</strong> with multiple cabins is obtained.- With benchUsed for controlling machines or complex plants both in the mechanical industry sec<strong>to</strong>rand in those <strong>of</strong> the iron and steel or chemical industries.- With boxCharacterized by wall mounting both extending and embedded. This <strong>switchgear</strong> isused for distribution at department or zone level in industrial and service sec<strong>to</strong>r environments.- With multiple boxesEach box, usually <strong>of</strong> the protected type and with release flanges, contains a functionalunit which can be an au<strong>to</strong>matic circuit-breaker, a starter, or a socket complete withcircuit-breaker lock or protection.3.3 Installation conditionsFrom the viewpoint <strong>of</strong> the installation conditions, the <strong>switchgear</strong> is distinguished by:- Switchgear for indoor useSwitchgear intended <strong>to</strong> be used in rooms where there are normal operating conditionsfor indoor use, as specified in 6.1 <strong>of</strong> IEC 60439-1, i.e.:Environmental installation conditions for indoor useRelative humidity Air temperature Altitude0% (at a maximum temperature <strong>of</strong> 40° C)90% (at a maximum temperature <strong>of</strong> 20° C)Maximum temperature ≤40° CMaximum average temperature over a period <strong>of</strong> 24 hours ≤35° CMinimum temperature ≥ -5° CNot above2000 m- Switchgear for outdoorsSwitchgear intended for use under normal operating conditions for outdoor installations,as specified in 6.1 <strong>of</strong> IEC 60439-1, i.e.:Environmental installation for outdoor conditionsRelative humidity Air temperature Altitude100% temporarily(at a maximum temperature <strong>of</strong> 25° C)Maximum temperature ≤40° CMaximum average temperature over a period <strong>of</strong> 24 hours ≤35° CMinimum temperature ≥-25° C for temperate climatesMinimum temperature ≥-50° C for arctic climatesNot above2000 m- Fixed <strong>switchgear</strong>Switchgear intended <strong>to</strong> be fixed on the installation site, for example on the floor or ona wall and <strong>to</strong> be used in that place.- Moveable <strong>switchgear</strong>Switchgear intended <strong>to</strong> be easily moved from one place <strong>of</strong> use <strong>to</strong> another.GENERALSTANDARDS ANDCHARACTERISTICSVERIFYING THEOVERTEMPERATURESPROTECTION AGAINSTSHORT-CIRCUIT ANDELECTRIC SHOCKSPRACTICAL INDICATIONSCERTIFICATION ANDCONSTRUCTIONCERTIFICATESDECLARATION OFCONFORMITYABB SACE<strong>Guide</strong> <strong>to</strong> <strong>Construction</strong> <strong>of</strong> <strong>ArTu</strong> <strong>switchgear</strong>7

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!