11.07.2015 Views

Measuring Gas Velocity with the D-FL 100 Differential Pressure Bar

Measuring Gas Velocity with the D-FL 100 Differential Pressure Bar

Measuring Gas Velocity with the D-FL 100 Differential Pressure Bar

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

D−<strong>FL</strong> <strong>100</strong> Seite 205. Start-Up / Error Messages5.1. Start-up of <strong>the</strong> TransducerThe differential pressure bar is equipped standard <strong>with</strong> a differential pressure transducer 2010TD madeby ABB <strong>with</strong>out a display.The transducer will be shipped adjusted (* by Durag. After mounting <strong>the</strong> transmitter it is only necessaryto do a zero point adjustment.1) turn <strong>the</strong> switching valve to <strong>the</strong> position zero point adjustment2) open exhaust screws and wait 30 sec.3) open <strong>the</strong> key-cover on <strong>the</strong> top of <strong>the</strong> transducer4) press down <strong>the</strong> lock-key „ / M“ <strong>with</strong> a screwdriver and turn it 90°5) press <strong>the</strong> „0% / -“ key once6) turn back <strong>the</strong> lock-key to lock <strong>the</strong> transducerNow <strong>the</strong> transducer is adjusted ans should be readout 4mA.If you want to change <strong>the</strong> measuring range <strong>the</strong>re are three possibilities:• 1) open <strong>the</strong> key-cover on <strong>the</strong> top of <strong>the</strong> transducer2) press down <strong>the</strong> lock-key „ / M“ <strong>with</strong> a screwdriver and turn it 90°3) connect a definied pressure for <strong>the</strong> beginning of <strong>the</strong> measuring range (normaly 0 mbar) andwait 30s for stabilisation4) press <strong>the</strong> „0% / -“ Key once5) connect pressure for <strong>the</strong> end of <strong>the</strong> measuring range and wait 30s for stabilisation6) press <strong>the</strong> „<strong>100</strong>% / +“ Key once7) turn back <strong>the</strong> lock-key to lock <strong>the</strong> transducer• It is possible to order a LC-display <strong>with</strong> two additional keys. With this display you can change veryparameter of <strong>the</strong> transducer.• The transducers have a HART-interface for programming <strong>the</strong> parametersNote: you have to change <strong>the</strong> parameter of your evaluation unit (D-<strong>FL</strong><strong>100</strong>-10) also.(* measuring range see chapter 9.1; damping 5s; transfer function: rootGmbH

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!