11.07.2015 Views

Measuring Gas Velocity with the D-FL 100 Differential Pressure Bar

Measuring Gas Velocity with the D-FL 100 Differential Pressure Bar

Measuring Gas Velocity with the D-FL 100 Differential Pressure Bar

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

D−<strong>FL</strong> <strong>100</strong> Seite 247. MaintenanceThe D-<strong>FL</strong> <strong>100</strong> is a low-maintenance system <strong>with</strong> long maintenance intervals. The maintenance scheduledepends on <strong>the</strong> application, and is generally several months (3 months as a rule of thumb). <strong>Pressure</strong>conditions, climatic and o<strong>the</strong>r ambient influences at <strong>the</strong> measuring site, and <strong>the</strong> gas being measured allaffect <strong>the</strong> maintenance schedule.Maintenance work should be performed in <strong>the</strong> following order:1. Adjust menu item Maintenance at <strong>the</strong> D-<strong>FL</strong> <strong>100</strong>-10 Display.Use <strong>the</strong> MOD key on <strong>the</strong> D-<strong>FL</strong> <strong>100</strong>-10 Display to select Stand by.2. Clean <strong>the</strong> exterior of <strong>the</strong> unit.3. Check <strong>the</strong> differential pressure bar and <strong>the</strong> differential pressure transducer.Check exterior covers and <strong>the</strong> connections between differential pre ssure bar and transducer.4. Flush <strong>the</strong> measuring pipes.The pipes may need to be flushed, depending on application conditions. By changing <strong>the</strong> setting of<strong>the</strong> switching valve, purge air is directed separately to <strong>the</strong> different pressure lines (see Fig. 4 forswitching valve settings).5. Clean <strong>the</strong> differential pressure bar.Under extreme application conditions, when a simple flushing of <strong>the</strong> pressure lines would not besufficient, <strong>the</strong> differential pressure bar must be cleaned <strong>with</strong> a cloth or a brush. The differentialpressure bar must first be disconnected from <strong>the</strong> transducer and removed from <strong>the</strong> duct/stack. Themaintenance intervals need to be shorter under such extreme application conditions.6. Make a zero point adjustment of <strong>the</strong> differential pressure transducer.The two wires on <strong>the</strong> transducer are cross-wired via <strong>the</strong> switching valve, and <strong>the</strong> exhaust screwsare opened briefly and shut again (pressure equalization at transducer).Remove <strong>the</strong> housing cover from <strong>the</strong> transducer to monitor <strong>the</strong> electric current signal on <strong>the</strong> display.The current output must now be 4.00 mA. If it is not, a zero point adjustment must be made.Remove both screws from <strong>the</strong> protective cover and remove <strong>the</strong> cover. Use <strong>the</strong> M key to proceed topoint 7 and perform <strong>the</strong> adjustment. Press and simultaneously for about 2 seconds. Thedisplay should now show 4.00 mA; if it does not, repeat <strong>the</strong> adjustment.7. Switch on <strong>the</strong> D-<strong>FL</strong> <strong>100</strong>-10 Display.Use <strong>the</strong> MOD key on <strong>the</strong> D-<strong>FL</strong> <strong>100</strong>-10 Display to proceed <strong>with</strong> <strong>the</strong> measuring process.GmbH

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!