11.07.2015 Views

TB7220 Ultrastat Programmable Thermostat - The Energy Conscious

TB7220 Ultrastat Programmable Thermostat - The Energy Conscious

TB7220 Ultrastat Programmable Thermostat - The Energy Conscious

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>TB7220</strong> ULTRASTAT PROGRAMMABLE THERMOSTATInstallerSetupNumber0640 a Clock Format 12 12—12 Hour24—24 Hour0650 Extended FanOn time Heat0660 Extended FanOn time Cool0 0—Off90—90 seconds0 0—Off40—40 seconds0670 Keypad Lockout 0 0—Unlocked1—Partial Lockout 12—Partial Lockout 23—Fully Locked0680 Temperature ControlHeat0685 Recovery HeatRamp Rate0690 Temperature ControlCool0695 Recovery CoolRamp Rate0700 Temperature DisplayOffset0710 Restore FactoryDefaults2 1—Less Aggressive2—Standard3—More AggressiveNot displayed with fan set to fossil or with cool-onlysystemsOnly shown if system has cool stages.Unlocked: All functions accessible.Partial 1: Locks all but Holiday, Override, and Up/Down.Partial 2: Locks all but Holiday and Override.Full: Entire interface locked/non-functional.Only shown if system has heat stages.Only integral gains affected. Affects control operation in allcontrol regimes (not just recovery or setpoint change).More Aggressive stops signal prior to reaching the setpoint.(For use with oversized equipment.)5 0-20°F/hour Only shown if system has heat stages.0 disables ramped recovery (step setpoint change at periodstart time)2 1—Less Aggressive2—Standard3—More AggressiveOnly shown if system has cool stages.Only integral gains affected. Affects control operation in allcontrol regimes (not just recovery or setpoint change).More Aggressive stops signal prior to reaching the setpoint.(For use with oversized equipment.)3 0-20°F/hour Only shown if system has cool stages.0 disables ramped recovery (step setpoint change at periodstart time)0 -3 (-1.5)— -3°F (-1.5°C)-2 (-1.0)— -2°F (-1.0°C)-1 (-0.5)— -1°F (-0.5°C)0 (0.0)—0°F (0.0°C)1 (0.5)—1°F (0.5°C)2 (1.0)— 2°F (1.0°C)3 (1.5)—3°F (1.5°C)0 0—No1—YesINSTALLER SYSTEM TEST ITEMSTest 1 Installer TestCool0 0—Off1—Cool Stage 12—Cool Stage 2Test 2Test 3Test 4Installer SetupNameInstaller TestFanInstaller TestHeatInstaller TestAuxiliary HeatTable 6. Installer Setup Menu. (Continued)DefaultSetting All Settings Notes0 0—Off1—Fan On0 0—Off1—Heat Stage 12—Heat Stage 1 and 23—Heat Stage 1,2 and 30 0—Auxiliary Heat Off1—Auxiliary Heat Ona Setting available for modification in both the Installer and User setup modes.This offset applies to both the control temperature and tothe display temperature for indoor sensor (and remoteindoor sensor)Resets all Installer Setup parameters to default values andresets the schedule to default. Retains only calendarsettings and time.NOTE:Press the Done button to exit the Installer System Test.15 63-2636—03

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!