11.07.2015 Views

TB7220 Ultrastat Programmable Thermostat - The Energy Conscious

TB7220 Ultrastat Programmable Thermostat - The Energy Conscious

TB7220 Ultrastat Programmable Thermostat - The Energy Conscious

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>TB7220</strong> ULTRASTAT PROGRAMMABLE THERMOSTATMAIN SCREENDOWN BUTTONLOWERS TEMPERATURE SETTING ORMAKES SELECTIONS IN OTHER SCREENSUP ARROW BUTTONRAISES TEMPERATURE SETTING ORMAKES SELECTIONS IN OTHER SCREENSSYSTEM & FAN BUTTONSELECTS FAN AUTO OR ONSELECTS HEAT, OFF, COOLAND EM HEATSHOWS CURRENTDAY OF WEEKSystemCoolFan AutoSystem & Fan Schedule Clock & MoreCLOCK &MORE BUTTONSELECTS TIME ANDFURNACE FILTERINFORMATIONFig. 34. Main screen selections.MonSCHEDULE BUTTONSELECTS PROGRAMMINGMODESystem Auto Fan AutoCURRENTTIMESet ToAux Heat OnSystem & Fan Schedule Clock & MoreTEMPERATURESETTINGM24108PROGRAMMINGTable 7 shows default program settings.Table 7. <strong>Energy</strong>-saving Default Program Settings.ScheduleSetpointsPeriod Time HeatCoolOcc1 8:00am 70°F (21°C) 75°F (24°C)Unocc1 10:00pm 55°F (10°C) 85°F (29.5°C)Occ2 — — —Unocc2 — — —Fan SettingsAuto: Fan runs only when heating/cooling system is on.See the Fan Schedule section for more information.On: Fan runs continuously.System SettingsHeat: <strong><strong>The</strong>rmostat</strong> controls the heating system.Off: Both heating and cooling systems are off.Cool: <strong><strong>The</strong>rmostat</strong> controls the cooling system.Auto: <strong><strong>The</strong>rmostat</strong> automatically changes between heat andcool operation, depending on indoor temperature.Programming Heating and Cooling Schedule<strong>The</strong> thermostat can control up to four different scheduleperiods per day:OCC 1: Work arrival time. Period to keep space at acomfortable temperature.UNOCC1: Work exit time. Period to keep space at anenergy-saving temperature.OCC 2: Second occupied period.UNOCC2: Second unoccupied period.NOTE:Available schedule times are at 15-minute intervals.Editing Schedule1. Press MORE2. Press SCHEDULE.3. Press EDIT.4. Press SELECT DAY to select the days you wish toschedule.5. Press NEXT when finished selecting daysCURRENTSYSTEM SETTINGCURRENTFAN SETTINGINDICATESTHERMOSTAT IS"CALLING FORCOOL OR HEAT"M24109NOTES:— Multiple days can be selected.— To skip over a day, press the Up or Down arrowkeys.— Checkmarks appear next to selected days. <strong>The</strong>seare scheduled with identical times and temperatures.Fig. 35. Main screen display.63-2636—03 16

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!