SINGLE PIPES 3:106Curved pipes<strong>Series</strong> 1, 2, 3 <strong>and</strong> 4deflectionPN 16/PN25CURVED PIPES 1123, 1124, 1223, 1224, 1323, 1324, 1423, 1424Single pipesMax. deflectionDN L = 12 m L = 16 m Note25 - 80 35 o To be bent at installation site80 - 100 35 o Bent at <strong>Powerpipe</strong> works125 - 150 30 o 25 o Bent at <strong>Powerpipe</strong> works200 25 o 33 o Bent at <strong>Powerpipe</strong> works250 25 o 33 o Bent at <strong>Powerpipe</strong> works300 20 o 25 o Bent at <strong>Powerpipe</strong> works350 14 o 23 o Bent at <strong>Powerpipe</strong> works400 11-(18) o 15-(22) o Bent at <strong>Powerpipe</strong> works *450 7-(11) o 11-(18) o Bent at <strong>Powerpipe</strong> works *500 5-(9) o 8-(12) o Bent at <strong>Powerpipe</strong> works *600 – 8 o Bent at <strong>Powerpipe</strong> works*700 – 4 o Bent at <strong>Powerpipe</strong> works** See note below concerning wall thickness. wall thickness below. In paranteses; the specified values relatesthickness higher than st<strong>and</strong>ard.Accuracy of manufacture DN 100 - 200 +/- 2°DN 250 - 600 +/- 1°Steel pipes:For the manufacturing either seamless steel pipes or longitudinally welded steel pipes are used.DN 450, DN 500, DN 600 <strong>and</strong> DN700 steel pipes with extra wall thickness will be used. Increasedwall thickness for smaller dimensions will allow deflection exceeding above normal max. deflection.This can be delivered on request. However, this means increased prices <strong>and</strong> longer deliverytime. For larger sizes (DN700-900) segment-welded curved pipes can be offered.For manufacturing technical reasons, the alarm wires placed in neutral position, ie c. at. 12 <strong>and</strong> 6.Article no. series 11123-DN-xxx-000 for 12 m pipe length1124-DN-xxx-000 for 16 m pipe lengthArticle no. series 21223-DN-xxx-000 for 12 m pipe length1224-DN-xxx-000 for 16 m pipe lengthArticle no. series 31323-DN-xxx-000 for 12 m pipe length1324-DN-xxx-000 for 16 m pipe lengthArticle no. series 41423-DN-xxx-000 for 12 m pipe length1424-DN-xxx-000 for 16 m pipe lengthxxx = degreesAn example of how to order:Curved pipe series 1, L = 12 m with dim DN 200 <strong>and</strong> curved 15 ohas Article No. 1123-200-015-000, Deflection shall be stated in a separate line of text.Edition 2013
SINGLE PIPES 3:107Curved pipes - HorizontalDeflection versus designradius<strong>Series</strong> 1, 2, 3 <strong>and</strong> 4PN 16/PN25Design radiusLengthDeflectionCORRELATION BETWEEN DEFLECTION AND DESIGN RADIUSDesign radiusDesign radiusDeflection L = 12 m L = 16 m Deflection L = 12 m L = 16 m1° 690 910 21° 33,0 44,02° 345 460 22° 31,0 42,03° 230 305 23° 30,0 40,04° 170 230 24° 29,0 38,05° 140 185 25° 28,0 37,06° 115 155 26° 27,0 36,07° 98 130 27° 26,0 34,08° 86 115 28° 25,0 33,09° 76 100 29° 24,0 32,010° 69 92 30° 23,2 30,911° 62 83 31° 22,5 30,012° 57 76 32° 21,8 29,113° 53 71 33° 21,1 28,114° 49 65 34° 20,5 27,315° 46 61 35° 20,0 26,716° 43 57 36° 19,4 25,817° 40 54 37° 18,9 25,218° 38 51 38° 18,4 24,619° 36 48 39° 18,0 23,920° 34 46 40° 17,5 23,4Pipe trench:A pre-insulated pipe DN>250 cannot be bent along its entire length. At each pipe end astraight part will remain, which shall be approximately 2 meters in length.This deviation from an ideal curved pipe radius is to be compensated when installing the pipeby making the pipe trench approximately 150 mm wider.The widening should be ~200 mm at deviation < 10 oThe widening should be ~500 mm at deviation > 10 oEdition 2013
- Page 1: INDEXGeneralinformationTechnology,q
- Page 4 and 5: Technology, Quality and Environment
- Page 6 and 7: Technology, Quality and Environment
- Page 8 and 9: Technology, Quality and Environment
- Page 10 and 11: SINGLE PIPES 3:102Straight pipesSer
- Page 12 and 13: SINGLE PIPES 3:104Straight pipesSer
- Page 16 and 17: SINGLE PIPES 3:108Curved pipesElast
- Page 18 and 19: SINGLE PIPES 3:202Termination bend
- Page 20 and 21: L3L2SINGLE PIPES 3:302T-piece withe
- Page 22 and 23: SINGLE PIPES 3:304T-pieces withpara
- Page 24 and 25: SINGLE PIPES 3:401ValvesSeries 1, 2
- Page 26 and 27: SINGLE PIPES 3:403Valve with double
- Page 28 and 29: DesignSINGLE PIPES 3:405Valve with
- Page 30 and 31: Model BSINGLE PIPES 3:407Combinatio
- Page 32 and 33: SINGLE PIPES 3:501Anchor unitstSeri
- Page 34 and 35: SINGLE PIPES 3:503Reduction unitThe
- Page 36 and 37: DOUBLE PIPES 4:102Straight pipes,do
- Page 38 and 39: DOUBLE PIPES 4:104Straight pipes fo
- Page 40 and 41: DOUBLE PIPES 4:106Curved pipesDefle
- Page 42 and 43: DOUBLE PIPES 4:201BendHorizontalPN
- Page 44 and 45: DOUBLE PIPES 4:203Termination bend
- Page 46 and 47: DOUBLE PIPES 4:205Bend out of plane
- Page 48 and 49: DOUBLE PIPES 4:302Intersection unit
- Page 50 and 51: DOUBLE PIPES 4:304T-piece Double/si
- Page 52 and 53: DOUBLE PIPES 4:306Transition unit s
- Page 54 and 55: DOUBLE PIPES 4:402BValve unit,Compa
- Page 56 and 57: DOUBLE PIPES 4:404200Air release/ d
- Page 58 and 59: DOUBLE PIPES 4:406Combination valve
- Page 60 and 61: DOUBLE PIPES 4:408DpHValve unit wit
- Page 62 and 63: DOUBLE PIPES 4:502Anchor unittThe a
- Page 64 and 65:
SPECIAL PIPES 5:101District cooling
- Page 66 and 67:
SPECIAL PIPES 5:201High temperature
- Page 68 and 69:
SPECIAL PIPES 5:203High temperature
- Page 70 and 71:
SPECIAL PIPES 5:205High temperature
- Page 72 and 73:
SPECIAL PIPES 5:302Bend with spiroa
- Page 74 and 75:
District heating for small houses 5
- Page 76 and 77:
Laying of steel- and copper pipes 5
- Page 78 and 79:
Type section for flexible pipes 5:4
- Page 80 and 81:
Flexpipe, copper 5:502Flexible pipe
- Page 82 and 83:
JOINTS 6:101OverviewWelding jointA
- Page 84:
JOINTS 6:103Welding joint,shrinkabl
- Page 87 and 88:
JOINTS 6:203Heat-shrinkablesleeve,P
- Page 89 and 90:
JOINTS 6:205Double sealedExtended s
- Page 91 and 92:
JOINTS 6:207Double sealedTerminatio
- Page 93 and 94:
JOINTS 6:301Tubular and openshrinki
- Page 95 and 96:
JOINTS 6:401Hot tapping T-joint wit
- Page 97 and 98:
JOINTS 6:403T-joint, 45° flexible,
- Page 99 and 100:
DyJOINTS 6:405Double sealedT-joint
- Page 101 and 102:
JOINTS 6:407Measure joint400-700Con
- Page 103 and 104:
Monitoring systems 7:1027.1 WiDetec
- Page 105 and 106:
Monitoring systems 7:104WiDetect On
- Page 107 and 108:
Monitoring systems 7:106Survey of s
- Page 109 and 110:
Monitoring systems 7:2017.2 Pipegua
- Page 111 and 112:
Monitoring systems 7:203cTubeTM Ala
- Page 113 and 114:
Monitoring systems 7:302Alarm Syste
- Page 115 and 116:
ACCESSORIES 8:101In wall sealsLEAD
- Page 117 and 118:
ACCESSORIES 8:202Shut-off valvesSER
- Page 119 and 120:
ACCESSORIES 8:302MiscellaneousHEAT
- Page 121 and 122:
ACCESSORIES 8:401Portion foamJoints
- Page 123 and 124:
Design guidelines 9:101A new pipe-S
- Page 125 and 126:
Design guidelines 9:103Assumptions
- Page 127 and 128:
Design guidelines 9:201Calculating
- Page 129 and 130:
Design guidelines 9:203Copper flexi
- Page 131 and 132:
Design guidelines 9:302Single pipe
- Page 133 and 134:
Design guidelines 9:401PlanningFoam
- Page 135 and 136:
Transportation and storage 10.1Thes
- Page 137 and 138:
Trench 10.2.110.2.1 DimensionsThe p
- Page 139 and 140:
Installation 10.3.210.3.14 Angles o
- Page 141 and 142:
Installation 10.3.4Ground anchoring
- Page 143 and 144:
Installation 10.3.6Expansion absorp
- Page 145 and 146:
EksaktometerInstallation 10.3.8Insu
- Page 147 and 148:
Installation Mittel 10.3.1010.3.31
- Page 149 and 150:
Installation 10.3.1210.3.34 Double
- Page 151 and 152:
Installation 10.3.14● Check the s
- Page 153 and 154:
Installation 10.3.1610.3.35 End cap
- Page 155 and 156:
Montage 10.3.1810.3.24 Plug Instruc
- Page 157 and 158:
Installation 10.3.2010.3.39 Table f
- Page 159 and 160:
INSTALLATION 10.3.22Foam liquids fo
- Page 161 and 162:
Installation 10.3.2410.3.43 Foam li
- Page 163 and 164:
Safety rules and directions 10.5.11
- Page 165 and 166:
Instructions for ball valve 10.6.11