11.07.2015 Views

Agilent capillary electrophoresis system

Agilent capillary electrophoresis system

Agilent capillary electrophoresis system

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

CE solutions – the alternative for ionsCapillary <strong>electrophoresis</strong> is a true alternative to ion chromatography.Its main features include:• unmatched analysis time—enhancing your sample throughput• high resolving power—allowing analysis of complex samples in one run• typically < 1 ml of solvent required with only a small amount of waste— savingmoney and helping to protect the environment• no need for specialized columns, precolumns and membranes—easy instrumentsetup and maintenance• often no laborious sample preparation needed—just sample dilution• only nanoliter amounts of samples injected—allowing different methodsor analytical techniques to be applied to one sampleAbsorbance [mAU]Ionic contamination in primary andsecondary circuit water leading to metalcorrosion, is a major problem for thenuclear power generating industry.For this reason low levels of smallanions and cations must be monitored.CE provides a rapid and facile methodfor their determination in the lowppb range.Bromide ChlorideSulfateOxalate Nitrate NitriteChlorateFluorideFormate3 4 5 6 7 8 9Time [min]ChecklistPhosphateþ Ease of sample preparationþ Low sample consumptionþ Fast separationþ Minimal maintenanceþ Low cost of ownershipþ Low ppb sensitivityAcetatePower plantsAbsorbance [mAU]2.521.510.50-0.5ChlorideSulfateNitriteNitrate2 2.5 3 3.5 4 4.5Time [min](Data kindly provided bt Thomas Ehmann,Wacker Siltronic AG, Burghausen, Germany)Semiconductor industry“Capillary <strong>electrophoresis</strong>, as a microanalytical technique,features merits in the determination of contaminants on wafersurfaces. As the diameter increases, the financial value of thewafers increases exponentially, therefore it is mandatory toapply a great variety of different analysis techniques whenworking on one single wafer. This is possible with CE dueto the low sample volume. Moreover, by changing only thecomposition of the electrolyte, a broad variety of analytesin different matrices can be determined.CE covers a range from ionic to non-ionic analytes that areimportant in the semiconductor industry.”OxalateCitrateDr. Laszlo Fabry(Wacker Siltronic AG, Germany)FluorideFormate

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!