11.07.2015 Views

PR430S2 WEIGHT INDICATOR

PR430S2 WEIGHT INDICATOR

PR430S2 WEIGHT INDICATOR

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>WEIGHT</strong> <strong>INDICATOR</strong>5.3.3 Function Codes SupportedFunction Code0x010x030x050x060x100x2B<strong>PR430S2</strong>DescriptionREAD COILSUsed to read the status of the 2 trip outputs.READ HOLDING REGISTERSUsed to read the gross & net weights, error codeand decimal places setting.WRITE SINGLE COILUsed to set the "Tare Net", "Zero Gross" or“Switch Display” bits to perform the appropriateaction. These flags are auto-cancelling after theaction has been performed.NOTE: If the zero gross cannot be performed,the error code will be set to 1814. The error codeholding register should therefore be read afterthe zero gross bit is set to determine if the actionwas successful.WRITE SINGLE REGISTERUsed to write a single holding register value. Thisfunction code is only appropriate for writing to theSense parameters as all other writable valuesspan multiple registers.WRITE MULTIPLE REGISTERSUsed to write multiple configuration values in onemessage.ENCAPSULATED INTERFACE TRANSPORTUsed with MEI Type 14 to read the deviceidentification object.5.3.4 Bits (coils)Coil Number Address Description1 0x00 Trip 1. This bit is read-only.2 0x01 Trip 2. This bit is read-only.3 0x02 Tare Net. This bit is write-only.4 0x03 Zero Gross. This bit is write-only.Issue 3.3 December, 2010 Page 29 of 40