11.07.2015 Views

Third Benchmarking Report on Quality of Electricity Supply

Third Benchmarking Report on Quality of Electricity Supply

Third Benchmarking Report on Quality of Electricity Supply

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

countries compared with 6 in the First <str<strong>on</strong>g>Report</str<strong>on</strong>g>. Comparis<strong>on</strong>s <strong>of</strong> performance are made forunplanned and planned outages, outages <strong>of</strong> short durati<strong>on</strong> and an attempt has been made toinvestigate unplanned performance excluding excepti<strong>on</strong>al events. As in the previous two reportsdata limitati<strong>on</strong>s have meant that detailed comparis<strong>on</strong>s could not be carried out for all countries.1.3 Main C<strong>on</strong>clusi<strong>on</strong>s <strong>on</strong> C<strong>on</strong>tinuity <strong>of</strong> <strong>Supply</strong> Regulati<strong>on</strong> – Drawn from the CEER’s<str<strong>on</strong>g>Third</str<strong>on</strong>g> <str<strong>on</strong>g>Benchmarking</str<strong>on</strong>g> <str<strong>on</strong>g>Report</str<strong>on</strong>g>A number <strong>of</strong> encouraging trends have been observed in carrying out work <strong>on</strong> the <str<strong>on</strong>g>Third</str<strong>on</strong>g> <str<strong>on</strong>g>Report</str<strong>on</strong>g>:· The durati<strong>on</strong> <strong>of</strong> unplanned interrupti<strong>on</strong>s shows (for most countries) a significant downwardtrend;· The number <strong>of</strong> unplanned interrupti<strong>on</strong>s shows (for most countries) a downward trend;· Excluding excepti<strong>on</strong>al events from unplanned performance figures highlights the significantimprovements being made by many European countries in terms <strong>of</strong> both the durati<strong>on</strong> andnumber <strong>of</strong> interrupti<strong>on</strong>s;· Countries with previously low levels for durati<strong>on</strong> and number <strong>of</strong> interrupti<strong>on</strong>s have been ableto make further improvements; and· Short interrupti<strong>on</strong>s have generally not been rising despite an increased move to automati<strong>on</strong>and remote c<strong>on</strong>trol techniques.1.4 C<strong>on</strong>tinuity <strong>of</strong> <strong>Supply</strong> Questi<strong>on</strong>naire1.4.1 C<strong>on</strong>tinuity Indicators UsedThe c<strong>on</strong>tinuity indicators which form the basis <strong>of</strong> the c<strong>on</strong>tinuity analysis in this report 5 are:· “System Average Interrupti<strong>on</strong> Durati<strong>on</strong> Index” (SAIDI), in some countries referred to as“Customer Minutes Lost per customer per year” (CMLs)· “System Average Interrupti<strong>on</strong> Frequency Index” (SAIFI), in some countries also referredas “Customer Interrupti<strong>on</strong>s per 100 customers per year” (CIs)· “Momentary Average Interrupti<strong>on</strong> Frequency Index” (MAIFI).· “Energy Not Supplied” (ENS)6· “Average Interrupti<strong>on</strong> Time” (AIT)7 .SAIDI measures the average durati<strong>on</strong> <strong>of</strong> outages for a power system. SAIFI and MAIFI measurethe average frequency <strong>of</strong> outages for the power system, respectively for l<strong>on</strong>g and for short interrupti<strong>on</strong>s.ENS is generally based <strong>on</strong> l<strong>on</strong>g interrupti<strong>on</strong>s, as the energy not supplied during short5For a comprehensive review <strong>of</strong> c<strong>on</strong>tinuity indicators, please see the document : IEEE Standard 1366-2003. IEEE Guide forElectric Power Distributi<strong>on</strong> Reliability Indices. IEEE, New York, NY, May 20046Norway uses ENS for all voltage levels greater than 1 kV.7For some countries such as Italy (until 2004), the informati<strong>on</strong> relating to AIT and ENS includes outages occurring at distributi<strong>on</strong>high voltage and may therefore result in higher values than those countries reporting solely outages <strong>on</strong> the transmissi<strong>on</strong> network.5<str<strong>on</strong>g>Third</str<strong>on</strong>g> <str<strong>on</strong>g>Benchmarking</str<strong>on</strong>g> <str<strong>on</strong>g>Report</str<strong>on</strong>g> <strong>on</strong> <strong>Quality</strong> <strong>of</strong> <strong>Electricity</strong> <strong>Supply</strong> – 2005 · Chapter 1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!