Configuring Scanning Values<br />

6-68<br />

Cisco <strong>IronPort</strong> AsyncOS 7.6 for Email Advanced Configuration Guide<br />

Chapter 6 Using Message Filters to Enforce Email Policies<br />

You can fine-tune image scanning by configuring the sensitivity setting, which helps reduce the number<br />

of false positives. For example, if you find that you are getting false positives, you can decrease the<br />

sensitivity setting. Or, conversely, if you find that the image scanning is missing inappropriate content,<br />

you may want to set the sensitivity higher. The sensitivity setting is a value between 0 (no sensitivity)<br />

and 100 (highly sensitive). The default sensitivity setting of 65 is recommended.<br />

To configure scanning values:<br />

Step 1 Go to Security Services > <strong>IronPort</strong> Image Analysis.<br />

Step 2 Click Edit Settings<br />

The Edit <strong>IronPort</strong> Image Analysis Settings page opens:<br />

Figure 6-4 Edit <strong>IronPort</strong> Image Analysis Settings<br />

Step 3 Configure the settings for image analysis sensitivity. The default sensitivity setting of 65 is<br />

recommended.<br />

Step 4 Configure the settings for Clean, Suspect, and Inappropriate verdicts.<br />

When you configure the value ranges, ensure that you do not overlap values and that you use whole<br />

integers.<br />

Step 5 Optionally, configure AsyncOS to bypass scanning images that do not meet a minimum size requirement<br />

(recommended). By default, this setting is configured for 100 pixels. Scanning images that are smaller<br />

than 100 pixels can sometimes result in false positives.<br />

You can also enable image analysis settings from the CLI via the imageanalysisconfig command:<br />

test.com> imageanalysisconfig<br />

<strong>IronPort</strong> Image Analysis: Enabled<br />

Image Analysis Sensitivity: 65<br />

Verdict Ranges: Clean (0-49), Suspect(50-74), Inappropriate (75+)<br />

OL-25137-01