12.07.2015 Views

Day and Night N4H Product.pdf

Day and Night N4H Product.pdf

Day and Night N4H Product.pdf

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

TECHNICAL SUPPORT MANUALSplit System Heat Pump: <strong>N4H</strong>3<strong>N4H</strong>360*KA Outdoor With FS(M,U)4X60**** Indoor Cooling<strong>N4H</strong>360AKA<strong>N4H</strong>360GKAOutdoor Ambient Temperature - ˚F, Dry Bulb75 85 95 105 115Entering Indoor Temperature - ˚F, Wet BulbCFM 72 67 63 †† 62 57 72 67 63 †† 62 57 72 67 63 †† 62 57 72 67 63 †† 62 57 72 67 63 †† 62 57MBh † 71.08 65.19 60.79 59.61 57.48 67.69 62.05 57.85 56.75 55.20 64.09 58.73 54.78 53.77 52.79 60.33 55.30 51.57 50.69 50.24 56.30 51.61 48.15 47.50 47.49S/T ‡ 0.51 0.69 0.72 0.90 1.00 0.51 0.70 0.73 0.92 1.00 0.52 0.72 0.75 0.95 1.00 0.53 0.74 0.76 0.97 1.00 0.54 0.76 0.79 1.00 1.001750AMPS^ 19.19 18.94 18.76 18.71 18.63 21.14 20.90 20.71 20.67 20.60 23.29 23.05 22.87 22.83 22.78 25.66 25.43 25.24 25.21 25.19 28.24 28.02 27.84 27.82 27.82HI PR 292 287 283 282 280 336 330 326 325 323 383 377 373 372 371 435 429 424 423 422 490 484 479 478 478LO PR 154 141 131 129 125 157 143 133 131 128 159 146 135 133 131 162 148 138 136 135 164 150 140 139 139MBh † 72.12 66.24 61.83 60.73 59.63 68.55 62.96 58.77 57.79 57.18 64.87 59.50 55.56 54.77 54.60 60.98 55.93 52.22 51.88 51.89 56.80 52.11 48.67 48.94 48.94S/T ‡ 0.52 0.72 0.75 0.95 1.00 0.53 0.74 0.76 0.97 1.00 0.54 0.75 0.78 0.99 1.00 0.55 0.78 0.80 1.00 1.00 0.56 0.80 0.83 1.00 1.002000AMPS^ 19.74 19.50 19.31 19.27 19.22 21.69 21.44 21.26 21.22 21.19 23.84 23.60 23.41 23.38 23.37 26.20 25.97 25.78 25.78 25.78 28.78 28.56 28.38 28.40 28.40HI PR 293 288 284 283 282 337 332 327 326 326 385 379 374 373 373 436 430 425 425 425 492 485 480 481 481LO PR 158 145 134 133 130 160 147 136 135 133 162 149 138 137 137 165 151 140 140 140 167 153 143 144 144MBh † 72.83 66.96 62.58 61.68 61.37 69.16 63.58 59.40 58.79 58.79 65.40 60.01 56.09 56.05 56.06 61.39 56.35 52.66 53.19 53.19 57.10 52.43 49.01 50.08 50.08S/T ‡ 0.54 0.75 0.78 0.99 1.00 0.54 0.77 0.79 1.00 1.00 0.56 0.79 0.81 1.00 1.00 0.57 0.81 0.84 1.00 1.00 0.58 0.84 0.87 1.00 1.002250AMPS^ 20.28 20.03 19.84 19.81 19.80 22.22 21.98 21.79 21.77 21.77 24.37 24.13 23.94 23.95 23.95 26.73 26.50 26.32 26.35 26.35 29.30 29.08 28.91 28.97 28.97HI PR 294 289 285 284 284 338 333 328 328 328 386 380 375 375 375 437 431 426 427 427 493 486 482 483 483LO PR 161 147 137 136 135 163 149 139 138 138 165 151 141 141 141 167 153 143 145 145 169 156 145 149 149† Total capacities are net (I.D. blower heat subtracted) system capacities based on 25’ line set.If additional tubing length <strong>and</strong>/or indoor unit is located above outdoor unit, a slight variation in capacity may occur.†† At TVA rating indoor condition (75 ˚F db, 63 ˚F wb), all other indoor air temperatures are at 80 ˚F dbIf additional tubing length <strong>and</strong>/or indoor unit is located above outdoor unit, a slight variation in capacity may occur.^ System amps are total of indoor <strong>and</strong> outdoor amps.‡ Chart data is for 80˚ F indoor dry bulb. For indoor db temperatures other than 80˚ F, measure Indoor db <strong>and</strong> Indoor CFM, <strong>and</strong> plug these into the formula below. Measure outdoor db <strong>and</strong> indoor wet bulb,apply these to the chart above, find MBh <strong>and</strong> S/T, <strong>and</strong> plug these into the formula below. (Note: if indoor db is the only thing changing, total capacity, MBh, stays the same.)Sensible Capacity at Indoor db LOWER than 80 ˚F = ( MBh x S/T ) -Sensible Capacity at Indoor db HIGHER than 80 ˚F = ( MBh x S/T ) +( )( )( 80 - Indoor db ) x 835 x Indoor CFM1000( Indoor db - 80 ) x 835 x Indoor CFM1000428 04 5100 00 11

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!