12.07.2015 Views

Day and Night N4H Product.pdf

Day and Night N4H Product.pdf

Day and Night N4H Product.pdf

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

TECHNICAL SUPPORT MANUALSplit System Heat Pump: <strong>N4H</strong>3<strong>N4H</strong>330*KA Outdoor With FS(M,U)4X30**** Indoor Cooling<strong>N4H</strong>330AKA<strong>N4H</strong>330GKAOutdoor Ambient Temperature - ˚F, Dry Bulb75 85 95 105 115Entering Indoor Temperature - ˚F, Wet BulbCFM 72 67 63 †† 62 57 72 67 63 †† 62 57 72 67 63 †† 62 57 72 67 63 †† 62 57 72 67 63 †† 62 57MBh † 34.73 31.78 29.62 29.07 27.79 33.11 30.31 28.24 27.72 26.72 31.41 28.75 26.78 26.29 25.58 29.62 27.09 25.22 24.80 24.36 27.66 25.29 23.55 23.20 23.03S/T ‡ 0.51 0.68 0.71 0.89 1.00 0.51 0.69 0.72 0.90 1.00 0.52 0.71 0.74 0.93 1.00 0.53 0.72 0.75 0.95 1.00 0.54 0.75 0.77 0.98 1.00875AMPS^ 9.70 9.67 9.66 9.65 9.64 10.85 10.82 10.81 10.80 10.79 12.12 12.09 12.07 12.06 12.06 13.51 13.48 13.46 13.45 13.45 15.02 14.99 14.97 14.96 14.96HI PR 287 283 280 279 277 330 325 322 321 319 376 372 368 367 366 427 422 419 418 417 482 477 473 473 472LO PR 149 136 127 124 119 151 138 129 127 122 154 141 131 129 126 156 143 133 132 130 159 146 136 135 134MBh † 35.33 32.36 30.19 29.66 28.86 33.65 30.83 28.75 28.27 27.72 31.88 29.20 27.22 26.81 26.50 30.02 27.47 25.60 25.31 25.21 27.99 25.61 23.86 23.78 23.79S/T ‡ 0.52 0.71 0.73 0.92 1.00 0.52 0.72 0.75 0.95 1.00 0.53 0.74 0.77 0.97 1.00 0.54 0.76 0.79 0.99 1.00 0.56 0.78 0.81 1.00 1.001000AMPS^ 9.90 9.87 9.85 9.85 9.84 11.05 11.02 11.00 11.00 10.99 12.32 12.29 12.27 12.26 12.26 13.71 13.68 13.66 13.65 13.65 15.21 15.19 15.17 15.16 15.17HI PR 288 284 281 280 279 331 326 323 322 321 378 373 369 368 368 429 423 420 419 419 483 478 474 474 474LO PR 152 139 130 128 124 154 141 132 130 127 157 144 134 132 131 159 146 136 135 135 162 149 139 139 139MBh † 35.80 32.81 30.63 30.16 29.74 34.05 31.22 29.13 28.75 28.54 32.23 29.53 27.56 27.28 27.26 30.31 27.75 25.89 25.89 25.89 28.22 25.84 24.10 24.40 24.40S/T ‡ 0.53 0.74 0.76 0.96 1.00 0.54 0.75 0.78 0.98 1.00 0.55 0.77 0.80 1.00 1.00 0.56 0.79 0.82 1.00 1.00 0.57 0.82 0.85 1.00 1.001125AMPS^ 10.10 10.07 10.05 10.05 10.04 11.25 11.22 11.20 11.20 11.19 12.51 12.49 12.47 12.46 12.46 13.90 13.87 13.86 13.85 13.86 15.41 15.39 15.36 15.37 15.37HI PR 289 285 281 281 280 332 327 324 323 323 379 374 370 370 370 429 424 420 421 421 484 479 475 476 476LO PR 155 142 132 131 129 157 144 134 133 132 159 146 136 135 135 162 149 138 139 139 165 151 141 143 143† Total capacities are net (I.D. blower heat subtracted) system capacities based on 25’ line set.If additional tubing length <strong>and</strong>/or indoor unit is located above outdoor unit, a slight variation in capacity may occur.†† At TVA rating indoor condition (75 ˚F db, 63 ˚F wb), all other indoor air temperatures are at 80 ˚F dbIf additional tubing length <strong>and</strong>/or indoor unit is located above outdoor unit, a slight variation in capacity may occur.^ System amps are total of indoor <strong>and</strong> outdoor amps.‡ Chart data is for 80˚ F indoor dry bulb. For indoor db temperatures other than 80˚ F, measure Indoor db <strong>and</strong> Indoor CFM, <strong>and</strong> plug these into the formula below. Measure outdoor db <strong>and</strong> indoor wet bulb,apply these to the chart above, find MBh <strong>and</strong> S/T, <strong>and</strong> plug these into the formula below. (Note: if indoor db is the only thing changing, total capacity, MBh, stays the same.)Sensible Capacity at Indoor db LOWER than 80 ˚F = ( MBh x S/T ) -Sensible Capacity at Indoor db HIGHER than 80 ˚F = ( MBh x S/T ) +( )( )( 80 - Indoor db ) x 835 x Indoor CFM1000( Indoor db - 80 ) x 835 x Indoor CFM1000428 04 5100 00 7

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!