12.07.2015 Views

Day and Night N4H Product.pdf

Day and Night N4H Product.pdf

Day and Night N4H Product.pdf

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

TECHNICAL SUPPORT MANUALSplit System Heat Pump: <strong>N4H</strong>3<strong>N4H</strong>360*KA Outdoor With FS(M,U)4X60**** Indoor Heating<strong>N4H</strong>360AKA<strong>N4H</strong>360GKAOutdoor Ambient Temperature - ˚F, Dry Bulb- 3 7 17 27 37 47 57 67Entering Indoor Temperature - ˚F, Wet BulbCFM 65 70 75 65 70 75 65 70 75 65 70 75 65 70 75 65 70 75 65 70 75 65 70 75MBh † 25.07 24.34 23.57 30.90 30.22 29.50 37.17 36.54 35.86 43.81 43.21 42.56 51.11 50.41 49.72 59.85 58.98 57.81 68.95 68.13 67.28 78.00 77.06 76.15T/R 14.10 13.90 13.50 17.50 17.30 17.00 21.20 21.10 20.90 25.20 25.10 24.90 29.70 29.50 29.40 35.10 34.90 34.40 40.80 40.70 40.50 46.70 46.50 46.301750AMPS^ 16.76 17.53 18.33 17.39 18.21 19.05 18.10 18.96 19.87 18.87 19.79 20.74 19.75 20.71 21.71 20.83 21.88 22.89 21.82 22.87 23.95 23.10 24.18 25.31HI PR 230 246 263 243 260 278 257 275 294 275 294 313 295 315 335 318 339 360 342 363 385 371 393 416LO PR 34 34 34 44 44 44 55 55 56 68 68 68 82 82 83 98 98 99 115 115 116 131 132 133MBh † 25.62 24.89 24.12 31.49 30.80 30.09 37.79 37.17 36.50 44.47 43.87 43.24 51.96 51.17 50.48 60.88 60.00 58.94 69.47 68.71 67.93 78.33 77.50 76.69T/R 12.60 12.40 12.10 15.60 15.40 15.20 18.80 18.70 18.50 22.30 22.20 22.00 26.20 26.00 25.90 31.00 30.80 30.50 35.70 35.60 35.50 40.60 40.50 40.402000AMPS^ 17.07 17.84 18.64 17.64 18.45 19.29 18.26 19.12 20.02 18.94 19.85 20.79 19.74 20.67 21.66 20.59 21.60 22.67 21.51 22.54 23.60 22.61 23.67 24.78HI PR 226 242 259 237 255 272 250 268 286 266 285 304 284 303 323 303 324 345 325 346 368 350 372 395LO PR 33 34 34 43 44 44 55 55 55 67 68 68 82 82 82 98 98 98 113 114 115 129 130 131MBh † 26.13 25.40 24.63 32.03 31.34 30.63 38.34 37.72 37.07 45.07 44.46 43.83 52.72 51.85 51.15 61.49 60.72 59.80 69.75 69.06 68.35 77.76 77.77 76.95T/R 11.40 11.20 10.90 14.10 13.90 13.70 16.90 16.80 16.60 20.00 19.90 19.80 23.50 23.40 23.20 27.70 27.60 27.40 31.60 31.60 31.50 35.50 35.80 35.702250AMPS^ 17.42 18.20 18.99 17.94 18.74 19.59 18.50 19.36 20.25 19.12 20.01 20.95 19.86 20.76 21.73 20.56 21.54 22.57 21.41 22.41 23.46 22.29 23.43 24.51HI PR 223 239 256 233 250 268 245 262 281 259 278 297 276 295 315 293 312 333 312 333 354 333 357 379LO PR 33 34 34 43 44 44 55 55 55 67 68 68 82 82 82 97 98 98 112 113 114 126 128 129† Total capacities are net (I.D. blower heat subtracted) system capacities based on 25’ line set.If additional tubing length <strong>and</strong>/or indoor unit is located above outdoor unit, a slight variation in capacity may occur.^ System amps are total of indoor <strong>and</strong> outdoor amps.18 428 04 5100 00

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!