Impact<strong>Force</strong>Impact<strong>Force</strong> takes its name from the tough polycarbonate diffuser,able to withstand high impacts of up to IK09. Impact<strong>Force</strong> is suitablefor locations where impact to the luminaire may occur or vandalresistance is required. Typical applications are loading bays, multistorey car parks, subways, sports stadiums and warehouses.Corrosion<strong>Force</strong>As the name suggests Corrosion<strong>Force</strong> is the answer when you need tolight an area where the atmosphere contains trace chemicals that maycontaminate a standard IP65 luminaire. Typical applications includefood processing and preparation areas where specialist-cleaningagents are used.Cold<strong>Force</strong><strong>Lighting</strong> a cold store or chill room is challenging, the low temperatureswould impair most <strong>luminaires</strong>. Cold<strong>Force</strong> with its high specificationindustrial ballast and thermal over tubes ensures good lightperformance down to temperatures of -30°C. Typical applicationsinclude cold stores and chill rooms.Heat<strong>Force</strong>High ambient temperatures have a lasting effect on the reliability ofmost <strong>luminaires</strong>. Heat<strong>Force</strong> is designed to operate in temperatures upto 65°C. The tough construction and special control gear providesreliable lighting even when things start to heat up. Typical applicationsare boiler rooms and any areas where machinery or other equipmentgenerate high ambient temperatures.Storm<strong>Force</strong>Storm<strong>Force</strong> is a rugged luminaire with inner strength. Internal steelsupports for strength, fixing brackets for mounting onto stanchions orflexible structures that are exposed to high winds and rain. Ideal forpower stations and exposed coastal areas.3


Performance, Efficiency and Comfort (PEC) –for a better lit environmentX-<strong>Force</strong> evokes the spirit of <strong>Thorn</strong> <strong>Lighting</strong>’sdynamic, results-orientated PEC programmeThe PEC programme is based onthe principle that Performance,Efficiency and Comfort determinethe effectiveness of lighting, itsimpact on the people using it,and its impact on the naturalenvironment. X-<strong>Force</strong> delivers theright light on the right place at theright time.Performance: Providing thebest visual effectiveness• The X-<strong>Force</strong> range has anoptical system optimised forfluorescent lamps. The highreflectance back plate andspecially designed prismaticcontroller give a wide lightdistribution with good glarecontrol, uniformity andmodelling. The optic gives highlight output ratios, up to 93%.• Fluorescent light sourcesensure very good colourrendition (Ra over 80)Efficiency: Conserving energyand effort, reducing CO 2 emissionsand waste, providing lighting thatis practical and efficient to install,operate and maintain• X-<strong>Force</strong> uses the latesttechnologies to set the pace inenvironmental sensitivity. Withthe latest lamp technology, suchas T16 high output and highefficiency lamps. Digitaldimmable versions are alsoavailable• X-<strong>Force</strong> is fit for purpose.Within the range there is achoice of diffuser materialsdepending on the industrialapplication the luminaire isoperating within. The cleverdesign of the deep channelgasket ensures the long life ofthe IP65 sealComfort: giving peoplesatisfaction and stimulation• A HF electronic ballast offersthe option to remove anyflicker effect associated withfluorescent lighting and helps toremove any discomfort in theworkplace• Material choice and emergencyversions ensure a feeling of safety• Effective glare free light• With a focus on easy installationand maintenance the rangecomes with Quick-fix brackets asstandard and easy to usestainless steel gear tray clips5


X-<strong>Force</strong> application areasCold<strong>Force</strong>Cold StoreHeat<strong>Force</strong>Boiler RoomImpact<strong>Force</strong>WarehouseStorm<strong>Force</strong>Emergency Exit6


KitchenCorrosion<strong>Force</strong>Food PreparationImpact<strong>Force</strong> is a vandal resistant luminaire that can withstand accidental damage.Typical applications are loading bays, multi storey car parks, subways, sports stadiumsand warehouses.• High impact polycarbonate diffuser• T16 and T26 options• Dimmable and emergency optionsCorrosion<strong>Force</strong> is suitable for any location where the atmosphere contains tracechemicals or where specialist cleaning agents are used. Typical applications includekitchens, food processing areas, dairies and agricultural buildings.• PMMA diffuser• T16 and T26 options• Dimmable and emergency optionsCold<strong>Force</strong> provides an IP65 lighting solution in low temperature locations. Typicalapplications are cold stores and chill rooms.• High impact polycarbonate diffuser• -30°C low temperature operation• Long life industrial ballastHeat<strong>Force</strong> is a lighting solution for any location that generates high ambient temperatures.Typical applications are boiler rooms or industrial locations.• High impact polycarbonate diffuser• 65°C high temperature operation• Long life industrial ballastStorm<strong>Force</strong> can be used on walkways, metal gantries and flexible structures. Ideal forpower stations and exposed coastal areas.• Polycarbonate or PMMA diffuser options• T16 and T26 options• Emergency options7


X-<strong>Force</strong> - designed to meet the toughest of applicationsIn situations where conventional <strong>luminaires</strong> are readyto give up, the new X-<strong>Force</strong> range really comes intoits own. Whether confronted with dirt, dust, moistureor chemical atmospheres, within the X-<strong>Force</strong> rangethere is a product that gives durable functionality andappropriate lighting quality in difficult environments.Stainless Steel tamperproof togglesThe stainless steel togglesare supplied as standard.The toggle easily fits intothe canopy, once fitted itis secure.The diffuser is clamped intoposition with a simple clickof the toggles. To removethe diffuser a screwdriveris required deterring anyunwanted interference ortampering with the luminaire.Quick-fix bracketsThe X-<strong>Force</strong> range is suppliedwith Quick-fix brackets asstandard. The bracket fitsonto the ceiling and then thecanopy can be snapped intoplace.Using the Quick-fix bracketavoids the need to perforatethe top of the canopy andensures the luminairemaintains its IP65 rating.Easy to cleanThe X-<strong>Force</strong> range meetsthe recommendations ofthe International FoodStandards (IFS) and BritishRetail Consortium (BRC).The sleek design has a15° slope which makes itdifficult for dust or moistureto accumulate, so it easy toclean and keep clean.Stainless steel gear clipsWithin the canopy ofX-<strong>Force</strong> sit the stainless steelgear tray retaining clips.Cleverly designed toallow the gear tray to beeasily clipped and lockedinto position.When essential maintenanceis required the gear tray canbe released and will hangfrom the clips.8


X-<strong>Force</strong> - its constructionThe key materials employedin the manufacture of X-<strong>Force</strong><strong>luminaires</strong> are:• Glass Reinforced Plastic (GRP)The main advantages of GRP are chemical resistance and strength.It has a high strength to weight ratio and flexural strength. It is idealwhere luminaire bodies are exposed to harsh environments as itprovides resistance to UV light, extreme temperatures, salt air, and avariety of chemicals.• Polycarbonate (PC)Transparency, excellent toughness and a good dimensional stabilitymake polycarbonate (PC) one of the most widely used thermoplasticsfor lighting diffusers. Constraints include fair resistance to UV radiation.• Polymethylmethacrylate (PMMA)Better known as acrylic this material is used for diffusers because of itshigh light transmittance and good UV resistance. Its limitations are lowimpact strength and poor flame resistance.Comparison table PMMA PC GRPUV Resistance Good Fair GoodImpact Resistance 0.2Nm 10Nm 0.35NmResistance to ageing Excellent Good ExcellentSilicone free Yes Yes YesHalogen free Yes Yes YesGlow wire test 650°C 850°C 850°CHeat resistance of plastics 95° 125° 160°UV Transmittance 91% 89% N/A9


X-<strong>Force</strong> for emergencyEuropean safety standards specify that emergencylighting is required in all public places to enablea safe exit if the normal lighting fails. Emergencylighting has to provide suffi cient lighting to aidsafe evacuation.<strong>Thorn</strong>’s X-<strong>Force</strong> range of <strong>luminaires</strong> offers a number of emergencylighting options that are integrated into the waterproof luminaireensuring a totally compliant lighting scheme. This approach improvesthe appearance of the location while reducing installation cost andcomplexity.The options support integrated emergency operation for three hours,allowing full continuity of emergency lighting after an evacuation. Tomeet legal requirements for the inspection, test and maintenance ofemergency lighting, Self Test emergency lighting options include adiagnostic microprocessor that will automatically perform functionaltests and duration tests.Quick and easy to install without additional cabling, it monitorsand automatically tests emergency <strong>luminaires</strong> at specified intervals,displaying the status of each unit using a two-colour LED. As a result,any problems with battery and lamp health are detected early, withoutrequiring manual inspection.Key Features in emergency lighting• Compliant with EN60598 2.22.• Faster than average rechargetime of 10-15 hours allowsearlier reinstatement ofemergency system after fullbattery discharge• Three hours operation providescontinuity of emergencysystems after testing orevacuation• Two-colour LED provides clearstatus indication (red for faults,green for healthy)• Boost starting gives higherlumen output during the criticalswitchover phase, ensuringgreater visibility of potentialdanger• Automatic commissioningwithout programming savestime and money• <strong>Thorn</strong> Explorer Project orVision versions, where the usercan monitor the emergencyluminaire status centrally, andrecord the status as requiredby the legislative norm, areavailable on request10


X-<strong>Force</strong> for dimming andenergy savingThe X-<strong>Force</strong> range offers energy savingwith the option of dimmable <strong>luminaires</strong>or Switchlight detectorsIn combination with Sensa,<strong>Thorn</strong>’s Indoor <strong>Lighting</strong> Controlrange, X-<strong>Force</strong> installations willprovide light at the right time,the right place and with the rightlight level, to increase efficiencyand comfort.SensaLite is a range of standaloneproducts that are ideal forthe use with the X-<strong>Force</strong> range.• SwitchLite detectors will linktogether fixed output versionsof X-<strong>Force</strong> (HF) providing lightonly when it is needed. Forindoor or outdoor applicationswhere a high IP rating isrequired the SWITCHLITEMWA SLD IP64 (available inwhite 96233650, or black96233649) is the right choice.In corridor or warehouseapplications there are anumber of options including thewall mounted SWITCHLITE SLDLONG RANGE (96012710)with a 12m detection rangeand the recessed wallmounted SWITCHLITE SLDM(96019208) with a 30mdetection range, an idealsolution for saving energywhen the location is notbeing used.• The ROTARYDIM RDMR(96218669) enables users tomanually control the dimmableversions of X-<strong>Force</strong> (HFD). Thisproduct is used like a standarddomestic rotary dimmer,but provides the benefits ofdigital dimming. For examplein smaller production areas(indoors) where a manualchange of light levels isrequested.• Installing SensaDigital allowsthe HFD versions of X-<strong>Force</strong>to be daylight and presencelinked. The surface mountedmultisensor head SENSAMSF SEND DSI (96013491)controls a group of X-<strong>Force</strong><strong>luminaires</strong> incorporating up to8 DSI ballasts in total. Usingthe infra-red programming toolSENSA SENP (96004189)the multisensor’s parameterscan be easily configured, e.g.SensaDigital will maintain thesame light levels over the day.SensaDigital is typically usedin zoned areas and with ceilingheights around 3m. Typicalapplications are daylightlitcorridors, staircases andproduction areas.If you require more informationon energy saving or if you wishto learn more about the SensaIndoor <strong>Lighting</strong> Controls portfolio,please contact your <strong>Thorn</strong>representative, or visit our website:www.thornlighting.comPresence-link indoors and outdoors withSWITCHLITE MWA SLD IP64Presence-link indoors withSWITCHLITE SLD LONG RANGE IP64Manual dimming and brightening withROTARYDIM RDMRPresence-link and maintained illuminancelevel with SENSA MSF SEND DSIHFDHFDHFDHFDSensor connected to luminaire group(max. 8 ballasts in total)11


Mechanical testsTests subject components to torques and forces that may occur inpractice. A spring-operated impact hammer is used to test themechanical strength of components and a vibration rig to replicateexterior windage.IP testsFor an IP65 classification (dust-tight and jetproof) <strong>luminaires</strong> must resistingress of dust with a particle size down to 1 micron and resist ingressof water from a hose or jet pressure of 30KN/m². Luminaires areswitched on during testing and allowed to reach their normal operatingtemperature as it needs to be established whether the water or dust isdrawn in when the pressure drops.Electrical testsA safety requirement is that no live parts should be accidentallytouched. This is checked by using a standard test finger. Also<strong>luminaires</strong> must satisfy requirements such as minimum creepagedistances across the surface of insulating materials, and minimumclearance distances between live parts and earth or touchable metalparts. Luminaires must pass high-voltage flash tests and insulationresistance tests in humid conditions.Thermal testsA standard draught-free room is usually used for luminaire temperaturemeasurement. The components inside the luminaire are fitted with manythermocouples and it is operated under specific conditions until thetemperatures indicated by these thermocouples are stable.Environmental testsLuminaires are subjected to long-term environmental testing andinstalled outdoors so the effect of weathering can be seen. UVdegradation tests (discharge rig) and salt spray test chambers areemployed for accelerated corrosion testing. The latter consists of acontrolled temperature environment in which corrosive mist, usuallybased on sodium chloride, is produced. Likewise chemical and stresscrazing tests are conducted with samples being immersed orsuspended above various chemicals.13


X-<strong>Force</strong> - easy to install1. 2. 3. 4.5. 6. 7.8.1. Unpack the luminaire, open andremove the bag of installationaccessories from the canopy.2. Fit the toggles to canopy. Oncefitted the toggles are designed sothey do not come adrift from thecanopy and it's almost impossibleto lose them, a great advantageduring installation or maintenance.3. Fit the Quick-fix brackets ontothe ceiling.4. Snap the canopy into the Quick-fixbrackets, it will easily click into place.5. Prepare the luminaire for theelectrical connection, for easyinstallation hinge the gear tray onthe gear tray clips, insert cablesthrough the sealing grommet andattach to the plug-in terminal block.6. Align the gear tray with thestainless steel gear clips.7. Snap the gear tray into place.8. Align the diffuser into the canopyand complete the insulation bysnapping the toggles into place,which will hold the diffuser.9. Test the luminaire.✔✔Luminaire mounting positions✔✔✗✗14


Chemical resistance tableWhen selecting an X-<strong>Force</strong> for an application you will need to consider how external chemical substances may affect the luminaire. This may be a corrosive element in the atmosphere oreven cleaning agents used in the location. No materials can withstand the effects of every chemical and it would be difficult to display the entire list. But the table below is a selection of themost common chemicals that are used in applications the X-<strong>Force</strong> would come into contact with. The information contained in the table is valid under the following conditions:• The chemical substance listed in the table is an element and not part of a chemical compound• The ambient temperature is 22°CChemical Type Chemicals Specific Impact<strong>Force</strong> Corrosion<strong>Force</strong> Cold<strong>Force</strong> Heat<strong>Force</strong> Storm<strong>Force</strong> Storm<strong>Force</strong>GRP body GRP body GRP body GRP body GRP body GRP bodyPC diffuser PMMA diffuser PC diffuser PC diffuser PC diffuser PMMA diffuserStainless toggle Stainless toggle Stainless toggle Stainless toggle Stainless toggle Stainless toggleAcids acetic


Impact<strong>Force</strong>A high performanceimpact resistant, IP65proof fluorescent rangeImpact<strong>Force</strong> is a rugged tough luminaire suitable for a wide range ofapplications that are indoors or in semi outdoor areas. In industriallocations there are dangers from moving vehicles or machinery, whichcan cause accidental impact damage to the luminaire. The diffuser hasbeen designed to withstand impacts of up to IK09 and continue tooperate. Other suitable locations are car parks and pedestriansubways, where the tough construction and vandal resistant togglesdeter any unwanted interference.Impact<strong>Force</strong> has a wide range of variants including T16 and T26 lampoptions plus emergency and dimmable options.Lamps18-70W T26 (FD) linearfluorescent. Cap: G1328-80W T16 (FDH) linearfluorescent, Cap: G5Materials/FinishCanopy: glass-fibrereinforced polyester.Diffuser: polycarbonate withlinear prisms.Gasket: expanded polyurethaneToggles: stainless steelGear tray: steel, whiteenamelled finishInstallation/MountingCable entry positions at theback and each end of the fitting.Supplied with IP65 grommetStainless steel quick fix bracketssupplied with each luminaire,Stainless steel toggles are captivein the canopy to prevent lossduring maintenance, and steelgear tray is retained by fingeroperated spring latches.Accessory kits for BESA boxmounting, conduit mounting,chain suspension and catenarysuspension are all available.Through wire kits can be specifiedfor use with non-emergencyversions (see accessories listing).StandardsDesigned and manufactured tocomply with EN 60598Emergency EN60598 2.22.Class I ElectricalIK09 (diffuser)IK03 (canopy)850°C fire retardant(glow wire test)IP65SpecificationTo specify state:High performance, IP65, dustand moisture proof impactresistant luminaire with GRPcanopy, polycarbonatediffuser and stainless steeltoggles, 18-70W T26 linearfluorescent lamps or 28-80WT16 linear fluorescent lamps,digital dimming and emergencyoptions, with HF gear ormagnetic gear.As <strong>Thorn</strong> Impact<strong>Force</strong>.Key Features• GRP canopy• High impact polycarbonatediffuser• Choice of T26 or T16 lamps• Switchstart or High Frequencycontrol gear• Integral 3 hour maintainedemergency versions• Digital Dim options• Horizontal or verticalapplications• Vandal resistant• Stainless steel toggles• Through wire options• Quick-fix brackets supplied• LSOH cable as standardImpact<strong>Force</strong> Diffuser PC Canopy GRPUV Resistance Fair GoodImpact Resistance 10Nm 0.35NmResistance to ageing Good ExcellentSilicone free Yes YesHalogen free:LuminaireInternal WiringFood gradecertification(15° angle)YesYesYesApplications• Industrial warehouses• Subways• Storage sites• Lavatories• Changing rooms• Garages• Underground carparks• Railway platforms• Loading bays• Factories• Sport stadiums• Work areas• Multi storey carparks• StadiaYesn/aYesGlow wire test 850°C 850°CHeat resistance of125°C 160°Cluminaire plasticsUV Transmittance 89% n/a18


Corrosion<strong>Force</strong>A high performance, corrosionresistant IP65 proof range. Madefrom materials selected to withstandaggressive atmospheres laden withsalts, acids and mineral oils.Corrosion<strong>Force</strong> is constructed from materials that make it suitablefor locations that are exposed to liquids or atmospheres that containpotentially corrosive chemicals. Typical areas include foodprocessing areas or milk dairies but also in areas where specialisedcleaning agents are used.When selecting Corrosion<strong>Force</strong> for an application care needs to betaken that it is suitable. Please check page 15 of this brochure forguidance or contact your local <strong>Thorn</strong> office of there is any doubt aboutthe suitability of a luminaire.Lamps18-70W T26 (FD) linearfluorescent. Cap: G1328-80W T16 (FDH) linearfluorescent, Cap: G5Materials/FinishCanopy: glass-fibrereinforced polyester.Diffuser: PMMA with linearprisms. Gasket: expandedpolyurethane.Toggles: stainless steel.Gear tray: steel, whiteenamelled finishInstallation/MountingCable entry positions at theback and each end of the fitting.Supplied with IP65 grommet,Stainless steel quick fix bracketssupplied with each luminaire,Stainless steel toggles arecaptive in the canopy to preventloss during maintenance, andsteel gear tray is retained byfinger operated spring latches.Accessory kits for BESA boxmounting, conduit mounting,chain suspension and catenarysuspension are all available.Through wire kits can be specifiedfor use with non-emergencyversions (see accessories listing).StandardsDesigned and manufactured tocomply with EN 60598Emergency EN60598 2.22.Class I ElectricalIK02 (diffuser)IK03 (canopy)650°C fire retardant(glow wire test)IP65SpecificationTo specify state:High performance, IP65, dustand moisture proof corrosionresistant luminaire with GRPcanopy, PMMA diffuser andstainless steel toggles, 18-70WT26 linear fluorescent lamps or28-80W T16 linear fluorescentlamps, digital dimming andemergency options, with HFgear or magnetic gear.As <strong>Thorn</strong> Corrosion<strong>Force</strong>.Key Features• GRP canopy• Corrosion resistant PMMAdiffuser• Choice of T26 or T16 lamps• Switchstart or High Frequencycontrol gear• Integral 3 hour maintainedemergency versions• Digital Dim options• Good chemical resistance• Horizontal or verticalapplications• Stainless steel toggles• Through wire options• Quick-fix brackets supplied• LSOH cable as standardCorrosion<strong>Force</strong> Diffuser PMMA Canopy GRPUV Resistance Good GoodImpact Resistance 0.2Nm 0.35NmResistance to ageing Excellent ExcellentSilicone free Yes YesHalogen free:LuminaireInternal WiringFood gradecertification(15° angle)YesYesYesApplications• Abattoirs• Agricultural buildings• Factories• Garages• Kitchens• Plant rooms• Process areas• Transport terminals• Wine Cellars• Paper processing• Textile processing plants• Cheese dairiesYesn/aYesGlow wire test 650°C 850°CHeat resistance of95°C 160°Cluminaire plasticsUV Transmittance 91% n/a20


Cold<strong>Force</strong>A high protection IP65 prooffl uorescent range for use in lowtemperature environmentsCold<strong>Force</strong> has been developed for use in low temperature applications.There are problems associated with standard fluorescent lamps whenlighting low temperature locations such as chill rooms and cold stores;the low temperatures have an effect the starting circuit and light output.Cold<strong>Force</strong> overcomes these problems by incorporating an industrialballast. This allows Cold<strong>Force</strong> luminaries to operate at temperaturesas low as -30°C, perfect for cold food storage areas. To minimisemaintenance costs Cold<strong>Force</strong> allows the user to install standard lampswhich are fitted into the supplied over tubes.Lamps36-58W T26 (FD) linearfluorescent. Cap: G13Materials/FinishCanopy: glass-fibrereinforced polyester.Diffuser: polycarbonatewith linear prisms.Gasket: expanded polyurethane.Toggles: stainless steel.Gear tray: steel, whiteenamelled finishInstallation/MountingCable entry positions at theback and each end of the fitting.Supplied with IP65 grommetStainless steel quick fix bracketssupplied with each luminaire,Stainless steel toggles are captivein the canopy to prevent lossduring maintenance, and steelgear tray is retained by fingeroperated spring latches. BESAbox and conduit mounting,chain suspension and catenarysuspension kits, plus throughwire kits are all available (seeaccessories listing)StandardsDesigned and manufacturedto comply with EN 60598Class I ElectricalIK09 (diffuser)IK03 (canopy)850°C fire retardant(glow wire test)IP65SpecificationTo specify state:High performance, IP65, dustand moisture proof impactresistant luminaire with GRPcanopy, polycarbonatediffuser and stainless steeltoggles, 36-58W T26 linearfluorescent lamps, industrialballast for reliable operationdown to -30°C, thermal overtubes fitted to standard tubesfor low maintenance.As <strong>Thorn</strong> Cold<strong>Force</strong>.Key Features• GRP canopy• High impact polycarbonatediffuser• Low temperature IndustrialBallast• Low temperature over tubes• Horizontal or verticalapplications• Stainless steel toggles• Does not require specialfluorescent lamps• Low maintenance costs• Quick-fix brackets supplied• LSOH cable as standardApplications• Chill rooms• Process areas• Wine Cellars• Cheese dairies• Cold storesCold<strong>Force</strong> Diffuser PC Canopy GRPUV Resistance Fair GoodImpact Resistance 10Nm 0.35NmResistance to ageing Good ExcellentSilicone free Yes YesHalogen free:LuminaireInternal WiringFood gradecertification(15° angle)YesYesYesYesn/aYesGlow wire test 850°C 850°CHeat resistance of125°C 160°Cluminaire plasticsUV Transmittance 89% n/a22


Heat<strong>Force</strong>High performance IP65 proofluminaire that will continue toperform in high ambienttemperature locationsHeat<strong>Force</strong> is suitable for tough industrial applications where ambienttemperatures can rise up to 65°C. Extreme temperatures have a lastingeffect on the reliability of standard proof <strong>luminaires</strong>. Heat<strong>Force</strong> hasbeen designed to operate safely in such demanding conditions, fittedwith a high performance industrial ballast that will give over 50,000hours operation.Lamps36-58W T26 (FD) linearfluorescent. Cap: G13Materials/FinishCanopy: glass-fibrereinforced polyester.Diffuser: polycarbonate withlinear prisms.Gasket: expanded polyurethane.Toggles: stainless steel.Gear tray: steel, whiteenamelled finishInstallation/MountingCable entry positions at theback and each end of the fitting.Supplied with IP65 grommetStainless steel quick fix bracketssupplied with each luminaire,Stainless steel toggles are captivein the canopy to prevent lossduring maintenance, and steelgear tray is retained by fingeroperated spring latches. BESAbox and conduit mounting,chain suspension and catenarysuspension kits, plus throughwire kits are all available (seeaccessories listing)StandardsDesigned and manufacturedto comply with EN 60598Class I ElectricalIK09 (diffuser)IK03 (canopy)850°C fire retardant(glow wire test)IP65SpecificationTo specify state:High performance, IP65, dustand moisture proof impactresistant luminaire with GRPcanopy, polycarbonatediffuser and stainless steeltoggles, 36-58W T26 linearfluorescent lamps, industrialballast for reliable operationup to 65°C, 50,000 hours atmaximum temperature.As <strong>Thorn</strong> Heat<strong>Force</strong>.Key Features• GRP canopy• High impact polycarbonatediffuser• High temperature industrialballast• Operation up to 65°• Horizontal or verticalapplications• IP65-Dust and moisture proof• Stainless steel toggles• Quick-fix brackets supplied• 65°C maximum temperaturefor 36W. 55°C maximumtemperature for 58W.• LSOH cable as standardApplications• Boiler rooms• Utility rooms• Machinery rooms• Heavy plant roomsHeat<strong>Force</strong> Diffuser PC Canopy GRPUV Resistance Fair GoodImpact Resistance 10Nm 0.35NmResistance to ageing Good ExcellentSilicone free Yes YesHalogen free:LuminaireInternal WiringFood gradecertification(15° angle)YesYesYesYesn/aYesGlow wire test 850°C 850°CHeat resistance of125°C 160°Cluminaire plasticsUV Transmittance 89% n/a24


Storm<strong>Force</strong>A specialist range of IP65 proof<strong>luminaires</strong> suitable for exteriorenvironments that are subjectto rain and strong windsStorm<strong>Force</strong> has been developed for applications that require IP65proof <strong>luminaires</strong> to perform in environments exposed to rain andstrong winds. Luminaires mounted on poles, metal gantries or flexiblestructures that may distort under high winds causing the housing totwist and deform the IP65 seal. Storm<strong>Force</strong> is specifically designed fortough outdoor applications such as power stations, process plantsand coastal locations.Lamps36-70W T26 (FD) linearfluorescent. Cap: G1335-49W T16 (FDH) linearfluorescent, Cap: G5Materials/FinishCanopy: Glass-fibrereinforced polyester.Diffuser: Choice of PMMA orpolycarbonate with linear prisms.Gasket: expanded polyurethaneToggles: stainless steelGear tray: steel, whiteenamelled finishInstallation/MountingCable entry positions at theback and each end of the fitting.Supplied with IP65 grommet,stainless steel toggles are captivein the canopy to prevent lossduring maintenance, and steelgear tray is retained by fingeroperated spring latches.Accessory kits for BESA boxmounting, conduit mounting,chain suspension and catenarysuspension are all available.Through wire kits can be specifiedfor use with non-emergencyversions (see accessories listing).StandardsDesigned and manufactured tocomply with EN 60598Emergency EN60598 2.22.Class I ElectricalIK09 (PC diffuser)IK02 (PMMA diffuser)IK03 (canopy)850°C fire retardant(glow wire test)IP65SpecificationTo specify state:High performance, IP65, dustand moisture proof impactresistant luminaire with areinforced GRP canopy suitablefor exposed exterior locations,polycarbonate diffuser or acrylicdiffuser, stainless steel toggles,internal steel channel, gull wingbrackets, 36-70W T26 linearfluorescent lamps or 35-49W T16linear fluorescent lamps, HF gear.As <strong>Thorn</strong> Storm<strong>Force</strong>.Key Features• Reinforced GRP Canopy• Choice of PMMA orPC diffuser• Internal steel channel• High Frequency control gear• IP65-Dust and moisture proof• Stainless steel toggles• Robust enclosure and longlife seal• Factory fitted gull wingbrackets• Emergency versions available• Dimmable versions availableon request• LSOH cable as standardStorm<strong>Force</strong>DiffuserPMMAApplications• Outdoor processing plants• Seafront areas• Piers• Transport areas• Outdoor processing plants• Power stations• Exposed coastal locationsDiffuser PCCanopyGRPUV Resistance Good Fair GoodImpact Resistance 0.2Nm 10Nm 0.35NmResistance toExcellent Good ExcellentageingSilicone free Yes Yes YesHalogen free:LuminaireInternal WiringFood gradecertification(15° angle)YesYesYesYesYesn/aYes Yes YesGlow wire test 650°C 850°C 850°CHeat resistance of 95°C 125°C 160°Cluminaire plasticsUV Transmittance 91% 89% n/a26


Ordering GuidesImpact<strong>Force</strong> Lamps must be ordered separatelyDescription Ilcos Code Socket Weight (Kg) SAP CodeT16 High Frequency versionsIMPACTF2 1X28W T16 HF L000 FDH G5 1.9 96234392IMPACTF2 1X35W T16 HF L000 FDH G5 2.3 96234404IMPACTF2 1X49W T16 HF L000 FDH G5 2.3 96234416IMPACTF2 1X54W T16 HF L000 FDH G5 1.9 96234428IMPACTF2 1X80W T16 HF L000 FDH G5 2.3 96234432IMPACTF2 2X28W T16 HF L000 FDH G5 2.6 96234436IMPACTF2 2X35W T16 HF L000 FDH G5 3.2 96234448IMPACTF2 2X49W T16 HF L000 FDH G5 3.2 96234460T16 High Frequency Through Wire versionsIMPACTF2 1x28W T16 HF TW L000 FDH G5 2.0 96234878IMPACTF2 1x35W T16 HF TW L000 FDH G5 2.4 96234879IMPACTF2 1x49W T16 HF TW L000 FDH G5 2.4 96234880IMPACTF2 1x80W T16 HF TW L000 FDH G5 2.4 96234881IMPACTF2 2x28W T16 HF TW L000 FDH G5 2.7 96234882IMPACTF2 2x35W T16 HF TW L000 FDH G5 3.3 96234883IMPACTF2 2x49W T16 HF TW L000 FDH G5 3.3 96234884T16 High Frequency Digital Dimmable versionsIMPACTF2 1X28W T16 HFD L000 FDH G5 2.3 96234394IMPACTF2 1X35W T16 HFD L000 FDH G5 2.7 96234406IMPACTF2 1X49W T16 HFD L000 FDH G5 2.7 96234418IMPACTF2 1X54W T16 HFD L000 FDH G5 2.1 96234430IMPACTF2 1X80W T16 HFD L000 FDH G5 2.8 96234434IMPACTF2 2X28W T16 HFD L000 FDH G5 3.0 96234438IMPACTF2 2X35W T16 HFD L000 FDH G5 3.6 96234450IMPACTF2 2X49W T16 HFD L000 FDH G5 4.6 96234462T16 High Frequency Digital Dimmable Though Wire versionsIMPACTF2 1x28W T16 HFD TW L000 FDH G5 2.4 96234885IMPACTF2 1x35W T16 HFD TW L000 FDH G5 2.8 96234886IMPACTF2 1x49W T16 HFD TW L000 FDH G5 2.8 96234887IMPACTF2 1x80W T16 HFD TW L000 FDH G5 2.9 96234888IMPACTF2 2x28W T16 HFD TW L000 FDH G5 3.1 96234889IMPACTF2 2x35W T16 HFD TW L000 FDH G5 3.7 96234890IMPACTF2 2x49W T16 HFD TW L000 FDH G5 4.7 96234891T16 High Frequency Emergency versionsIMPACTF2 1X28W T16 HF E3 L000 FDH G5 2.3 96234396IMPACTF2 1X35W T16 HF E3 L000 FDH G5 2.7 96234408IMPACTF2 1X49W T16 HF E3 L000 FDH G5 2.7 96234420IMPACTF2 2X28W T16 HF E3 L000 FDH G5 2.6 96234440IMPACTF2 2X35W T16 HF E3 L000 FDH G5 3.6 96234452IMPACTF2 2X49W T16 HF E3 L000 FDH G5 4.6 96234464T16 High Frequency Emergency SelfTest versionsIMPACTF2 1X28W T16 HF E3T L000 FDH G5 2.3 96234400IMPACTF2 1X35W T16 HF E3T L000 FDH G5 2.7 96234412IMPACTF2 1X49W T16 HF E3T L000 FDH G5 2.7 96234424IMPACTF2 2X28W T16 HF E3T L000 FDH G5 2.6 96234444IMPACTF2 2X35W T16 HF E3T L000 FDH G5 3.6 96234456IMPACTF2 2X49W T16 HF E3T L000 FDH G5 4.6 96234468T16 High Frequency Digital Dimmable Emergency versionsIMPACTF2 1X28W T16 HFD E3 L000 FDH G5 2.7 96234398IMPACTF2 1X35W T16 HFD E3 L000 FDH G5 3.1 96234410IMPACTF2 1X49W T16 HFD E3 L000 FDH G5 3.1 96234422IMPACTF2 2X28W T16 HFD E3 L000 FDH G5 3.4 96234442IMPACTF2 2X35W T16 HFD E3 L000 FDH G5 4.0 96234454IMPACTF2 2X49W T16 HFD E3 L000 FDH G5 4.0 96234466T16 High Frequency Digital Dimmable Emergency SelfTest versionsIMPACTF2 1X28W T16 HFD E3T L000 FDH G5 2.7 96234402IMPACTF2 1X35W T16 HFD E3T L000 FDH G5 3.1 96234414IMPACTF2 1X49W T16 HFD E3T L000 FDH G5 3.1 96234426IMPACTF2 2X28W T16 HFD E3T L000 FDH G5 3.4 96234446IMPACTF2 2X35W T16 HFD E3T L000 FDH G5 4.0 96234458IMPACTF2 2X49W T16 HFD E3T L000 FDH G5 4.0 96234470T16 High Frequency Emergency SelfTest Addressable versionsIMPACTF2 1X28W T16 HF E3X L000 FDH G5 2.3 96234947IMPACTF2 1X35W T16 HF E3X L000 FDH G5 2.7 96234948IMPACTF2 1X49W T16 HF E3X L000 FDH G5 2.7 96234949IMPACTF2 2X28W T16 HF E3X L000 FDH G5 2.6 96234950IMPACTF2 2X35W T16 HF E3X L000 FDH G5 3.6 96234951IMPACTF2 2X49W T16 HF E3X L000 FDH G5 4.6 96234952Description Ilcos Code Socket Weight (Kg) SAP CodeT26 Switchstart versionsIMPACTF2 1X18W T26 CP L000 FD G13 1.2 96234870IMPACTF2 1X36W T26 CP L000 FD G13 2.2 96234304IMPACTF2 1X58W T26 CP L000 FD G13 2.9 96234334IMPACTF2 1X70W T26 CP L000 FD G13 3.7 96234348IMPACTF2 2X18W T26 CP L000 FD G13 2.4 96234871IMPACTF2 2X36W T26 CP L000 FD G13 3.4 96234356IMPACTF2 2X58W T26 CP L000 FD G13 4.6 96234370IMPACTF2 2X70W T26 CP L000 FD G13 5.9 96234384T26 Switchstart Through Wire versionsIMPACTF2 1x36W T26 CP TW L000 FD G13 2.3 96234872IMPACTF2 1x58W T26 CP TW L000 FD G13 3.0 96234873IMPACTF2 1x70W T26 CP TW L000 FD G13 3.8 96234874IMPACTF2 2x36W T26 CP TW L000 FD G13 3.5 96234875IMPACTF2 2x58W T26 CP TW L000 FD G13 4.7 96234876IMPACTF2 2x70W T26 CP TW L000 FD G13 6.0 96234877T26 High Frequency versionsIMPACTF2 1X18W T26 HF L000 FD G13 0.9 96234892IMPACTF2 1X36W T26 HF L000 FD G13 1.9 96234306IMPACTF2 1X58W T26 HF L000 FD G13 2.5 96234336IMPACTF2 1X70W T26 HF L000 FD G13 3.3 96234350IMPACTF2 2X18W T26 HF L000 FD G13 1.6 96234893IMPACTF2 2X36W T26 HF L000 FD G13 2.6 96234358IMPACTF2 2X58W T26 HF L000 FD G13 3.2 96234372IMPACTF2 2X70W T26 HF L000 FD G13 4.6 96234386T26 High Frequency Digital Dimmable versionsIMPACTF2 1X18W T26 HFD L000 FD G13 1.5 96234894IMPACTF2 1X36W T26 HFD L000 FD G13 2.3 96234308IMPACTF2 1X58W T26 HFD L000 FD G13 2.8 96234338IMPACTF2 2X18W T26 HFD L000 FD G13 2.1 96234895IMPACTF2 2X36W T26 HFD L000 FD G13 2.8 96234360IMPACTF2 2X58W T26 HFD L000 FD G13 3.5 96234374T26 High Frequency Though wire versionsIMPACTF2 1X36W T26 HF TW L000 FD G13 2.0 96234896IMPACTF2 1X58W T26 HF TW L000 FD G13 2.6 96234897IMPACTF2 1X70W T26 HF TW L000 FD G13 3.4 96234898IMPACTF2 2X36W T26 HF TW L000 FD G13 2.7 96234899IMPACTF2 2X58W T26 HF TW L000 FD G13 3.3 96234900IMPACTF2 2X70W T26 HF TW L000 FD G13 4.7 96234901T26 High Frequency Digital Dimmable Through Wire versionsIMPACTF2 1x36W T26 HFD TW L000 FD G13 2.4 96234902IMPACTF2 1x58W T26 HFD TW L000 FD G13 2.9 96234903IMPACTF2 2x36W T26 HFD TW L000 FD G13 2.9 96234904IMPACTF2 2x58W T26 HFD TW L000 FD G13 3.6 96234905T26 High Frequency Emergency versionsIMPACTF2 1X36W T26 HF E3 L000 FD G13 2.3 96234326IMPACTF2 1X58W T26 HF E3 L000 FD G13 2.8 96234340IMPACTF2 1X70W T26 HF E3 L000 FD G13 3.6 96234352IMPACTF2 2X36W T26 HF E3 L000 FD G13 2.8 96234362IMPACTF2 2X58W T26 HF E3 L000 FD G13 3.8 96234376IMPACTF2 2X70W T26 HF E3 L000 FD G13 5.2 96234388T26 High Frequency Emergency Digital Dimmable versionsIMPACTF2 1X36W T26 HFD E3 L000 FD G13 2.7 96234328IMPACTF2 1X58W T26 HFD E3 L000 FD G13 3.3 96234342IMPACTF2 2X36W T26 HFD E3 L000 FD G13 3.4 96234364IMPACTF2 2X58W T26 HFD E3 L000 FD G13 4.0 96234378T26 High Frequency Emergency SelfTest versionsIMPACTF2 1X36W T26 HF E3T L000 FD G13 2.3 96234330IMPACTF2 1X58W T26 HF E3T L000 FD G13 2.8 96234344IMPACTF2 1X70W T26 HF E3T L000 FD G13 3.6 96234354IMPACTF2 2X36W T26 HF E3T L000 FD G13 2.8 96234366IMPACTF2 2X58W T26 HF E3T L000 FD G13 3.8 96234380IMPACTF2 2X70W T26 HF E3T L000 FD G13 5.2 96234390T26 High Frequency Digital Dimmable Emergency SelfTest versionsIMPACTF2 1X36W T26 HFD E3T L000 FD G13 2.7 96234332IMPACTF2 1X58W T26 HFD E3T L000 FD G13 3.3 96234346IMPACTF2 2X36W T26 HFD E3T L000 FD G13 3.4 96234368IMPACTF2 2X58W T26 HFD E3T L000 FD G13 4.0 96234382T26 High Frequency Emergency SelfTest Addressable versionsIMPACTF2 1X36W T26 HF E3X L000 FD G13 2.3 96234959IMPACTF2 1X58W T26 HF E3X L000 FD G13 2.8 96234960IMPACTF2 1X70W T26 HF E3X L000 FD G13 3.6 96234961IMPACTF2 2X36W T26 HF E3X L000 FD G13 2.8 96234962IMPACTF2 2X58W T26 HF E3X L000 FD G13 3.8 96234963IMPACTF2 2X70W T26 HF E3X L000 FD G13 5.2 9623496428


Corrosion<strong>Force</strong> Lamps must be ordered separatelyDescription Ilcos Code Socket Weight (Kg) SAP CodeT16 High Frequency versionsCORRF2 1X28W T16 HF L000 FDH G5 1.9 96234544CORRF2 1X35W T16 HF L000 FDH G5 2.3 96234556CORRF2 1X49W T16 HF L000 FDH G5 2.3 96234568CORRF2 1X54W T16 HF L000 FDH G5 1.9 96234580CORRF2 1X80W T16 HF L000 FDH G5 2.3 96234584CORRF2 2X28W T16 HF L000 FDH G5 2.6 96234588CORRF2 2X35W T16 HF L000 FDH G5 3.2 96234600CORRF2 2X49W T16 HF L000 FDH G5 3.2 96234612T16 High Frequency Through Wire versionsCORRF2 1X28W T16 HF TW L000 FDH G5 2.0 96234914CORRF2 1X35W T16 HF TW L000 FDH G5 2.4 96234915CORRF2 1X49W T16 HF TW L000 FDH G5 2.4 96234916CORRF2 1X80W T16 HF TW L000 FDH G5 2.4 96234917CORRF2 2X28W T16 HF TW L000 FDH G5 2.7 96234918CORRF2 2X35W T16 HF TW L000 FDH G5 3.3 96234919CORRF2 2X49W T16 HF TW L000 FDH G5 3.3 96234920T16 High Frequency Digital Dimmable versionsCORRF2 1X28W T16 HFD L000 FDH G5 2.3 96234546CORRF2 1X35W T16 HFD L000 FDH G5 2.7 96234558CORRF2 1X49W T16 HFD L000 FDH G5 2.7 96234570CORRF2 1X54W T16 HFD L000 FDH G5 2.1 96234582CORRF2 1X80W T16 HFD L000 FDH G5 2.8 96234586CORRF2 2X28W T16 HFD L000 FDH G5 3.0 96234590CORRF2 2X35W T16 HFD L000 FDH G5 3.6 96234602CORRF2 2X49W T16 HFD L000 FDH G5 4.6 96234614T16 High Frequency Digital Dimmable Though Wire versionsCORRF2 1X28W T16 HFD TW L000 FDH G5 2.4 96234921CORRF2 1X35W T16 HFD TW L000 FDH G5 2.8 96234922CORRF2 1X49W T16 HFD TW L000 FDH G5 2.8 96234923CORRF2 1X80W T16 HFD TW L000 FDH G5 2.9 96234924CORRF2 2X28W T16 HFD TW L000 FDH G5 3.1 96234925CORRF2 2X35W T16 HFD TW L000 FDH G5 3.7 96234926CORRF2 2X49W T16 HFD TW L000 FDH G5 4.7 96234927T16 High Frequency Emergency versionsCORRF2 1X28W T16 HF E3 L000 FDH G5 2.3 96234548CORRF2 1X35W T16 HF E3 L000 FDH G5 2.7 96234560CORRF2 1X49W T16 HF E3 L000 FDH G5 2.7 96234572CORRF2 2X28W T16 HF E3 L000 FDH G5 2.6 96234592CORRF2 2X35W T16 HF E3 L000 FDH G5 3.6 96234604CORRF2 2X49W T16 HF E3 L000 FDH G5 4.6 96234616T16 High Frequency Digital Dimmable Emergency versionsCORRF2 1X28W T16 HFD E3 L000 FDH G5 2.3 96234550CORRF2 1X35W T16 HFD E3 L000 FDH G5 2.7 96234562CORRF2 1X49W T16 HFD E3 L000 FDH G5 2.7 96234574CORRF2 2X28W T16 HFD E3 L000 FDH G5 2.6 96234594CORRF2 2X35W T16 HFD E3 L000 FDH G5 3.6 96234606CORRF2 2X49W T16 HFD E3 L000 FDH G5 4.6 96234618T16 High Frequency Emergency SelfTest versionsCORRF2 1X28W T16 HF E3T L000 FDH G5 2.7 96234552CORRF2 1X35W T16 HF E3T L000 FDH G5 3.1 96234564CORRF2 1X49W T16 HF E3T L000 FDH G5 3.1 96234576CORRF2 2X28W T16 HF E3T L000 FDH G5 3.4 96234596CORRF2 2X35W T16 HF E3T L000 FDH G5 4.0 96234608CORRF2 2X49W T16 HF E3T L000 FDH G5 4.0 96234620T16 High Frequency Digital Dimmable Emergency SelfTest versionsCORRF2 1X28W T16 HFD E3T L000 FDH G5 2.7 96234554CORRF2 1X35W T16 HFD E3T L000 FDH G5 3.1 96234566CORRF2 1X49W T16 HFD E3T L000 FDH G5 3.1 96234578CORRF2 2X28W T16 HFD E3T L000 FDH G5 3.4 96234598CORRF2 2X35W T16 HFD E3T L000 FDH G5 4.0 96234610CORRF2 2X49W T16 HFD E3T L000 FDH G5 4.0 96234622T16 High Frequency Emergency SelfTest Addressable versionsCORRF2 1X28W T16 HF E3X L000 FDH G5 2.3 96234968CORRF2 1X35W T16 HF E3X L000 FDH G5 2.7 96234969CORRF2 1X49W T16 HF E3X L000 FDH G5 2.7 96234970CORRF2 2X28W T16 HF E3X L000 FDH G5 2.6 96234971CORRF2 2X35W T16 HF E3X L000 FDH G5 3.6 96234972CORRF2 2X49W T16 HF E3X L000 FDH G5 4.6 96234973Description Ilcos Code Socket Weight (Kg) SAP CodeT26 Switchstart versionsCORRF2 1X18W T26 CP L000 FD G13 1.2 96234906CORRF2 1X36W T26 CP L000 FD G13 2.2 96234472CORRF2 1X58W T26 CP L000 FD G13 2.9 96234486CORRF2 1X70W T26 CP L000 FD G13 3.7 96234500CORRF2 2X18W T26 CP L000 FD G13 2.4 96234907CORRF2 2X36W T26 CP L000 FD G13 3.4 96234508CORRF2 2X58W T26 CP L000 FD G13 4.6 96234522CORRF2 2X70W T26 CP L000 FD G13 5.9 96234536T26 Switchstart Through Wire versionsCORRF2 1X36W T26 CP TW L000 FD G13 2.3 96234908CORRF2 1X58W T26 CP TW L000 FD G13 3.0 96234909CORRF2 1X70W T26 CP TW L000 FD G13 3.8 96234910CORRF2 2X36W T26 CP TW L000 FD G13 3.5 96234911CORRF2 2X58W T26 CP TW L000 FD G13 4.7 96234912CORRF2 2X70W T26 CP TW L000 FD G13 6.0 96234913T26 High Frequency versionsCORRF2 1X18W T26 HF L000 FD G13 0.9 96234928CORRF2 1X36W T26 HF L000 FD G13 1.9 96234474CORRF2 1X58W T26 HF L000 FD G13 2.5 96234488CORRF2 1X70W T26 HF L000 FD G13 3.3 96234502CORRF2 2X18W T26 HF L000 FD G13 1.6 96234929CORRF2 2X36W T26 HF L000 FD G13 2.6 96234510CORRF2 2X58W T26 HF L000 FD G13 3.2 96234524CORRF2 2X70W T26 HF L000 FD G13 4.6 96234538T26 High Frequency Digital Dimmable versionsCORRF2 1X18W T26 HFD L000 FD G13 1.5 96234930CORRF2 1X36W T26 HFD L000 FD G13 2.3 96234476CORRF2 1X58W T26 HFD L000 FD G13 2.8 96234490CORRF2 2X18W T26 HFD L000 FD G13 2.1 96234931CORRF2 2X36W T26 HFD L000 FD G13 2.8 96234512CORRF2 2X58W T26 HFD L000 FD G13 3.5 96234526T26 High Frequency Though wire versionsCORRF2 1X36W T26 HF TW L000 FD G13 2.0 96234932CORRF2 1X58W T26 HF TW L000 FD G13 2.6 96234933CORRF2 1X70W T26 HF TW L000 FD G13 2.4 96234934CORRF2 2X36W T26 HF TW L000 FD G13 2.7 96234935CORRF2 2X58W T26 HF TW L000 FD G13 3.3 96234936CORRF2 2X70W T26 HF TW L000 FD G13 3.3 96234937T26 High Frequency Digital Dimmable Through Wire versionsCORRF2 1X36W T26 HFD TW L000 FD G13 2.4 96234938CORRF2 1X58W T26 HFD TW L000 FD G13 2.9 96234939CORRF2 2X36W T26 HFD TW L000 FD G13 2.9 96234940CORRF2 2X58W T26 HFD TW L000 FD G13 3.6 96234941T26 High Frequency Emergency versionsCORRF2 1X36W T26 HF E3 L000 FD G13 2.3 96234478CORRF2 1X58W T26 HF E3 L000 FD G13 2.8 96234492CORRF2 1X70W T26 HF E3 L000 FD G13 3.6 96234504CORRF2 2X36W T26 HF E3 L000 FD G13 2.8 96234514CORRF2 2X58W T26 HF E3 L000 FD G13 3.8 96234528CORRF2 2X70W T26 HF E3 L000 FD G13 5.2 96234540T26 High Frequency Emergency Digital Dimmable versionsCORRF2 1X36W T26 HFD E3 L000 FD G13 2.7 96234480CORRF2 1X58W T26 HFD E3 L000 FD G13 3.3 96234494CORRF2 2X36W T26 HFD E3 L000 FD G13 3.4 96234516CORRF2 2X58W T26 HFD E3 L000 FD G13 4.0 96234530T26 High Frequency Emergency SelfTest versionsCORRF2 1X36W T26 HF E3T L000 FD G13 2.3 96234482CORRF2 1X58W T26 HF E3T L000 FD G13 2.8 96234496CORRF2 1X70W T26 HF E3T L000 FD G13 3.6 96234506CORRF2 2X36W T26 HF E3T L000 FD G13 2.8 96234518CORRF2 2X58W T26 HF E3T L000 FD G13 3.8 96234532CORRF2 2X70W T26 HF E3T L000 FD G13 5.2 96234542T26 High Frequency Digital Dimmable Emergency SelfTest versionsCORRF2 1X36W T26 HFD E3T L000 FD G13 2.7 96234484CORRF2 1X58W T26 HFD E3T L000 FD G13 3.3 96234498CORRF2 2X36W T26 HFD E3T L000 FD G13 3.4 96234520CORRF2 2X58W T26 HFD E3T L000 FD G13 4.0 96234534T26 High Frequency Emergency SelfTest Addressable versionsCORRF2 1X36W T26 HF E3X L000 FD G13 2.3 96234974CORRF2 1X58W T26 HF E3X L000 FD G13 2.8 96234975CORRF2 1X70W T26 HF E3X L000 FD G13 3.6 96234976CORRF2 2X36W T26 HF E3X L000 FD G13 2.8 96234977CORRF2 2X58W T26 HF E3X L000 FD G13 3.8 96234978CORRF2 2X70W T26 HF E3X L000 FD G13 5.2 9623497929


Ordering GuidesAccessoriesCold<strong>Force</strong> Lamps must be ordered separatelyDescription Ilcos Code Socket Weight (Kg) SAP CodeT26 High Frequency versionsCOLDF2 1X36W T26/38 HF TT L000 FD G13 1.88 96234623COLDF2 1X58W T26/38 HF TT L000 FD G13 2.45 96234624COLDF2 2X36W T26/38 HF TT L000 FD G13 2.62 96234625COLDF2 2X58W T26/38 HF TT L000 FD G13 3.17 96234626Heat<strong>Force</strong> Lamps must be ordered separatelyDescription Ilcos Code Socket Weight (Kg) SAP CodeT26 High Frequency versionsHEATF2 1X36W T26 HF HT L000 FD G13 1.88 96234627HEATF2 1X58W T26 HF HT L000 FD G13 2.45 96234628Storm<strong>Force</strong> Lamps must be ordered separatelyDescription Ilcos Code Socket Weight (Kg) SAP CodePMMA DiffuserT16 High Frequency versionsSTORMF2 AC 2X35W T16 HF L000 FDH G5 5.0 96234965STORMF2 AC 2X49W T16 HF L000 FDH G5 5.0 96234966T26 High Frequency versionsSTORMF2 AC 2X36W T26 HF L000 FDH G13 4.2 96234981STORMF2 AC 2X58W T26 HF L000 FDH G13 5.6 96234982STORMF2 AC 2X70W T26 HF L000 FDH G13 7.0 96234967PC DiffuserT16 High Frequency versionsSTORMF2 PC 2X35W T16 HF L000 FDH G5 5.0 96234983STORMF2 PC 2X49W T16 HF L000 FDH G5 5.0 96234984T26 High Frequency versionsSTORMF2 PC 2X36W T26 HF L000 FDH G13 4.2 96234944STORMF2 PC 2X58W T26 HF L000 FDH G13 5.6 96234945STORMF2 PC 2X70W T26 HF L000 FDH G13 7.0 96234985EmergencySTORMF2 PC 2X36W T26 HF E3 L000 FD G13 5.2 96235726STORMF2 PC 2X58W T26 HF E3 L000 FD G13 6.5 96235727Accessories Ordering GuideDescriptionSAP CodeFORCE2 28/36 TW KIT* THROUGH WIRE KIT 28/36W 96503163FORCE2 35/49/58 TW KIT* THROUGH WIRE KIT 35/49/58W 96503164FORCE2 70 TW KIT* THROUGH WIRE KIT 70W 96503165FORCE2 FIX KIT QUICK FIT BRACKET (PAIR) 96503166FORCE2 FIX/CH KIT CHAIN SUSPENSION KITS (5 PAIRS) 96503167FORCE2 28/36 RS CLIP KIT STAINLESS STEEL TOGGLES 96503157FORCE2 35/49/58 RS CLIP KIT STAINLESS STEEL TOGGLES 96503158FORCE2 70 RS CLIP KIT STAINLESS STEEL TOGGLES 96503159FORCE2 28/36 PC CLIP KIT POLYCARBONATE TOGGLES 96503160FORCE2 35/49/58 PC CLIP KIT POLYCARBONATE TOGGLES 96503161*Only suitable for use with non-emergency versionsDescriptionSAP CodeFORCE2 70 PC CLIP KIT POLYCARBONATE TOGGLES 96503162FORCE2 MCA KIT CATENARY SUSPENSION KIT 96233817FORCE2 MRS KIT CONDUIT KIT 96503169FORCE2 BESA KIT BESA BOX KIT 96503168XFORCE2 R 1X28/36/54 REFLECTOR FOR SINGLE 28/36/54W 96235134XFORCE2 R 1X35/49/58/80 REFLECTOR FOR SINGLE 35/49/58/80W 96235135XFORCE2 R 2X28/36 REFLECTOR FOR TWIN 28/36W 96235136XFORCE2 R 2X35/49/58 REFLECTOR FOR TWIN 35/49/58W 96235137Stainless steel togglesChain fixing kit (Fix/Ch kit) Quick fix bracket (Fix kit) BESA kitThrough wire kit Polycarbonate toggles (PC Clip kit) MRS kit Reflector30


PhotometricsDimensions32150°Cd/1000lm150°150°Cd/1000lm150°150°Cd/1000lm150°113111120°120°120°120°120°120°90° 180 120 60 90°90° 180 120 60 90°90° 180 120 60 90°2873477209003260°30°30°0°Corrosion<strong>Force</strong> IILamp: 1x 58W T26LOR: 0.79 ULOR: 0.16 DLOR: 0.6260°60°30°30°0°Corrosion<strong>Force</strong> IILamp: 1x 35W T16LOR: 0.93 ULOR: 0.19 DLOR: 0.7360°60°30°30°0°Heat<strong>Force</strong> IILamp: 1x 58W T26LOR: 0.81 ULOR: 0.16 DLOR: 0.6560°1241841294 28/54W1594 35/49/80WSingle T16 version15621670150°Cd/1000lm150°150°Cd/1000lm150°150°Cd/1000lm150°166125120°120°120°120°120°120°2873477209003290° 120 80 40 90°90° 180 120 60 90°90° 180 120 60 90°60°60°60°60°60°60°12418415621630°0°30°30°0°30°30°0°30°1294 28W1594 35/49WCorrosion<strong>Force</strong> IILamp: 2x 58W T26LOR: 0.67 ULOR: 0.11 DLOR: 0.56Impact<strong>Force</strong> IILamp: 1x 35W T16LOR: 0.91 ULOR: 0.19 DLOR: 0.72Corrosion<strong>Force</strong> IILamp: 2x 35W T16LOR: 0.81 ULOR: 0.14 DLOR: 0.68Twin T16 version32150°Cd/1000lm150°150°Cd/1000lm150°150°Cd/1000lm150°111113120°120°120°120°120°120°90° 180 120 60 90°90° 180 120 60 90°90° 180 120 60 90°17728734734733072090011643260°30°30°0°Impact<strong>Force</strong> IILamp: 1x 58W T26LOR: 0.75 ULOR: 0.16 DLOR: 0.5960°60°30°30°0°Heat<strong>Force</strong> IILamp: 1x 36W T26LOR: 0.81 ULOR: 0.16 DLOR: 0.6560°60°30°30°0°Impact<strong>Force</strong> IILamp: 2x 35W T16LOR: 0.77 ULOR: 0.13 DLOR: 0.6460°74124184184684 18W1294 36W1594 58W1859 70WSingle T26 version10615621621670150°Cd/1000lm150°150°Cd/1000lm150°150°Cd/1000lm150°166125120°120°120°120°120°120°17728734734733072090011643290° 120 80 40 90°90° 120 80 40 90°90° 180 120 60 90°60°30°0°30°60°60°30°0°30°60°60°30°0°30°60°74124184184684 18W1294 36W1594 58W1859 70W106156216216Impact<strong>Force</strong> IILamp: 2x 58W T26LOR: 0.63 ULOR: 0.10 DLOR: 0.52Cold<strong>Force</strong> IILamp: 1x 58W T26LOR: 0.66 ULOR: 0.15 DLOR: 0.51Cold<strong>Force</strong> IILamp: 2x 58W T26LOR: 0.52 ULOR: 0.09 DLOR: 0.43Twin T26 version31


<strong>Lighting</strong> people and places<strong>Thorn</strong> <strong>Lighting</strong> Main OfficesAustralia<strong>Thorn</strong> <strong>Lighting</strong> Pty Limited43 Newton Road, Wetherill ParkNSW 2164Tel: (02) 8786 6000Fax: (02) 9612 2700E-mail: infoaustralia@thornlighting.comWebsite: www.thornlighting.com.auAustria<strong>Thorn</strong> Licht GmbHDonau-City-Straße 11,1220 Wien, AustriaTel: (43) 1 202 66 11Fax: (43) 1 202 66 11 12E-mail: office.at@thornlighting.comWebsite: www.thornlighting.atChina<strong>Thorn</strong> <strong>Lighting</strong> (Guangzhou) Operations Ltd,No.12 Lian Yun Road, Eastern Section,GETDD, Guangzhou 510530, ChinaTel: (86) 20 3228 2706Fax: (86) 20 3228 1777E-mail: sales.cn@thornlighting.com<strong>Thorn</strong> <strong>Lighting</strong> (Tianjin) Co. Ltd332 Hongqi Road, Tianjin 300190,ChinaTel: (86) 22 8369 2303Fax: (86) 22 8369 2302E-mail: info.tj@thornlighting.comCzech Republic<strong>Thorn</strong> <strong>Lighting</strong> CS spol. s.r.o.,Na Březince 6/930, 150 00 Praha 5Czech RepublicTel: (420) 224 315 252Fax: (420) 233 326 313E-mail: thorn.cz@thornlighting.comWebsite: www.thornlighting.czDenmark<strong>Thorn</strong> <strong>Lighting</strong> A/SAlbuen 44, 6000 Kolding, DenmarkTel: (45) 7696 3600Fax: (45) 7696 3601E-mail: info.dk@thornlighting.comWebsite: www.thornlighting.dkFrance<strong>Thorn</strong> Europhane SA156 Boulevard Haussmann,Cedex 08, Paris 75379, FranceTel: (33) 1 49 53 6262Fax: (33) 1 49 53 6240Website: www.thornlighting.frHong Kong<strong>Thorn</strong> <strong>Lighting</strong> (Hong Kong) LimitedUnit 4301, Level 43, Tower 1,Metroplaza,223 Hing Fong Road,Kwai Chung, N.T., Hong KongTel: (852) 2578 4303Fax: (852) 2887 0247E-mail: info.hk@thornlighting.comIndia<strong>Thorn</strong> <strong>Lighting</strong> India Pvt. LtdRH-2 Nirav CHS, 636A, 90 Ft. D.P. Road,Near Thakur Polytechnic400 101 Mumbai, IndiaTel: (91) 22285 41056Fax: (91) 22285 1120E-mail: international_sales@thornlighting.comWebsite: www.thornlighting.comIreland<strong>Thorn</strong> <strong>Lighting</strong> (Ireland) Limited320 Harold’s Cross Road,Dublin 6W, IrelandTel: (353) 1 4922 877Fax: (353) 1 4922 724E-mail: dublinsales@thornlighting.comWebsite: www.thornlighting.co.ukItaly<strong>Thorn</strong> Europhane SpaVia G Di Vittorio, 2, Cadriano di Granarolo,Bologna 40057, ItalyTel: (39) 051 763391Fax: (39) 051 763088E-mail: info@thornlighting.itWebsite: www.thornlighting.itNew Zealand<strong>Thorn</strong> <strong>Lighting</strong> (NZ) Ltd399 Rosebank Road, Avondale, Auckland 1026PO Box 71134, Rosebank, Auckland 1348Tel: (64) 9 828 7155Fax: (64) 9 828 7591E-mail: info.NZ@thornlighting.comWebsite: www.thornlighting.co.nzNorway<strong>Thorn</strong> <strong>Lighting</strong> ASStrømsveien 344, 1081 Oslo,NorwayTel: (47) 22 82 07 00Fax: (47) 22 82 07 01E-mail: info.no@thornlighting.comWebsite: www.thornlighting.noPoland<strong>Thorn</strong> <strong>Lighting</strong> Polska Sp.z.o.o.,Ul. Gazowa 26A, Wrocław 50-513,PolandTel: (48) 71 7833 740Fax: (48) 71 3366 029E-mail: thorn.pl@thornlighting.comWebsite: www.thornlighting.plRussia<strong>Thorn</strong> <strong>Lighting</strong>Novoslobodskaya Str., 21, office 406Business Center “Novoslobodskaya 21”,Moscow 127030, RussiaTel: (7) 495 981 35 41Fax: (7) 495 981 35 42E-mail: anna.kisteneva@thornlighting.comWebsite: www.thornlighting.ruSingapore<strong>Thorn</strong> <strong>Lighting</strong> (Singapore) Pte Ltd5 Kaki Bukit Crescent, 04-02 KoyotechBuilding, 416238 SingaporeTel: (65) 6844 5800Fax: (65) 6745 7707E-mail: info.sg@thornlighting.comSweden<strong>Thorn</strong> <strong>Lighting</strong> ABIndustrigatan, Box 305, SE-261 23Landskrona, SwedenTel: (46) 418 520 00Fax: (46) 418 265 74E-mail: info.se@thornlighting.comWebsite: www.thornlighting.seUnited Arab Emirates<strong>Thorn</strong> <strong>Lighting</strong> Ltd DubaiAl Shoala Building, Office 301,Block E, Airport road, P.O. Box 1200,Deira, Dubai, UAETel: (971) 4 2940181Fax: (971) 4 2948838E-mail: tlluae@emirates.net.aeWebsite: www.thornlighting.com<strong>Thorn</strong> Gulf LLCAl Shoala Building, Office 301/2, Block E,Airport road, P.O. Box 22672, Deira,Dubai, UAETel: (971) 4 2948938Fax: (971) 4 2948838E-mail: thorng@emirates.net.aeWebsite: www.thornlighting.comUnited Kingdom<strong>Thorn</strong> <strong>Lighting</strong> LimitedSilver Screens, Elstree Way, Borehamwood,Hertfordshire, WD6 1FE, UKTel: (44) 20 8732 9800Fax: (44) 20 8732 9801E-mail: brochures.uk@thornlighting.com<strong>Thorn</strong> Olympics Sports <strong>Lighting</strong> TeamTel: 07785 251 438E-mail: olympics.team@thornlighting.comWebsite: www.thornlighting.co.ukInternational Sales<strong>Thorn</strong> <strong>Lighting</strong> LimitedSilver Screens, Elstree Way, Borehamwood,Hertfordshire, WD6 1FE, UKTel: (44) 20 8732 1915Fax: (44) 20 8732 1911E-mail: international_sales@thornlighting.comWebsite: www.thornlighting.comwww.thornlighting.com<strong>Thorn</strong> <strong>Lighting</strong> is constantly developing and improving its products. All descriptions, illustrations, drawings and specifications in this publication present only general particulars and shall not form partof any contract. The right is reserved to change specifications without prior notification or public announcement. All goods supplied by the company are supplied subject to the company’s GeneralConditions of Sale, a copy of which is available on request. All measurements are in millimetres and weights in kilograms unless otherwise stated.Publication No: 409 (INT) Publication Date: 07/08