RepairPressure Control KnobRemoval1. Engage trigger lock and put prime/pressure reliefvalve in UP position to relieve pressure.InstallationNOTE: Inlet valve must be fully installed before outletvalve can be installed.1. Make sure prime/pressure relief valve is in UP position.Use a thin screwdriver or allen wrench to turnoutlet valve counter-clockwise until it touches inletball. DO NOT TIGHTEN. Outlet valve should onlybe threaded until inlet ball does not move whentouched.ti19350ati19347a2. Loosen two set screws (34) from pressure controlknob and remove knob.ti19347a34ti19616ati19620a2. Install pressure control knob. Turn knob fully counter-clockwise(“0” setting will line up with red dot).Torque set screws (34) to 40 in-lb (4.5 N•m).34ti19620ati19351a30 <strong>3A2308A</strong>