12.07.2015 Views

EPR – Areva brochure

EPR – Areva brochure

EPR – Areva brochure

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

2 t+8.50m123456128615243645413152326541096212512111210398743610928746561524321+12.76m21817654432312■ <strong>EPR</strong> NUCLEAR ISLANDNuclear Island building arrangementMiscellaneous plan viewREACTOR BUILDING+ 57.50SAFEGUARDBUILDINGDIVISION 2SAFEGUARDBUILDINGDIVISION 3I & C SERVICE CENTERTECHNICAL SUPPORT CENTERDOCUMENTATION ROOMSHIFT OFFICETOILETSKITCHEN+ 33.100.00<strong>–</strong> 9.60FUEL BUILDINGFUEL STORAGE POOLTRANSFER STATION+29.00mSPENT FUELMAST BRIGDEPIPEDUCTPIPEVALVE VALVE DUCTEBS<strong>–</strong>TANK ROOM ROOMPIPECVCS PUMP DUCTEBS PUMPSUMP<strong>–</strong>4.35+19.50+13.80+5.15+1.50<strong>–</strong>2.30+38.60+34.45+33.80STORAGE AREAFOR RPV <strong>–</strong>CLOSURE H.+19.65INCOREINSTRUMENT.+14.97STORAGESPRAYPOOLVALVES+10.00+9.80+7.44+7.44 SPRAY+6.95+6.30LINES+4.64 +5.64SG <strong>–</strong> BLOW DOWNSYSTEMCVCS+1.50CVCS<strong>–</strong>2.30<strong>–</strong>5.35SPREADINGIRWSTAREA<strong>–</strong>7.800 246810 20m+28.50+24.10+19.50+13.80+8.70+5.15<strong>–</strong>6.15+2.60SIC SSUPPLY AIRINLETI & CSIS/RHRVALVEROOMLHSIPUMPSAFEGUARD BUILDINGDIVISION 2IODINE FILT./AIR COND. MCR+ 30.50AIR DUCTCABLEFLOORSMOKEEXTRAC.SYSTEMTECHNICALMAIN CONTROL ROOM SUPPORTCENTERCABLEBATTERIESFLOOR220 VCABINETSSWITCHGEARSCABLEFLOORPERSONNEL+1.50AIR LOCKLHSI/RHR<strong>–</strong>HXKT/RPE<strong>–</strong>11.70CABLE<strong>–</strong>SHAFTEFWSWATER TANKEFWS PUMPEXH.AIR+ 26.700.00<strong>–</strong> 8.60SAFEGUARDBUILDINGDIVISION 1EFWS PUMPCCWS PUMPANTEROOMSERVICE CORRIDORPASSAGEWAYMHSI PUMPSUMPVALVELHSI PUMPCHRS PUMPAIRLOCKCHRSSUMP VALVESURVEIL.SYSTEM+13.80+13.80mACCUACCULOADINGPITMAIN CONTROL ROOMMCRENTRANCEHATCHTAGGING ROOMSICS 1/COMPUTER ROOM 1 SICS 2 /COMPUTER ROOM 2+13.80+9.70m+13.80+13.80+13.80+11.10+13.80+11.10HVAC DISTRIBUTION+14.97 +14.97INCOREINSTRUMEN.+12.36+13.80STORAGEPOOLTRANSFER PIT+5.10mPRESSU-RIZER+6.30m+7.44+12.36+11.10+13.80+11.10+13.80+13.80TOOLS SPAREPARTSHVAC DISTRIBUTIONKLA/EBAFILTERS+13.80+13.80DECONT SYSTEMFOR RCPACCUKLA/EBAFANACCUACCESSCONTROLROOM+13.80PIPE DUCT5 4 37 610 9VAPOURCOMPRESSORVAPOURCOMPRESSORVAPOURCOMPRESSORCONDENSER ANDSWITCHGEARSI&C CABINETS+8.107 83 14 3SAFEGUARDBUILDINGDIVISION 45 42 1SWITCHGEARS3 1I&C CABINETSSERVICE CORRIDORBATTERIES 220 VIODINE FAN+17.30mIODINE FANMONITOR AIRACTIVITYEXHAUST BOOSTERFANS+16.70mSPENT FUEL STORAGE POOLGASCOOLERHEPA FILTERS+16.70mVALVE ROOMBORONPREPARATIONTANKDELAY BEDSHEPA FILTERS0 246810 20mFUEL BUILDINGMATERIAL LOCKNUCLEAR AUXILIARYBUILDING† The <strong>EPR</strong> layout offers exceptional andunique resistance to external hazards,especially earthquake and airplane crash.• To withstand major earthquake, the entireNuclear Island stands on a single thickreinforced concrete basemat. Buildingheight has been minimized and heavycomponents and water tanks are locatedat the lowest possible level.• To withstand large airplane crash, theReactor Building, Spent Fuel Buildingand two of the four Safeguard Buildingsare protected by an outer shell madeof reinforced concrete. The othertwo Safeguard Buildings are protectedby a geographical separation. Similarly,the Diesel generators are locatedin two geographically separate buildingsto avoid common failures.The outer shell (in blue in the image) protects the Reactor Building, the Spent Fuel Buildingand two of the four Safeguard Buildings including the control room.† The <strong>EPR</strong> Nuclear Island design has undisputed advantages for operators,especially where radiation protection and ease of maintenance are concerned.• The layout is optimized and based on the strict separation of redundant systems.• The distinction between access-controlled areas containing radioactiveequipment and non-controlled areas significantly contributes to reduceexposure of the operating personnel.• Maintenance requirements were systematically taken into account at the earlieststage of the design. For example, large setdown areas have been designed tomake maintenance operations easier for operating personnel.12 II 13

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!