<strong>POE</strong>-<strong>D10</strong>-<strong>00</strong>-E-12SAFETY STANDARDS REGULATED, REINFORCEDINSULATION TYPE, AH SERIESVer: 12 Page: 13 / 18No Items Performance Testing methodThe specimens shall be individually wrapped in at least one butmore than two complete layers of cheesecloth. The specimens shallbe subjected to 20 discharges. The interval between successivedischarges shall be 5 sec. The UAC shall be maintained for 2 minafter the last discharge.Fig. 67.3.16ActiveFlammabilityThe cheesecloth shallnot be on fire.7.3.17 Passive FlammabilityThe burning timeshall not be exceededthe time 30 sec. Thetissue paper shall notignite.The capacitor under test shall be held in the position which bestpromotes burning. Each specimen shall only be exposed once toflame. Time of exposure to flame: 30sec.Length of flame : 12±1mmGas burner : Length 35mm min.Inside Dia. : 0.5±0.1mmOutside Dia. : 0.9mm max.Gas : Butane gas Purity 95% min.Fig. 77.3.18Temperature CycleAppearanceNo marked defectChar. Cap. DF / QChange<strong>SL</strong>, ≦±5% Q≧275+5/2C (C<strong>CH</strong>