CONVENTIONAL DEVICES System Sensor i3 Series - Secutron

CONVENTIONAL DEVICES System Sensor i3 Series - Secutron

CONVENTIONAL DEVICES System Sensor i3 Series - Secutron

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>CONVENTIONAL</strong> <strong>DEVICES</strong><strong>System</strong> <strong>Sensor</strong> i 3 <strong>Series</strong>Reversing Relay/Synchronization ModuleFeatures• Compatible with 2- and 4-wire <strong>i3</strong> detectorsequipped with a sounder• Activates all <strong>i3</strong> sounders on a loop when onealarms• Synchronizes all <strong>i3</strong> sounders on the loop for aclear alarm signal• Can be used with bell/alarm, alarm relay, orNAC outputs• Includes a field-selectable switch toaccommodate both coded and continuousalarm signals• Allows <strong>i3</strong> detector silencing from the panel orkeypad• Operates on 12 and 24-volt systems• Quick-connect harness and color coded wiresfacilitate connectionsDescriptionThe CRRS-MODA reversing relay/synchronizationmodule enhances the operation of 2 and 4-wire <strong>i3</strong>series detectors equipped with a sounder.Installation EaseThe CRRS-MODA includes a Velcro attachmentfor easy installation into the fire alarm control panelcabinet. A quick-connect harness and color-codedwires simplify connections.IntelligenceThe CRRS-MODA’s design is flexible to accommodatevirtually any application. The CRRS-MODA iscompatible with both 2 and 4-wire <strong>i3</strong> series detectorsoperating over 12V and 24V systems. The module canbe used with either bell/alarm, alarm relay, or NACoutputs, and its field-selectable switch accommodatesboth coded and continuous alarm signals.Instant InspectionTo meet fire alarm requirements, the CRRS-MODAactivates all <strong>i3</strong> sounders on a loop when one alarms.Additionally, the CRRS-MODA synchronizes the outputof the <strong>i3</strong> sounders, regardless of whether the panel’salarm signal is continuous or coded, to ensure a clearalarm signal.Engineering SpecificationsReversing relay/synchronization module shall bea an <strong>i3</strong> <strong>Series</strong> model number CRRS-MODA, listedto Underwriters Laboratories as a smoke detectoraccessory. The module shall allow all 2-wire and4-wire <strong>i3</strong> <strong>Series</strong> detectors equipped with a sounder ona loop to sound when one alarms. The module shallprovide a switch to toggle between coded mode andcontinuous mode. When in coded mode, the moduleshall synchronize the <strong>i3</strong> sounders on the loop to mirrorthe input signal. When in continuous mode, the moduleshall synchronize the <strong>i3</strong> sounders on the loop to theANSI S3.41 temporal coded pattern. In either codedor continuous modes, the CRRS-MODA module shallpermit sounders to be silenced at the panel. The CRRS-MODA module shall operate between 8.5 and 35 VDC,and shall provide 18 AWG stranded, tinned conductorsconnected to a quick-connect harness.Issue 1 SECUTRON INC.Page 1 of 2Canada 25 Interchange Way, Vaughan (Toronto), Ontario L4K 5W3 Telephone: (905) 695-3545 Fax: (905) 660-4113 • Web Page: www.secutron.comU.S.A. 4575 Witmer Industrial Estates, Niagara Falls, NY 14305 Telephone: (888) 695-3545 Fax: (888) 660-4113 • E-mail: mail@secutron.comCatalog Number 2049 • Not to be used for installation purposes.


Electrical SpecificationsPhysical SpecificationsOperating VoltageNominalMinimumMaximumAvg. Operating Current25 mARelay Contact Rating2 A @ 35 VDC12/24 V8.5 V35 VOperating Temperature Range32°F–131°F (0°C–55°C)DimensionsHeight2.5 inches (63 mm)Width2.5 inches (63 mm)Depth1 inch (25 mm)Operating Humidity Range5 to 85% non-condensingWire Connections18 AWG stranded, tinned, 16” long2-Wire <strong>System</strong> Triggered from Alarm/Bell Circuit:ULC LISTEDALARMCONTROLPANELBELL/ALARMCIRCUIT(positive signalin alarm state)PURPLET+EOL2–WIRE +INITIATINGDEVICE–CIRCUITYELLOWIN+ORANGEIN–BROWNOUT+WHITEOUT–1 + IN2 + OUT3 - IN/OUT4 RA+1 + IN2 + OUT3 - IN/OUT4 RA+5 RA-5 RA-+AUX POWER–REDPWR+BLACKPWR–OPTIONALREMOTEANNUNCIATOR(RA400Z)2-Wire <strong>System</strong> Triggered from Alarm Relay Contact:ULC LISTEDALARMCONTROLPANEL+–+–OPTIONALREMOTEANNUNCIATOR(RA400Z)NOTE:These diagrams representtwo common wiring methods.Refer to the CRRS-MODAinstallation manual for additionalwiring configurations.ALARMRELAY(NO Contact)PURPLET+EOL2–WIRE +INITIATINGDEVICE–CIRCUITYELLOWIN+ORANGEIN–BROWNOUT+WHITEOUT–1 + IN2 + OUT3 - IN/OUT4 RA+1 + IN2 + OUT3 - IN/OUT4 RA+5 RA-5 RA-+++AUX POWER–REDPWR+BLACKPWR––OPTIONALREMOTEANNUNCIATOR(RA400Z)–OPTIONALREMOTEANNUNCIATOR(RA400Z)Ordering InformationModel NumberCRRS-MODADescriptionReversing relay/synchronization module for <strong>i3</strong> series smoke detectorsPage 2 of 2 SECUTRON INC.Catalog Number 2049 • Not to be used for installation purposes.Issue 1<strong>Secutron</strong> reserves the right to make changes at any time without notice in prices, colors, materials, components, equipment, specifications and models and also to discontinue models.Modul-R ® is a trademark of <strong>Secutron</strong> Inc.ISO 9001: 2000REGISTERED

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!