12.07.2015 Views

PRIMERGY RX200 S4 - Nettailer

PRIMERGY RX200 S4 - Nettailer

PRIMERGY RX200 S4 - Nettailer

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

System configurator and order-information guideB <strong>PRIMERGY</strong> <strong>RX200</strong> <strong>S4</strong> Status 2009-05-28Base unit without CPU and Memory S26361-K1167-V101Rack version for 19'' racks with1 hot plug power supply moduleNo Rack-mounting kit includedFor an orderable basic unit one CPU = first CPU,one memory = first memory as well as one of twopossible rack-mount kit options has to be selectedS26113-F527-E12nd redundant PSU module For later conversion the following kit is available:for redundancy 1.) 1 power supply module hot plug S26113-F527-L1uses hot plug PSU slot incl. power cordmax. 1x per systemS26361-F2735-E101 S26361-F2735-E110 S26361-F2735-E111RMK-F1_1-2U Server RMK-P_1-2U Server No Rackmount-Kit optiontelescopic rail, full extraction, telescopic rail, partial extraction Only for loose deliveries1-hand-mounting lower costs option No mounting in Racks possibleconsisting of consisting of max. 1x per system- 1 pair of telescopic rails - 1 pair of telescopic railswith easy-mounting-clips with partial extraction1x per system 1x per systemS26361-F2735-E8CCabel arm for 1U Server- for FSC Primecenter / S26361-F2735-L101Datacenter Racks S26361-F2735-L110- for 3rd Party racks RMK_1U Server1x per system for loose deliverypartial extraction is lower costversion of RMK. Server could notcompletly pulled out of the Rack<strong>PRIMERGY</strong> PRIMECENTER-rack In case nor cable arm is ordered,S26361-F1647-E302Installation ex works for oneServer must be prevent of beeingpulledout.S26361-F2735-L8server or subsystem. Cabel arm for 1U ServerHereby the rack will be delivered for loose deliverycompletely pre-mounted andall wired connections are tested.S26361-F2735-L7With racks 12U, 24U, 38U: Cable management PC-RackSystems and components - for FSC Primecenterwill be delivered installed in the rack - one additional U is neededWith racks 46U: for cable routing at the sideSystems and componentswill be delivered separately <strong>PRIMERGY</strong> 42/23U rackTo be ordered only together with <strong>PRIMERGY</strong> Classic 19" rack is not supporteda <strong>PRIMERGY</strong> PRIMECENTER racke . g . : "Rack-mounting ex factory"S26361-K826-V10xrefer configurator PC-RackThis service is to be ordered onceper installable server/storagemax. 1x per System subsystem, in order to get theserver/storage subsystemmounted into the <strong>PRIMERGY</strong> racks.In case of the 46 U <strong>PRIMERGY</strong> Rack,this service has to be ordered,to get the mounting kits and thecables installed.CFujitsu Technology Solutions x86 <strong>PRIMERGY</strong> Server 8 of 20

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!