PRIMERGY RX200 S4 - Nettailer
PRIMERGY RX200 S4 - Nettailer
PRIMERGY RX200 S4 - Nettailer
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
System configurator and order-information guideB <strong>PRIMERGY</strong> <strong>RX200</strong> <strong>S4</strong> Status 2009-05-28Base unit without CPU and Memory S26361-K1167-V101Rack version for 19'' racks with1 hot plug power supply moduleNo Rack-mounting kit includedFor an orderable basic unit one CPU = first CPU,one memory = first memory as well as one of twopossible rack-mount kit options has to be selectedS26113-F527-E12nd redundant PSU module For later conversion the following kit is available:for redundancy 1.) 1 power supply module hot plug S26113-F527-L1uses hot plug PSU slot incl. power cordmax. 1x per systemS26361-F2735-E101 S26361-F2735-E110 S26361-F2735-E111RMK-F1_1-2U Server RMK-P_1-2U Server No Rackmount-Kit optiontelescopic rail, full extraction, telescopic rail, partial extraction Only for loose deliveries1-hand-mounting lower costs option No mounting in Racks possibleconsisting of consisting of max. 1x per system- 1 pair of telescopic rails - 1 pair of telescopic railswith easy-mounting-clips with partial extraction1x per system 1x per systemS26361-F2735-E8CCabel arm for 1U Server- for FSC Primecenter / S26361-F2735-L101Datacenter Racks S26361-F2735-L110- for 3rd Party racks RMK_1U Server1x per system for loose deliverypartial extraction is lower costversion of RMK. Server could notcompletly pulled out of the Rack<strong>PRIMERGY</strong> PRIMECENTER-rack In case nor cable arm is ordered,S26361-F1647-E302Installation ex works for oneServer must be prevent of beeingpulledout.S26361-F2735-L8server or subsystem. Cabel arm for 1U ServerHereby the rack will be delivered for loose deliverycompletely pre-mounted andall wired connections are tested.S26361-F2735-L7With racks 12U, 24U, 38U: Cable management PC-RackSystems and components - for FSC Primecenterwill be delivered installed in the rack - one additional U is neededWith racks 46U: for cable routing at the sideSystems and componentswill be delivered separately <strong>PRIMERGY</strong> 42/23U rackTo be ordered only together with <strong>PRIMERGY</strong> Classic 19" rack is not supporteda <strong>PRIMERGY</strong> PRIMECENTER racke . g . : "Rack-mounting ex factory"S26361-K826-V10xrefer configurator PC-RackThis service is to be ordered onceper installable server/storagemax. 1x per System subsystem, in order to get theserver/storage subsystemmounted into the <strong>PRIMERGY</strong> racks.In case of the 46 U <strong>PRIMERGY</strong> Rack,this service has to be ordered,to get the mounting kits and thecables installed.CFujitsu Technology Solutions x86 <strong>PRIMERGY</strong> Server 8 of 20