Emergency lighting units<strong>EM</strong> <strong>powerLED</strong>Standards• according to EN 50172• according to EN 60598-2-22• EN 61347-2-7• EN 61347-2-13• EN 62384• EN 62034• EN 55015• EN 61000-3-2• EN 61000-3-3• EN 61547• EN 60068-2-64• EN 60068-2-29• EN 60068-2-30• EN 62386 (according to DALI standard V1)Duration link selectionDuration1 hrLink Positionwithout jumperTechnical data batteriesAccu-NiCdCase temperature rangeto ensure 4 years design life4.2 / 4.5 Ah D +5 °C to +55 °CBattery voltage/cell1.2 VCapacity D4.2 / 4.5 AhMax. short term temperature (reduced life-time) 70 °CMax. number discharge cyclesPacking quantity4 cycles per year plus4 cycles duringcomissioning5 pcs. per cartonAccu-NiMhCase temperature rangeto ensure 4 years design life2.0 Ah Cs +5 °C to +55 °C4.0 Ah Cs +5 °C to +50 °CBattery voltage1.2 VCapacity2.0 Ah / 4.0 AhMax. short term temperature (reduced life-time) 70 °CMax. number discharge cyclesPacking quantity4 cycles per year plus4 cycles duringcomissioning5 pcs. per carton2 hr3 hrposition Aposition BJumper selectionModule supplied with jumper in 3 hours position (position B).The position of the link will only be read on first power up. If it is changed afterwardsboth the battery and mains supply must be disconnected for 10 secondsto enable the <strong>EM</strong> <strong>powerLED</strong> <strong>EZ</strong>-3 to read the new link position on reconnectionof the battery and mains. It will lead to a false battery failure indication if the linkis changed after installation without this reset.Further technical dataThe <strong>EM</strong> <strong>powerLED</strong> has a unique power regulation circuit; this is designed to limitthe total power drawn from the battery in the event of using LED’s with a forwardvoltage (Vf) higher than 3.4 V.In such cases the unit will reduce the LED current in order to maintain anacceptable drain current from the battery and hence meet the required durationtime. This feature enables the <strong>EM</strong> <strong>powerLED</strong> <strong>PRO</strong> <strong>EZ</strong>-3 to have minimum batterycount for a given range of LED’s.Storage• Batteries should be stored within the specified temperature range inlow humidity conditions. Optimal storage conditions are– temperature: +5 °C to +25 °C– humidity: 65 % ±20 %• Avoid atmosphere with corrosive gas• It is recommended to disconnect the battery before store or delivery• Avoid to store the batteries discharged• A long term storage in open circuit leads to battery self discharge anddeactivation of chemical components. It could be required to charge and dischargethe batteries a few times to recover the initial performance.BatteriesConnection method: 4.8 x 0.5 mm spade tag welded to end of cellFor stick packs this connection is accessible after the battery caps have beenfitted.To inhibit inverter operation disconnect the batteries by removing the connectorfrom the battery spade tag.For battery data see separate data sheet.Data sheet 03/15-<strong>EM</strong>001-11Subject to change without notice.www.tridonic.com 6

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!