Practical examples of installation in the TD rangeThe TD-<strong>MIXVENT</strong> system offers the most versatile installation range on the market,as a result of its multiple combinations; it can be used in a large number of smalland mid-range ventilation installations.Domestic - Range Hood ExhaustOffice<strong>Industrial</strong> - Public RestroomSchool - Dining Hall<strong>Industrial</strong> - Locker RoomHealth - Waiting Room4


Exercise RoomCopy RoomComputer RoomLaboratoryHair SalonResidential Basement5


Supply/Exhaust for ducts TD-<strong>MIXVENT</strong>General details of theTD-<strong>MIXVENT</strong> rangeLow profile mixed flow fans, manufacturedin plastic material (up to model 200) or ingalvanized steel sheet protected with Epoxypaint (model 250 and 315), with external terminalbox, removable motor-impeller assembly andadjustable single-phase motor, Class B, IP44.Construction characteristics100 100x 125 150 200 250 315Polypropylene housing • • • • •Steel housing with epoxy coating • •ABS fan blades • • • • •Aluminum fan blades • •Thermal link via fuse•Thermal link with automatic reset • • • • • •Permanently lubricated ball bearings • • • • • • •Speed controllable 2-speed motor • • • • • • •The extensive range of the TD-<strong>MIXVENT</strong> series makes it an effective solution fora wide range of residential and light commercial ventilation installations.6


Supply/Exhaust for ducts TD-<strong>MIXVENT</strong>TD-<strong>MIXVENT</strong>Technical SpecificationsPerformance characteristicsAll models include a direct two speed motor connection.ModelTD-100TD-100xTD-125TD-150TD-200TD-250TD-315LS= Low SpeedHS = High SpeedNom.RPM Volts Max.CFM v Static Pressure (SP) Ins. WGWatts Speed 0” 0.125” 0.25” 0.375” 0.5” 0.75” 1.0”Max.SPMaxoperatingtemp. (ºF)2431 120 23 LS 97 81 51 - - - - .4 104 2 4”2516 120 26 HS 101 85 57 - - - - .4 104 2 4”1556 120 20 LS 100 77 48 - - - - .375 104 4.4 4”2096 120 33 HS 135 113 90 53 - - - .55 104 4.4 4”1633 120 24 LS 149 110 73 - - - - .35 104 4.4 5”2146 120 38 HS 197 168 133 86 22 - - .55 104 4.4 5”1709 120 54 LS 218 193 163 128 105 24 - .8 140 4.4 6”2289 120 65 HS 293 273 250 227 206 131 35 1.15 140 4.4 6”2322 120 139 LS 476 422 373 317 260 40 - 1.38 140 8.8 8”2781 120 184 HS 538 495 458 418 367 190 10 1.625 140 8.8 8”2400 115 162 LS 541 475 418 355 295 218 170 2.03 140 19.8 10”3200 115 241 HS 754 715 680 640 606 520 405 2.53 140 19.8 10”2000 115 208 LS 751 670 545 420 285 190 130 1.62 140 30.9 12.4”2500 115 335 HS 1050 990 932 850 770 600 420 2.95 140 30.9 12.4”Dimensions (inches/mm)Soler & Palau USA certifies thatthe TD range shown herein islicensed to bear the AMCA Seal.The ratings shown are based ontests and procedures performedin accordance with AMCA Publication211 and comply with therequirements of the AMCA CertifiedRatings Program.The TD-<strong>MIXVENT</strong> Models 100,100x and 150 are California Title 24compliant and meet ASHRAE 62.2when installed with a CVC and otherTD models are compliant wheninstalled with a 3 way switch andremotely mounted speed control.CWgt.(lbs)RU LDuctDia.Ins.U STD 250 & 315are UL listed foroutdoor use.Sound characteristicsFan sound levels are measured in sones. At this time there are no sone level test standards available through HVI due to the fact thatremote mounted fan noise levels are in proportion to the following: type of duct, length of duct, fan distance from the intake sourceand other miscellaneous factors. However, it is generally accepted that remote mounted venting is usually quieter than standard (inroom) venting.Model X A B C D E F G HTD-1005 15/16 1519 1/8 2325 7/16 1383 3/4 963 7/8 983 1/4 823 3/4 951 7/8 482 1/16 52TD-100x7 3/8 18811 15/16 3036 15/16 1764 1/2 1153 13/16 973 15/16 1003 9/16 903 1/8 802 3/8 60TD-1257 3/8 18810 3/16 2586 15/16 1764 1/2 1154 13/16 1233 15/16 1003 9/16 903 1/8 802 3/8 60TD-1508 3/8 21211 5/8 2957 7/8 20051275 13/16 1474 7/16 1125 1/8 1303 1/8 802 3/8 60TD-2009 3/16 23311 7/8 3028 9/16 2175 9/16 1417 13/16 1984 7/8 1245 1/2 1403 15/16 1003 11/16 94TD-25011 7/16 29115 3/16 38610 11/16 2727 9/16 1929 3/4 2486 1/8 1556 5/8 1685 11/16 1455 1/2 140TD-3151435617 11/16 45013 1/4 3368 13/16 22412 5/16 3127 3/8 1888 1/4 2107 3/16 18271788


<strong>TDx2</strong>-<strong>MIXVENT</strong>This system is designed for cases in which the fanoffers the appropriate flow but the pressure needs tobe increased due to complications in the duct.The <strong>TDx2</strong>-<strong>MIXVENT</strong> system is a standard catalogproduct from models 125 to 250. A <strong>TDx2</strong> can also beobtained by connecting 2 identical TD fans using anMBR flange (see accessories page).<strong>TDx2</strong>-<strong>MIXVENT</strong>Pressure increasePerformance CharacteristicsAll models include a direct two speed connection.Model<strong>TDx2</strong>-125<strong>TDx2</strong>-150<strong>TDx2</strong>-200<strong>TDx2</strong>-250LS= Low SpeedHS = High SpeedNom.RPM Volts Max.WattsDimensions (inches/mm)SpeedCFM v Static Pressure (SP) Ins. WG0” 0.25” 0.5” 0.75” 1” 1.5” 2.0” 2.25”Max.SPMaxoperatingtemp. (ºF)1651 120 88 LS 146 115 73 - - - - - .7 104 12 5”2125 120 118 HS 192 159 128 86 33 - - - 1.1 104 12 5”1924 120 108 LS 239 211 186 160 135 58 - - 1.6 140 11 6”2444 120 130 HS 312 292 271 249 224 154 60 - 2.3 140 11 6”2322 120 278 LS 399 377 356 338 322 288 247 163 2.76 140 19 8”2781 120 368 HS 479 460 442 425 408 374 341 300 3.25 140 19 8”1870 120 336 LS 543 488 440 389 333 250 208 164 3.7 140 41 10”2601 120 510 HS 765 729 689 655 621 500 344 275 4.7 140 41 10”Wgt.(lbs)DuctDia.Ins.Supply/Exhaust for ducts TD-<strong>MIXVENT</strong><strong>TDx2</strong>-<strong>MIXVENT</strong> X A B C D E F G H<strong>TDx2</strong>-1257 3/8 18816 7/164176 15/161764 1/8 1154 13/16 1233 15/16 1003 9/16 909 15/162532 1/8 60<strong>TDx2</strong>-1508 3/8 21218 1/44647 7/8 20051275 13/161474111.55 1/8 1309 13/162492 1/8 60<strong>TDx2</strong>-2009 1/8 23319 11/165008 9/16 2175 9/161417 13/16 1984 7/8 1245 1/2 14011 3/42983 11/16 94<strong>TDx2</strong>-25011 7/16 29125 3/5 65410 11/162727 9/16 1929 3/4 2486 1/8 1556 5/8 16816 3/84165 11/16 145Sound characteristicsFan sound levels are measured in sones. At this time there are no sone level test standards available through HVI dueto the fact that remote mounted fan noise levels are in proportion to the following: type of duct, length of duct, fan distancefrom the intake source and other miscellaneous factors. However, it is generally accepted that remote mountedventing is usually quieter than standard (in room) venting.9


<strong>MIXVENT</strong> FILTER System (TD-<strong>MIXVENT</strong> + MFL Filtering Box)This system is used when the characteristics of theinstallation require filtered external air to be introduced,to prevent the entry of dust and impurities to the areabeing ventilated. The <strong>MIXVENT</strong> FILTER system iscomposed of a standard TD-<strong>MIXVENT</strong> fan (from model100) coupled to a filtering box from the MFL series.The MFL filtering boxes are the Gravimetric EU3 type,which are capable of filtering between 80-95% ofparticles greater than 10 microns.Dimensions (inches/mm)Supply/Exhaust for ducts TD-<strong>MIXVENT</strong>The MFL filtering boxes have aneasy open cover, in order to quicklychange the filtering element.Type A B D E FMFL-100 7 7/8 200 7 7/8 200 3 15/16 100 6 1/16 154 7 11/16 196MFL-125 7 7/8 200 7 7/8 200 4 15/16 125 6 1/16 154 7 11/16 196MFL-150 8 11/16 220 8 11/16 220 6 5/16 160 6 1/16 154 7 11/16 196MFL-200 9 9/16 243 9 5/8 244 7 7/8 200 6 1/16 154 7 15/16 202MFL-250 11 9/16 293 11 7/8 294 9 13/16 250 6 1/16 154 8 1/8 206MFL-315 13 7/16 342 13 1/2 343 12 3/8 315 6 1/16 154 8 1/8 20610


TD-<strong>MIXVENT</strong> Assembly AccessoriesSpecific assembly accessories for the following seriesDimensions (inches/mm)MCABackdraft dampers are installedat the fans’ discharge. They preventthe entry of odors, air currentsand prevent heat leaks when theexhauster is not in operation. Forapplication to models in the TDand <strong>TDx2</strong>.MCA-100-315MCA-355-400Model A B C DMCA-1004 3/16 1074 3/8 1111 1/4 313 11/16 94ModelType TD and <strong>TDx2</strong>MCA-100 100MCA-125 125MCA-150 150MCA-200 200MCA-250 250MCA-315 315MARConnections for rectangularducts enable devices from the TDand <strong>TDx2</strong> series to be connectedto a rectangular duct.ModelTypeTD - <strong>TDx2</strong> - TDx3TWINMAR-100 100MAR-125 125MAR-150 150MAR-200 200MAR-250 250MAR-315 315MCA-125MCA-150MCA-200MCA-250MCA-3154 3/16 1074 3/4 1215 3/16 1316 3/16 1648 1/16 2055 3/8 1366 7/16 1638 7/16 21410 3/8 26413Dimensions (inches/mm)3301 1/4 311 3/8 351 3/8 351 5/8 421 15/16 504 11/16 1195 13/16 1477 3/4 1979 3/4 24812 5/16 312Nominal dim.of ducting L x H(in/mm)Model A B C E F G9 x 6224 x 14010MAR-1003/8 7 1/16 1 5/16 6 5/16 9 5/8 3/8264 180 33 160 244 99 x 6224 x 14010MAR-1253/8 7 1/16 1 5/16 6 5/16 9 5/8 3/8264 180 33 160 244 911 x 7280 x 18012MAR-1505/8 8 11/16 1 7/16 7 7/8 11 13/16 3/812 x 8 320 220 37 200 300 9315 x 20014 9MAR-2007/16 1 7/16 8 11/16 13 3/16 3/816 x 10 355 240 37 220 335 9400 x 2501720 x 12MAR-2505/16 11 7/16 1 5/8 10 5/8 16 9/16 3/8440 290 42 270 420 9500 x 315MAR-31521 1/4540143552 1/16 521435520 1/25203/89Supply/Exhaust for ducts TD-<strong>MIXVENT</strong>11


Bathroom Ventilation Concerns. . .Solved!If the strongest, quietest, bathroom exhaust system is what youseek…look no further. S&P offers the perfect solution with the mostoptions. The popular and exclusive TD series Bathroom exhaust kits(for single or dual venting points). All S&P Bath kits offer remotelymounted fans featuring a powerful motor mounted in the attic (awayfrom the living space). The result is a “Turbo” powered fan (muchstronger than generally associated with bathroom exhaust) and yeta peacefully quiet operation.KIT Bathroom Exhaust KitsThe Exhaust Kits in the <strong>MIXVENT</strong> series are sets of fans and accessories prepared forventilation installations in small enclosures, especially bathrooms and toilets. All TD Kitshave standard 7-year warranty.TD Standard Exhaust KitsKIT-TD100• 1 TD100 exhaust fan• 1 Plastic round grill PG-100• 1 Exterior louvered shutterKIT-TD100x• 1 TD100x exhaust fan• 1 Plastic round grill PG-100• 1 Exterior louvered shutterKIT-TD150• 1 TD150 exhaust fan• 1 Plastic round grill PG-150• 1 Exterior louvered shutterTD Deluxe Exhaust KitsKIT-TD150-DV• 1 TD150 exhaust fan• 2 Plastic round grills (BOR-150)• 1 Y-fitting (SY-6)• 7 Nylon tie wraps (TW-6)• 1 Integral mounting bracket* IMPORTANTIf venting in non-insulated attic space or in acold climate, insulated flexible duct work isrecommended to avoid condensation issues.Supply/Exhaust for ducts TD-<strong>MIXVENT</strong>13


Additional general assembly accessoriesBOR/BOCRound plastic/metaladjustable grillPGRound grill without built-inbackdraft damperPGDRound grill with built-inbackdraft damperMBRConnection FlangesSupply/Exhaust for ducts TD-<strong>MIXVENT</strong>PER-WPlastic louver shutterSRReducerPERHigh pressure aluminumlouver shutterSYY sheet metal adapterGRAAluminum exteriorfixed grillsMFLFiltering BoxIDFlexible round ductElectrical accessoriesEPBTElectronic push button timerSCSSpeed control slide typeSCSpeed control14


TH-<strong>MIXVENT</strong> SeriesRoof Mounted <strong>Fans</strong>S&P is introducing the TH-<strong>MIXVENT</strong> roof top series powered by the TD-<strong>MIXVENT</strong> fan. The TH-<strong>MIXVENT</strong> fans are supplied for exhaustingair; however, the motor and impeller housing can be removed andturned 180º to provide supply air ventilation. All modelsincorporate standard single phase two speed motors.Designed for direct connection to round ducting.Dimensions (inches/mm)<strong>Fans</strong>sforfLife!Model A B C D E F G H ITH-250 21 1/2 18 17 1/8 9 3/4 13 1/2 13/16 14 5/8 1 5/8546 457 435 248 330 12 20 372 4215/1628 21TH-315 7/16 22 1/16 12 5/16 17 11/16 1/2 13/16 17 11/16 1 15/16735 544 560 312 450 12 20 450 50CThe TH-<strong>MIXVENT</strong> SeriesRU Lfans are California TitleU S 24 compliant and meetASHRAE 62.2 when installedwith 3 way switch andremotely mounted speedcontrol.New Product TH-<strong>MIXVENT</strong>Performance characteristicsModel RPMCFM v Static Pressure (SP) Ins. WG0” 0.125” 0.25” 0.375” 0.5” 0.75” 1” 1.25”TH-2502000 431 385 336 285 240 192 157 1272600 605 592 574 510 482 393 318 261TH-3151500 603 522 421 363 260 165 98 432200 824 757 698 643 581 423 318 24215


Soler & Palau USA6393 Powers Ave.Jacksonville, FL 32217800.961.7370800.961.7379www.solerpalau-usa.comSoler & Palau Canada61 A Baywood roadToronto, ON M9V 3Y8866.733.0233866.358.5346www.solerpalaucanada.com