12.07.2015 Views

Scapula Plates, Acumed - ShoulderDoc.co.uk

Scapula Plates, Acumed - ShoulderDoc.co.uk

Scapula Plates, Acumed - ShoulderDoc.co.uk

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

LoCKING SCAPULAPLATE SYSTEMSince 1988 <strong>Acumed</strong> has beendesigning solutions to thedemanding situations facingorthopaedic surgeons, hospitalsand their patients. Ourstrategy has been to know theindication, design a solution tofit and deliver quality productsand instruments.The scapula plays an importantfunctional role by linking the upperextremity and the axial skeletonthrough its articulation of thesternoclavicular joint, the acromioclavicularjoint and the glenoid.<strong>Acumed</strong>’s Locking <strong>Scapula</strong> <strong>Plates</strong>are designed to provide excellentfixation for acute fractures,malunions and non-unions of thescapula.While often treated <strong>co</strong>nservatively,a portion of these displacedfractures can benefit from a lowprofile,<strong>co</strong>ngruent locking plate.Minimized soft tissue irritation aidswith patient rehabilitation and anearlier return to function.Indications<strong>Scapula</strong>r Body FracturesGlenoid Neck FracturesIntra-articular Glenoid Fractures<strong>Scapula</strong> Spine FracturesAcromial FracturesOs AcromialeBack support with locking technology.Fractures of the scapula are rare. The relative rarity of the moreseverely displaced injuries makes internal fixation of scapula fracturestechnically challenging. Anatomic <strong>co</strong>nstraints, particularly thescapula’s limited osseous anatomy, curved posterior surface andunique dimensions have <strong>co</strong>ntributed to the <strong>co</strong>mplexity of traditionaloperative treatment methods.With the introduction of the Locking <strong>Scapula</strong> Plate System,<strong>Acumed</strong> has taken locking technology one step further. Thedevelopment of these innovative implants improves the ability torestore functional normalcy to patients who have sustained displacedscapular fractures.Designed in <strong>co</strong>njunction with William B. Geissler M.D., <strong>Acumed</strong>’sindication-specific plates allow surgeons to choose a <strong>co</strong>nstructbased on their patients’ needs. The pre-<strong>co</strong>ntoured design eliminatesthe need to bend the plates to match the patient’s anatomyand better restores the functional angle of the shoulder joint. Thisdesign not only reduces OR time spent <strong>co</strong>ntouring a plate, butalso minimizes soft tissue irritation for the patient. The pre-<strong>co</strong>ntouredplates also help the surgeon reduce the fracture by actingas templates.2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!