12.07.2015 Views

PowerFlex 400 Adjustable Frequency AC Drive ! ! !

PowerFlex 400 Adjustable Frequency AC Drive ! ! !

PowerFlex 400 Adjustable Frequency AC Drive ! ! !

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

English-2<strong>PowerFlex</strong> <strong>400</strong> <strong>Adjustable</strong> <strong>Frequency</strong> <strong>AC</strong> <strong>Drive</strong> Quick Start!!ATTENTION: An incorrectly applied or installed drive can result incomponent damage or a reduction in product life. Wiring or applicationerrors, such as, undersizing the motor, incorrect or inadequate <strong>AC</strong>supply, or excessive ambient temperatures may result in malfunction ofthe system.ATTENTION: The bus regulator function is extremely useful forpreventing nuisance overvoltage faults resulting from aggressivedecelerations, overhauling loads, and eccentric loads. However, it canalso cause either of the following two conditions to occur.1. Fast positive changes in input voltage or imbalanced input voltagescan cause uncommanded positive speed changes;2. Actual deceleration times can be longer than commandeddeceleration timesHowever, a “Stall Fault” is generated if the drive remains in this statefor 1 minute. If this condition is unacceptable, the bus regulator must bedisabled (see parameter A187).Mounting Considerations• Mount the drive upright on a flat, vertical and level surface.Frame Screw Size Screw TorqueC M5 (#10-24) 2.45-2.94 N-m (22-26 lb.-in.)D M8 (5/16 in.) 6.0-7.4 N-m (53.2-65.0 lb.-in.)E M8 (5/16 in.) 8.8-10.8 N-m (78.0-95.3 lb.-in.)F M10 (3/8 in.) 19.6-23.5 N-m (173.6-208.3 lb.-in.)• Protect the cooling fan by avoiding dust or metallic particles.• Do not expose to a corrosive atmosphere.• Protect from moisture and direct sunlight.Maximum Surrounding Air TemperatureFrame Enclosure Rating Temperature Range Minimum MountingClearancesC IP 20/UL Open-Type -10° to 45°C (14° to 113°F) Figure 1: Option AIP 30/NEMA 1/UL Type 1 (1) -10° to 45°C (14° to 113°F) Figure 1: Option BIP 20/UL Open-Type -10° to 50°C (14° to 122°F) Figure 1: Option BD, E, F IP 30/NEMA 1/UL Type 1 -10° to 45°C (14° to 113°F) Figure 2:(1)Frame C drives require installation of the <strong>PowerFlex</strong> <strong>400</strong> IP 30/NEMA 1/UL Type 1option kit to achieve this rating.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!