In case of heating at the cooling mode or cooling at the heating mode(cont.)From the previous pageDoes theEEV operatenormally?NoIs much frostin the heat exchanger?NoConnect the connector.YesCheck theresistance value of EEV coil.NGEEV coil errorOKYesIs much frostin the heat exchanger?NoExchangethe out PCB.YesEEV main body errorDoesthe outdoor fanoperate at the operation ofcompressor?YesThe over shortage of refrigerant, InsufficientCapacity, Load estimation errorNoIs theoutdoor fan connectedcorrectly?NoConnect the connector.YesCheck the resistance valueof outdoor fan.NGOutdoor fan errorOKDose thevoltage of DC300Vapply to the connector of outdoorfan during the operation ofoutdoor unit?YesCheck the motor wire.NoOutdoor PCB error4-22 Samsung ElectronicsCH£ª£ª£ªCAV_USA_30520_SM_N.indd 22 2009-2-18 17:33:44