216GigaLine ® Fiber optic patch cord, MTPType KL-I-F(ZN)H/KL-I-F(ZN)HHMTP/MPO patch cordGigaLine® Patch MTP I-F(ZN)H 1x12GigaLine® Patch MTP I-F(ZN)HH 2x12DescriptionConnection-ready MTP patch cord – assembledat both ends with one or two MTP plugs (female) or one MTP(female) to six LC Duplex Uniboot plugs.ConstructionCable typeStrain reliefCable sheathColour of sheathCable diameterField of application■■■■■■■■KL-I-F(ZN)H 1x1 orKL-I-F(ZN)HH 2x12AramidHalogen-free, flame-retardant compoundOM3 ● Aqua | OM4 ● Heather violet3.0 mm (for 1x12)8.9 mm (for 2x12)In DataCenters as a patch cord for applications acc. toISO/IEC 11801 and EN 50173 (2nd edition)GigaLine® Patch MTP–6LCDU (fanout) for multimodeapplications via two fibers (up to 10GBASE-SR)GigaLine® Patch 1MTP–1MTP for multimode applicationsvia 2 x 4 fibers (40GBASE-SR4)GigaLine Patch 2MTP–2MTP for multimode applicationsvia 2 x 10 fibers (100GBASE-SR10)Thermal characteristicsTransport/storage –25 °C up to +70 °CInstallation–5 °C up to +50 °COperating temp. –10 °C up to +70 °CMechanical characteristicsBending radiusKL-I-F(ZN)H 1x12 static 35 mm | dynamic 65 mmKL-I-F(ZN)HH 2x12 static 35 mm | dynamic 65 mmTensile strengthKL-I-F(ZN)H 1x12 300 NKL-I-F(ZN)HH 2x12 600 NOptical characteristics (typical)Insertion loss 0.3 dB (MTP) For all fiber typesReturn lossFire performanceFlame retardancyHalogen-freeSmoke density0.2 dB (LCDU) For all fiber typesOM3/OM4OM3/OM4> 20 dB (MTP)> 40 dB (LCDU)IEC 60332-1/IEC 60332-3-24IEC 60754-1IEC 61034Designation Equipment on side A Equipment on side B Order no.GigaLine® Patch 12 OM3 6 LC/DU–1 MTP* 6x LC/Dx-Uniboot OM3 MTP female 12 OM3 LKD 9R72 1002 0000GigaLine® Patch 12 OM4 6 LC/DU–1 MTP* 6x LC/Dx-Uniboot OM4 MTP female 12 OM4 LKD 9R72 4002 0000GigaLine® Patch 12 OM3 MTP–MTP* MTP female 12 OM3 MTP female 12 OM3 LKD 9R71 5xxx 0000GigaLine® Patch 12 OM4 MTP–MTP* MTP female 12 OM4 MTP female 12 OM4 LKD 9R71 3xxx 0000GigaLine® Patch 2x12 OM3 MTP–MTP* 2x MTP female 2x12 OM3 2x MTP female 2x 12 OM3 LKD 9R71 6xxx 0000GigaLine® Patch 2x12 OM4 MTP–MTP* 2x MTP female 2x12 OM4 2x MTP female 2x 12 OM4 LKD 9R71 4xxx 0000* Logically crossedxxx = Length in m. 1 piece per packing unit.www.leoni-infrastructure-datacom.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!