12.07.2015 Views

A 1 - Leoni

A 1 - Leoni

A 1 - Leoni

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

54MegaLine ® F10-130 S/F QH Type KS-02YSCHQH 4x2xAWG 22/1 PIMFCategory "7 A "S 3 P 4 I 4 C 5 E 5ConstructionConductor Bare copper wire, AWG 22/1InsulationTwisting elementIndividualshieldingTwistingOverall shieldingInner sheathArmourOuter sheathCellular-PE, core-diameter: nominal value 1.6 mmPairAluminium-bonded polyester foil, metal side outside(PiMF)4 pairsTinned copper braidingHalogen-free, flame-retardant compoundGalvanised steel wire braidingHalogen-free, flame-retardant compoundFire behaviourFlame retardancy acc. to IEC 60332-3-24Halogen free acc. to IEC 60754-1/2Smoke density acc. to IEC 61034-1/2Calorific value (approx.)1.53 MJ/mSecurity (fire behaviour)S1IEC 60332-2-22IEC 60332-1-23IEC 60332-3-244EFPGrade 15EFPGrade 2PerformanceBetter than Category 7 acc. to EN 50288 and IEC 61156excellent NEXT, low attenuation,excellent shielding characteristics (shielding of pairs and overall shielding),low skew, bandwidth 1,300 MHzPerformance (cabling class, bandwidth)P 1> Class E> 250 MHz2> Class E A> 500 MHz3> Class F> 600 MHz4> Class F A> 1000 MHz5> Class "G"> 1200 MHzApplicationsInstallation cable for use in structured cabling systems acc. to ISO/IEC 11801and EN 50173 (2nd edition) as well as ISO/IEC 24702 and EN 50173-3. Ideal forall applications from Classes D to F A Multimedia (video, data, voice) >10 GbEacc. to IEEE 802.3 an, cable sharing, VoIP, PoE.For use indoors and outdoors (with reservations) and in harsh environments.With rodent protection.Industrial application (Ethernet, TV)I1> 100 MbE2> 1 GbE3Up to 10GbE4> 10 GbE5> 10 GbETVMechanical characteristicsBending radius during installation 8 x overall diameter (min.)after installation4 x overall diameter (min.)Tensile strength (max.)1,400 NCrush strength3,000 N/100 mmImpact strength (number of shocks) 50Construction (conductor dimensions, tensile strength)C 1AWG 272AWG 26/253AWG 244AWG 235AWG 22EMC (coupling attenuation)Electromagnetic behaviourTransfer impedance at 10 MHz (nominal value) 5 mΩ/m12Shielding attenuation up to 1,000 MHz (nominal value) 70 dBE > 40 dB > 50 dBCoupling attenuation up to 1,000 MHz (nominal value) 85 dB3> 60 dB4> 70 dB5> 80 dBwww.leoni-infrastructure-datacom.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!