Danger!Dangerous electrical voltage!Before commencing the installation• Disconnect the power supply of the device.• Ensure that devices cannot be accidentally restarted.• Verify isolation from the supply.• Earth and short circuit the device.• Cover or enclose any adjacent live components.• Follow the engineering instructions (IL04020001E) for thedevice concerned.• Only suitably qualified personnel in accordance withEN 50110-1/-2 (VDE 0105 Part 100) may work on thisdevice/system.• Before installation and before touching the device ensurethat you are free of electrostatic charge.• The functional earth (FE, PES) must be connected to theprotective earth (PE) or the potential equalisation. The systeminstaller is responsible for implementing this connection.• Connecting cables and signal lines should be installed sothat inductive or capacitive interference does not impair theautomation functions.• Install automation devices and related operating elements insuch a way that they are well protected against unintentionaloperation.• Suitable safety hardware and software measures should beimplemented for the I/O interface so that an open circuit on thesignal side does not result in undefined states in theautomation devices.• Ensure a reliable electrical isolation of the extra-low voltage ofthe 24 V supply. Only use power supply units complying withIEC 60364-4-41 (VDE 0100 Part 410) or HD384.4.41 S2.• Deviations of the mains voltage from the rated value mustnot exceed the tolerance limits given in the specifications,otherwise this may cause malfunction and dangerousoperation.• Emergency stop devices complying with IEC/EN 60204-1 mustbe effective in all operating modes of the automation devices.Unlatching the emergency-stop devices must not cause arestart.• Devices that are designed for mounting in housings or controlcabinets must only be operated and controlled after they havebeen installed and with the housing closed. Desktop orportable units must only be operated and controlled inenclosed housings.• Measures should be taken to ensure the proper restart ofprograms interrupted after a voltage dip or failure. This shouldnot cause dangerous operating states even for a short time.If necessary, emergency-stop devices should be implemented.• Wherever faults in the automation system may cause injury ormaterial damage, external measures must be implemented toensure a safe operating state in the event of a fault ormalfunction (for example, by means of separate limit switches,mechanical interlocks etc.).• Depending on their degree of protection, adjustable frequencydrives may contain live bright metal parts, moving or rotatingcomponents or hot surfaces during and immediately afteroperation.• Removal of the required covers, improper installation orincorrect operation of motor or adjustable frequency drive maycause the failure of the device and may lead to serious injury ordamage.• The applicable national accident prevention and safetyregulations apply to all work carried on live adjustablefrequency drives.• The electrical installation must be carried out in accordancewith the relevant regulations (e. g. with regard to cable crosssections, fuses, PE).• Transport, installation, commissioning and maintenance workmust be carried out only by qualified personnel (IEC 60364,HD 384 and national occupational safety regulations).• Installations containing adjustable frequency drives must beprovided with additional monitoring and protective devices inaccordance with the applicable safety regulations.Modifications to the adjustable frequency drives using theoperating software are permitted.Eaton Corp.Safety instructionsI

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!