Installation04/10 MN04020001Z-ENFunction of the control signal terminalsThe functions that are set in the ex-factory and the electricalconnection data of all control signal terminals are listed in thefollowing table.Table 4:Factory-set functions of the control terminalsTerminal Signal Factory setting Description1 +10V Output nominal voltage - <strong>Max</strong>imum load 10 mA, reference potential GND2 AI1 Analog signal input 1 <strong>Frequency</strong> reference value 1) 0 - +10 V (R i > 200 kO)0/4 - 20 mA (R B = 200 O)Selectable through microswitch S23 GND Reference potential - 0V4 AI2 Analog input 2 PID controller, actual value 1) 0 - +10 V (R i > 200 kO)0/4 - 20 mA (R B = 200 O)Selectable through microswitch S35 GND Reference potential - 0V6 24V Control voltage for DI1 - DI6,output (+24 V)7 DI-C Reference potential of thedigital inputs DI1 - DI6- <strong>Max</strong>imum load 50 mA, reference potential GNDLOGIC- (GND) Selectable through microswitch LOGIC –/+8 DI1 Digital input 1 FWD start enable, forward 1) 0 - +30 V (R i > 12 kO)9 DI2 Digital input 2 REV start enable, reverse 1) 0 - +30 V (R i > 12 kO)10 DI3 Digital input 3 Fixed frequency B0 1) 0 - +30 V (R i > 12 kO)13 DO- Digital output Active = READY 1) Transistor, max. 50 mA, supply voltage controlsignal terminal 2014 DI4 Digital input 4 Fixed frequency B1 1) 0 - +30 V (R i = 12 kO)15 DI5 Digital input 5 Error acknowledgment 1) 0 - +30 V (R i = 12 kO)16 DI6 Digital input 6 PI controller deactivated 1) 0 - +30 V (R i = 12 kO)18 AO Analog output Output frequency 1) 0 - +10 V, max. 10 mA20 DO+ Digital output Supply voltage, see controlsignal terminal 13Supply voltage for digital output DO max.48 V DC, max. 50 mA22 R13 Relay 1, normally open contact Active = RUN 1) <strong>Max</strong>imum switching load:250 V AC/2 A or 250 V DC/0.4 A23 R14 Relay 1, normally open contact Active = RUN 1) <strong>Max</strong>imum switching load:250 V AC/2 A or 250 V DC/0.4 A24 R22 Relay 2, changeover contact(N/C)Active = FAULT 1)<strong>Max</strong>imum switching load:250 V AC/2 A or 250 V DC/0.4 A25 R21 Relay 2, changeover contact Active = FAULT 1) <strong>Max</strong>imum switching load:250 V AC/2 A or 250 V DC/0.4 A26 R24 Relay 2, changeover contact(N/O)Active = FAULT 1)A A RS485 signal A BUS-Communication Modbus RTUB B RS485 signal B BUS-Communication Modbus RTU1) Programmable function (a section “List of parameters”, page 176)<strong>Max</strong>imum switching load:250 V AC/2 A or 250 V DC/0.4 A44

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!