IIIT DELHI,3 RD FLOOR, LIBRARY BUILDING,NSIT CAMPUS, SECTOR-3,DWARKA, NEW DELHI-110078NOTICE INVITING QUOTATION (SHORT TERM)<str<strong>on</strong>g>Sealed</str<strong>on</strong>g> <str<strong>on</strong>g>item</str<strong>on</strong>g> <str<strong>on</strong>g>rate</str<strong>on</strong>g> <str<strong>on</strong>g>quotati<strong>on</strong>s</str<strong>on</strong>g> <str<strong>on</strong>g>are</str<strong>on</strong>g> <str<strong>on</strong>g>invited</str<strong>on</strong>g> <str<strong>on</strong>g>for</str<strong>on</strong>g> <str<strong>on</strong>g>the</str<strong>on</strong>g> <str<strong>on</strong>g>following</str<strong>on</strong>g> <str<strong>on</strong>g>work</str<strong>on</strong>g> <strong>on</strong> behalf of Board of Governors,IIIT-D from <str<strong>on</strong>g>the</str<strong>on</strong>g> approved and eligible c<strong>on</strong>tractors of specialized job having <str<strong>on</strong>g>the</str<strong>on</strong>g> experience of SITC ofHybrid Type Evaporative cooling system <str<strong>on</strong>g>for</str<strong>on</strong>g> <str<strong>on</strong>g>the</str<strong>on</strong>g> <str<strong>on</strong>g>following</str<strong>on</strong>g> <str<strong>on</strong>g>work</str<strong>on</strong>g> so as to reach <str<strong>on</strong>g>the</str<strong>on</strong>g> office of undersignedup to 3.00 P.M. <strong>on</strong> 02-06-2009. Quotati<strong>on</strong>s shall be opened <strong>on</strong> <str<strong>on</strong>g>the</str<strong>on</strong>g> same day at 3.30 P.M. in Room No.301, Admn. Block, NSIT, Sector-3, Dwarka, New Delhi-110078 by <str<strong>on</strong>g>the</str<strong>on</strong>g> Executive Engineer (C)/IIIT-D.Name of <str<strong>on</strong>g>work</str<strong>on</strong>g>: Provisi<strong>on</strong> of Evaporative Cooling System in <strong>on</strong>e class and lab at IIITD transit campus<str<strong>on</strong>g>for</str<strong>on</strong>g> trial of <str<strong>on</strong>g>the</str<strong>on</strong>g> higher efficiency cooling system at <str<strong>on</strong>g>the</str<strong>on</strong>g> present campus.Estimated Cost: Rs. 2,34,416.00TERMS & CONDITIONS:-1 The <str<strong>on</strong>g>work</str<strong>on</strong>g> shall be carried out as CPWD Specificati<strong>on</strong>s <str<strong>on</strong>g>for</str<strong>on</strong>g> Electrical Work (Internal/External - `1994& 1995’).2 Any damage d<strong>on</strong>e to <str<strong>on</strong>g>the</str<strong>on</strong>g> equipment / building during executi<strong>on</strong> of <str<strong>on</strong>g>work</str<strong>on</strong>g> shall be <strong>on</strong> <str<strong>on</strong>g>the</str<strong>on</strong>g> part ofc<strong>on</strong>tractor.3 No T & P shall be issued to <str<strong>on</strong>g>the</str<strong>on</strong>g> C<strong>on</strong>tractor.4 The C<strong>on</strong>tractor must possess valid DVAT Certificate.5 The C<strong>on</strong>tractor must possess valid TIN No.6 Time allowed: 15 Days.7 Schedule of Quantity: As per Annexure-‘A’.8 Clause-12 of G.C.C. is applicable <str<strong>on</strong>g>for</str<strong>on</strong>g> E.I./S.I./Deviati<strong>on</strong> etc.9 EMD – Rs. 4,688.0010 Security Deposit @ 10% will be deducted from <str<strong>on</strong>g>the</str<strong>on</strong>g> bills of C<strong>on</strong>tractor.EXECUTIVE ENGINEER (C/M)/IIIT-D


PROJECT: IIIT Transit Campus (Third Floor, Library Building, NSIT, DWARKA)Annexure–ASUMMERY OF COST FOR HYBRID EVAPORATIVE COOLING WORKSS. No. Descripti<strong>on</strong> Unit Qty. Rate Amount1.0 Supply, Fabricated, installati<strong>on</strong> and commissi<strong>on</strong>ing of Hybrid Type Evaporative Each 1cooling system. Hybrid Cool Air System, built <strong>on</strong> <str<strong>on</strong>g>the</str<strong>on</strong>g> twin c<strong>on</strong>cept of air compressi<strong>on</strong>and water vaporizati<strong>on</strong>, as per detailed Technical Specificati<strong>on</strong>s below:1. Double Effect Cooling System2. Air Discharge: 10600 CFM at 130 Pa3. Dust Protecti<strong>on</strong> inside cooled <str<strong>on</strong>g>are</str<strong>on</strong>g>a – through Positive Pressure of apx 12to 18 mm water.4. Power C<strong>on</strong>sumpti<strong>on</strong>: 1 KWH.5. Self Cleaning System <str<strong>on</strong>g>for</str<strong>on</strong>g> Membrances by PLC C<strong>on</strong>trol6. Size: 1 m X 1 m X 1 m.7. Apx Wt: 105 Kgs (max with water)8. Air Changes: 30 to 35 per hr.9. Area Cooled: apx 12000 to 15000 CFT10. Body: Stainless Steel in Steel grey colour11. Air inlet Mebrance: Maintenance free Polymer type membrance.12. Motor: Twin speed with rating of 1.0 Kw.13. Double alloy Axil flow.2.0 AIR DISTRIBUTION :2.1 Supply, Fabricati<strong>on</strong>, installati<strong>on</strong>, testing and commissi<strong>on</strong>ing of GSS sheet metalducting complete with hangers, supports and rubber gasket sealing as per <str<strong>on</strong>g>the</str<strong>on</strong>g>specificati<strong>on</strong> and approved drawing.24 gauge GSS ducting. Sq.M. 38.522.2 Supply and applicati<strong>on</strong> of 20 mm polystyrene <str<strong>on</strong>g>the</str<strong>on</strong>g>rmal insulati<strong>on</strong> of ducting as per Sq.M. 38.52<str<strong>on</strong>g>the</str<strong>on</strong>g> specificati<strong>on</strong>s and drawings.2.3 Supply, installati<strong>on</strong>, testing & commissi<strong>on</strong>ing of extruded aluminium c<strong>on</strong>structedsupply air grille without volume c<strong>on</strong>trol Damper.Sq.M. 0.72EXECUTIVE ENGINEER (C/M)/IIIT-D

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!