www.thk.ru thk-mail@ya.ru Тел. (495) 727-22-72 Unit: mm<strong>LM</strong> rail dimensions Basic load rating Static permissible moment [kN-m]* 6 MassWidthHeightPitchLength* 5CC0MAMBMC<strong>LM</strong> block<strong>LM</strong> railW1±0.05W215 18.520 19.523 25.0M112.515.518.0F606060✕✕4.5✕7.5✕5.36✕9.5✕8.57✕11✕9Max2500(1240)3000(1480)3000(2020)[kN]14.719.631.5[kN]16.523.436.41 block0.07920.13800.2580Doubleblocks0.4400.7231.4201 block0.04860.08470.1580Doubleblocks0.2740.4480.8841 block0.09620.18000.3300[kg]0.190.310.53[kg/m]1.22.12.7*4 Pilot holes for side nipples are not drilled through in order to prevent foreign material from entering the product.THK will mount grease nipples per your request. Therefore, do not use the side nipple pilot holes for purposes other than mountinga grease nipple.*5 The maximum length under “Length” indicates the standard maximum length of an <strong>LM</strong> rail. (See page 13.)*6 Static permissible moment: 1 block: static permissible moment value with 1 <strong>LM</strong> blockDouble blocks: static permissible moment value with 2 blocks closely contacting with each other