MPC-6000 Intelligent Fire Alarm Panel - Louisiana Fire Extinguisher ...

MPC-6000 Intelligent Fire Alarm Panel - Louisiana Fire Extinguisher ...

MPC-6000 Intelligent Fire Alarm Panel - Louisiana Fire Extinguisher ...

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

The 80-characterLCD display isused to displayevent data, includingalarms andtroubles, supervisoryidentificationof zone or device,and presentationof history. Themenus are controlledby a set offour membraneswitches commandingthecontrol processor.A back light isincluded to assure visibility in low light, but toconserve power, it is only activated during areported event.Minimum Control Unit ConfigurationA. <strong>Intelligent</strong> Signaling Line Circuit –The main termination board has addressableloop interface circuitry supporting one SLC loopDevices are polarity insensitive and can operateon untwisted, unshielded wire.B. Notification Appliance Circuits – The base panelhas four independent NACs. Each circuit can beselected to give continuous output, one of eightsounding patterns. NACs are style Z or Ycapable, without additional modules.C. Dry Contacts – Four programmable form “C”dry relay contacts are provided.D. Remote Annunciation – The <strong>MPC</strong>-<strong>6000</strong> panel willdrive up to 16 annunciators and 8 remoteprocessors on an RS-485 communication line.E. Power Supply – A 7A, 24V nominal powersupply provides all operating power to the panelfor both standby and alarm conditions.Auxiliary DevicesA. Remote LCD Annunciator (RDC-2) – Theremote LCD annunciator consists of a backlit80 character, alphanumeric display, 4 menubuttons, 4 dedicated buttons for operatorinteraction, 6 LED indicators, and a securitykey switch.B. Serial Annunciator (SLU-2) – Consists of oneremote processor and one annunciator driverboard capable of providing 16 supervisedoutputs for LEDs or incandescent lamps.Expansion to drive 512 LEDs or lamps is viaadditional processor boards and annunciatordrive boards (SLE-16).C. Serial Relay Unit (SRU-2) – Consists of remoteprocessor and relay board which provides 8relays with form “C” dry contacts rated at 1 amp.Expansion to 192 relays is via additional remoteprocessor boards and relay boards (SLE-8).Optional Control Unit ConfigurationA. <strong>MPC</strong>-DACT – The <strong>MPC</strong>-DACT providesa dual line digital alarm communicationstransmitter. It’s parameters are set via thecontrol unit programming sequence.The <strong>MPC</strong>-DACT is compatible with the followingformats: SIA DCS 8, SIA DCS 20, AdemcoContact ID, 3/1 1400 Hz., 3/1 2300 Hz.,

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!