MODELS170-F/SPC-170HEATER SPECIFICATIONSType of Gas:For use with Propane OnlyGas Supply Pressureto regulator Maximum: Bottle Pressure Minimum: 5 psig (34.5 kPa)regulator out28" WC (6.97 kPa)Electrical Input:115V, 60 Hz, 1Ø, 3aIgnition:Direct Spark, interrupted typePrimary Flame Control:Solid State, 10-15 Second TimingHigh Temperature Control: 240°F (116°C) Minimum Ambient Temp. Rating: 0°F (-17.8°C)Model:Rating:Fuel Consumption:170-F/SPC-170125,000 - 170,000 BTU/hr(36.6 - 49.8 kW)5.8 - 7.9 lbs/hr(2.6 - 3.6 kg/hr))Fuel Orifice Port No.: 18Fuel Orifice Port Size:0.80mmHeated Air Output: 450 CFM (12.74 cu m/m)WARNINGSYOUR SAFETY IS IMPORTANT TO YOU AND TO OTHERS, SO PLEASEREAD THESE INSTRUCTIONS BEFORE YOU OPERATE THIS HEATER.GENERAL HAZARD WARNING:FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN RESULT INDEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN,ASPHYXIATION, CARBON MONOXIDE POISONING, AND/OR ELECTRICAL SHOCK.ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER.IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL, LABELS, ETC. CONTACTTHE MANUFACTURER.WARNING: NOT FOR HOME OR RECREATIONAL VEHICLE USEWARNING: FIRE, BURN, INHALATION, AND EXPLOSION HAZARD. KEEP SOLID COMBUSTIBLES, SUCH ASBUILDING MATERIALS, PAPER OR CARDBOARD, A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDEDBY THE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNECOMBUSTIBLES, OR PRODUCTS SUCH AS GASOLINE, SOLVENTS, PAINT THINNER, DUST PARTICLES OR UNKNOWNCHEMICALS.Scheu Products Company, IncorporatedMail: P.O. Box 250, Upland, CA 91785Plant: 8855 Baker Ave., Rancho Cucamonga, CA 91730Telephone: 800-325-7057www.scheuco.comcustomerservice@scheuco.comANSI Z83.7/CGA 2.14-20008770September 2003Page -2-


ODOR FADE WARNINGWARNINGAsphyxiation Hazard• Do not use this heater for heating human living quarters.• Do not use in unventilated areas.• The flow of combustion and ventilation <strong>air</strong> must not beobstructed.• Proper ventilation <strong>air</strong> must be provided to support thecombustion <strong>air</strong> requirements of the heater being used.• Refer to the specification section of the heater’s <strong>manual</strong>,heater dataplate, or contact the Scheu Products Company todetermine combustion <strong>air</strong> ventilation requirements of theheater.• Lack of proper ventilation <strong>air</strong> will lead to impropercombustion.• Improper combustion can lead to carbon monoxidepoisoning leading to serious injury or death. Symptom ofcarbon monoxide poisoning can include headachesdizziness and difficulty in breathing.FUEL GAS ODORLP gas and natural gas have man-made odorants added specifically for detection of fuel gas leaks.If a gas leak occurs you should be able to smell the fuel gas. Since Propane (LP) is heavier than <strong>air</strong> you should smell for the gasodor low to the floor. ANY GAS ODOR IS YOUR SIGNAL TO GO INTO IMMEDIATE ACTION!• Do not take any action that could ignite the fuel gas. Do notoperate any electrical switches. Do not pull any powersupply or extension cords. Do not light matches or any othersource of flame. Do not use your telephone.• Get everyone out of the building and away from the areaimmediately.• Close all <strong>propane</strong> (LP) gas tank or cylinder fuel supplyvalves, or the main fuel supply valve located at the meter ifyou use natural gas.• Propane (LP) gas is heavier than <strong>air</strong> and may settle in lowareas. When you have reason to suspect a <strong>propane</strong> leak,keep out of all low areas.• Use your neighbor’s phone and call your fuel gas supplierand your fire department. Do not re-enter the building orarea.• Stay out of the building and away from the area untildeclared safe by the firefighters and your fuel gas supplier.• FINALLY, let the fuel gas service person and the firefighterscheck for escaped gas. Have them <strong>air</strong> out the building andarea before you return. Properly trained service people mustrep<strong>air</strong> any leaks, check for further leakages, and then relightthe appliance for you.ODOR FADING - NO ODOR DETECTED• Some people cannot smell well. Some people cannot smellthe odor of the man-made chemical added to <strong>propane</strong> (LP)or natural gas. You must determine if you can smell theodorant in these fuel gases.• Learn to recognize the odor of <strong>propane</strong> (LP) gas and naturalgas. Local <strong>propane</strong> (LP) gas dealers will be more thanhappy to give you a scratch and sniff pamphlet. Use it tobecome familiar with the fuel gas odor.• Smoking can decrease your ability to smell. Being aroundan odor for a period of time can affect your sensitivity to thatparticular odor. Odors present in animal confinementbuildings can mask fuel gas odor.• The odorant in <strong>propane</strong> (LP) gas and natural gas iscolorless and the intensity of its odor can fade undersome circumstances.• If there is an underground leak, the movement of gasthrough the soil can filter the odorant.• Propane (LP) gas odor may differ in intensity at differentlevels. Since Propane (LP) gas is heavier than <strong>air</strong>, theremay be more odor at lower levels.• Always be sensitive to the slightest gas odor. If youcontinue to detect any gas odor, no matter how small, treat itas a serious leak. Immediately go into action as discussedpreviously.ATTENTION - CRITICAL POINTS TO REMEMBER!• Propane (LP) gas has a distinctive odor. Learn to recognizethese odors. (Reference Fuel Gas Odor and Odor Fadingsections above.• Even If you are not property trained in the service and rep<strong>air</strong>of the heater, ALWAYS be consciously aware of the odors of<strong>propane</strong> (LP) gas and natural gas.• If you have not been properly trained in rep<strong>air</strong> and service of<strong>propane</strong> (LP) gas then do not attempt to light heater,perform service or rep<strong>air</strong>s, or make any adjustments to theheater on the <strong>propane</strong> (LP) gas fuel system.• A periodic sniff test around the heater or at the heater’sjoints; i.e. hose, connections, etc., is a good safety practiceunder any conditions. If you smell even a small amount ofgas, CONTACT YOUR FUEL GAS SUPPLIER IMMEDIATELY.DO NOT WAIT!Page -4-


MODELS170-F/SPC-170SIZE AND CAPACITYOF PROPANE CYLINDERSThe charts below show the approximate size of the cylinderrequired for these <strong>heaters</strong>. To use the chart:1. Select the lowest <strong>air</strong> temperature expected (at thebottom of the chart).2. Move straight up to time of operation desired (left sideof the chart).3. Read the cylinder size required.All <strong>heaters</strong> should have:full cylindersgood <strong>air</strong> circulationno frost on cylindersTECHNICAL INFORMATIONHOW MUCH HEAT DO I REQUIRE?For economy, it is important to match input to thatrequired. But heat requirements often vary. For example,it usually takes a lot more heat to get things warm than itdoes to keep them that way. Likewise, outside <strong>air</strong> temperatureususally changes during the day so you may needmore heat at night than you do in the daytime. Anapproximation of the heat required can be found by usingthe chart below.BTU'S PER HOUR REQUIRED170-F/SPC-170Cubic feetTemperature Rise Required ( o F)*of space tobe heated 20 o 30 o 40 o 50 o5,000 14,000 20,000 27,999 34,0007,000 19,000 28,000 38,000 47,00010,000 27,000 40,000 54,000 67,00015,000 40,000 60,000 80,000 100,00020,000 54,000 80,000 107,000 133,00030.000 80,000 120,000 160,000 200,00050,000 133,000 200,000 266,000 333,000WARNING: When using a thermostat controled heater, itsexit area should be protected from personnel and warningsposted of sudden startup.Recommended Minimum Gauge for Cord ExtensionsWire Gauge Chart A.W.G.NamePlate 120VCord Length in FeetAmps. 25 50 100 1505-6 18 16 14 126-8 18 16 12 108-12 18 14 12 1010-12 16 14 10 812-14 16 12 10 8Page -6-


YYYWIRING DIAGRAMMODEL 170-F/SPC-170COLOR CODELEGENDB BLACKL BLUEG GREENO ORANGER REDW WHITETERMINAL BOARDY TERMINALMALE CONNFEMALE CONNIf any original wiring as supplied by the heater must be replaced, it must be replaced with type AWG 105° Cwire or its equivalent except as indicated (*type SF2-200, **SGI 250° C).WIRING CHARTPARTNO. COLOR LENGTH FROM TO1100 White 7" Valve Terminal Block1040 Black 6" On/Off Switch Terminal Block1226 Red (Hi-Temp) 16 1/2" High Limit Switch Valve1226 Red (Hi-Temp) 16 1/2" High Limit Switch Terminal Block1070 Orange 11" Flame Control (Ignition) Spark Plug1959 Green 7" Flame Control (Harness) Ground1959 Red 7" Flame Control (Harness) Terminal Block1959 White 6" Flame Control (Harness) Terminal Block1959 Black 6" Flame Control (Harness) Terminal BlockPage -7-


170-F/SPC-170 - PARTS87121632510922234111617181229272625192028303324131415343231IItem 170-F SPC-170 Description Qty. IItem 170-F SPC-170 Description Qty.1 2247 2248 Outer Shell 12 2249 2249 Middle Cylinder 13 2250 2250 Orifice Assembly 14 1146 1146 Flame Holder Assembly 15 6168 6168 High Limit Switch 16 3038 3038 Orifice Nut 17 7095 7095 Handle 18 7094 7094 Handle Mounting Clips 29 6010 6010 Set Screw, Nyloc 110 6074 6074 Fan 111 2251 2251 Motor Assembly 112 2252 2252 Grille, Inlet/Motor Mounting 113 6152 6152 Hose Assembly 114 6257 6257 Regulator, 28" WC 115 6433 6433 POL Excess Flow Valve 116 6122 6122 Male Fitting Conn. 3/8MPT x 3/8SAE FLR 117 6101 6101 Solenoid Valve, Goyen 118 8775 8775 Fitting Close Nipple 119 8777 8777 Burn Rate Adjustment Valve 120 8776 8776 Fitting, Elbow, 3/8MPT x 1/2 SAE FLR 121 2253 2253 Fuel Tube Assembly 122 8774 8774 Spark Plug, Flame Sensor 123 3037 3037 Spark Plug Nut 124 4340 4340 Thermostat Mounting Bracket 125 2254 2254 Thermostat Assembly 126 6070 6070 Loop Clamp, 5/16 127 7808 7808 Flame Control, Potted 128 1036 1036 Power Cord Assembly 129 8771 8771 Terminal Board 130 6223 6223 Bushing Strain Relief 131 8772 8772 Knob, Thermostat 132 8773 8773 Knob, Burn Rate Adjustment 133 2255 2255 Control Box 134 2256 2256 Base, Control Box 1* 8769 8769 Label, Safety Precautions 1* 8755 8755 Label, General Hazard Warning 1* 8733 8733 Label, Model 1* 8731 8731 Label, Operating Instructions 1* 6410A 6410A Label, Thermostate Warning 1* 7704 7704 Label, Warning Massachusetts 1* 6374 6374 Label, Warning Electrical 1* 7789 7789 Label, Wiring Schmatic 1* 8203 8203 Label, Hang Tag 1* 8679 8679 Label, BTU 170,000 1* 8770 8770 Manual, Operating Instructions 1* 6225 6225 Snap Bushing, 5/8 2* Item not shown on exploded viewPage -8-


MODELS170-F/SPC-170WARRANTYWe are pleased that you have selected our product and takethis opportunity to assure you that qualified service facilities areavailable if required. With the cooperation of independentdealers, a nationwide network of authorized servicing dealers isavailable for your servicing requirements.Should your product require servicing, read the section of the<strong>manual</strong> entitled “Servicing”.Who gets the warranty? The warranty is limited to the consumerwho originally purchases the product.What is covered? This limited warranty covers all imperfectionsin workmanship and material.What is not covered? This limited warranty does not coverdamage resulting from accident, misuse or abuse, lack ofproper maintenance, affixing of any attachments not providedwith the products, or loss of parts. IN NO EVENT SHALLSCHEU PRODUCTS COMPANY BE LIABLE FOR ANY SPECIAL,INCIDENTAL OR CONSEQUENTIAL DAMAGES NOR FOR ANYDAMAGES RESULTING FROM MISUSE OR MODIFICATION OFTHIS PRODUCT.Registering this heater within 10 days of date of purchaseensures the buyer the protection as stated on our limitedwarranty form.LIMITED WARRANTYThe company warrants this product to be free fromimperfections in material or workmanship, under normal andproper use in accordance with instructions of The Company, fora period of one year from the date of delivery to the buyer. TheCompany, at its option, will rep<strong>air</strong> or replace (f.o.b. factory,California) products returned by the buyer to the factory,California, transportation prepaid within said one year periodand found by the Company to have imperfections in material orworkmanship.the like and no implied warranty arising from course of dealingor usage of trade. This warranty will not apply to any productwhich has been rep<strong>air</strong>ed or altered outside of the Californiafactory in any respect which in our judgment affects its conditionor operation.Some states do not allow the exclusion or limitation ofincidental or consequential damages, so the above limitation orexclusion may not apply to you. This Warranty gives you specificlegal rights, and you may have other rights which vary from stateto state.SERVICE CENTERSScheu Products Company has over 1,000 service centersthroughout North America. Call (888) 619-7060 or e-mailphp@scheuco.com to request the service center nearest you.Include the Make and model of your heater in any e-mails.INSTRUCTIONS FOR ORDERING PARTSWe recommend that only parts supplied by the manufacturer beused on this unit. A locally purchased part may appear to beidentical, although in reality it might endanger the heater or thepersons operating the heater.The heater should be serviced only by a trained, experiencedservice person.Read the section on "Servicing" before ordering parts.For parts orders, call 888-619-7060 or e-mail us atphp@scheuco.com. Please have the model number of yourheater and the replacement part number when placing yourorder.If a part is damaged or missing, simply e-mail us atphp@scheuco.com, visit our website at scheuco.com, or callour Technical Support Department at (888) 619-7060.Address any Warranty Claims to the Customer ServiceDepartment, Scheu Products Company, Incorporated, P.O. Box250, Upland, California 91785, or e-mail us atphp@scheuco.com. Include your name, address and telephonenumber and include details concerning the claim. Also, supplyus with the purchase date and the name and address of thedealer from whom you purchased our product.The foregoing is the full extent of the responsibility of theCompany. There are no other warranties, express or implied.Specifically there is no warranty of fitness for a particularpurpose and there is no warranty of merchantability. In no eventshall the Company be liable for delay caused by imperfections,for consequential damages, or for any charges of the expenseof any nature incurred without its written consent. The cost ofrep<strong>air</strong> or replacement shall be the exclusive remedy for anybreach of warranty. There is no warranty against infringement ofPage -9-


Page -10-


Hand print only. Use black or blue ink pen to fill in this form. Cross or check inside the circle.Your InformationWarranty RegistrationFirst NameLast nameMailing Address-CityStatePostal codeE-mail AddressAnnual house hold income before tax $50,000Age of Purchaser 60 yearsYour PreferencesWho selected the heater? Male Female BothHeater will be used by? Individual BusinessHow did you learnabout our heater?AdvertisingStore displayOtherRelative/friendFold HerePreviously owned heaterIn choosing your heater the following categorieswere:FeaturesPortabilityPriceSomewhatImportantImportantVeryImportantWhat prompted you tobuy your heater?Sudden cold weatherReplaces old modelEmergency backup heatHard to heat locationQualityHeat OutputHeater on saleOtherWarrantyConstruction projectServiceabilityWhere will you use theheater?Construction siteShopWarehousePatioFuel economyEase of useOtherSizeProduct InformationFold Here/ /-Date of Purchase (MM/DD/YY)Cost of Heater ($)S/N (Located on a silver label on heater)Model Number (Located on a black and white label on heater)Brand Name All Pro Universal National RiversideStore Information where heater was purchasedStore NameCityStateType of Store Hardware Home Center Warehouse Retailer Discount Store Farm Supply Contractor’s Supply OtherRegistering this heater within 10 days of purchase ensures the buyer the protection as stated on our limited warranty form. Page -11-


SCHEU PRODUCTS COMPANY, INCATTN: MARKETING DEPARTMENT8855 BAKER AVENUERANCHO CUCAMONGA, CA 91730Visit our website for product information, technical support, customer service, and warranty registration at:WWW.ALLPRO-HEATERS.COM for All-Pro products or WWW.UNVERISAL-HEATERS.COM for Universal products.Page -12-