IF A TREE BEGINS TO FALL TOWARDS A TRANS-MISSION LINE DESPITE PRECAUTIONS, FOLLOWTHESE INSTRUCTIONS:Interrupt your work immediately.Bound so that only one foot <strong>to</strong>uches theground at a time and proceed <strong>to</strong> a distanceof at least 20 metres from the tree asquickly as possible.If a falling tree hits the <strong>line</strong> or gets caughtin the conduc<strong>to</strong>rs, notify <strong>Fingrid</strong>’s NetworkWhat you need <strong>to</strong> know before you do anythingFELLING OF TREES AND STORAGE OF TIMBERNear a <strong>transmission</strong> <strong>line</strong>, the trees must notbe cut <strong>to</strong>wards the <strong>line</strong>. Always verify thecorrect felling direction in accordance withthe safety instructions for timber harvestingwork. If necessary, <strong>Fingrid</strong> will provide furtherinformation and felling assistance.For safety reasons, timber or energy woodmust not be s<strong>to</strong>red under a <strong>transmission</strong> <strong>line</strong>or nearer than 10 metres from the closestphase conduc<strong>to</strong>r of the <strong>line</strong> in the horizontaldirection.Control Centre (tel. 030 395 4300) of thisSAFE USE OF MACHINERY8 immediately or call the nation-wide emer-Ordinary agricultural machinery can be operated9Voltage Minimum distance Minimum distancegency number 112.under a <strong>transmission</strong> <strong>line</strong>. Caution must be exercisedwhen operating agricultural machinery near trans mission or load beneath from phaselevel of <strong>to</strong> machinery <strong>to</strong> machinery or loadMake sure that nobody goes close <strong>to</strong> thesuspended tree.the <strong>to</strong>wer structures. If, however, <strong>to</strong>wer structures<strong>line</strong> phase conduc<strong>to</strong>rs conduc<strong>to</strong>rs inhorizontal directionare damaged, inform <strong>Fingrid</strong> immediately.DO NOT TRY TO LOOSEN A TREE WHICH TOUCHES110 kV 3 metres 5 metresPHASE CONDUCTORS BEFORE:If you are using an excava<strong>to</strong>r, crane or other220 kV 4 metres 5 metresthe <strong>line</strong> has been de-energised,machinery near a <strong>transmission</strong> <strong>line</strong>, make sure400 kV 5 metres 5 metresthe <strong>line</strong> has been provided with workthat you do not end up <strong>to</strong>o close <strong>to</strong> the live phasegrounding, andconduc<strong>to</strong>rs. No machinery must be brought in<strong>to</strong> IF THE LOADER OR LOAD TOUCHES THE CONDUCthe<strong>to</strong>wer area.you obtain permission from the owner ofTORS WHILE USING MACHINERY, PROCEED ASFOLLOWS:the <strong>line</strong> <strong>to</strong> loosen the tree.The table below presents the permitted minimumdistances of machinery with potential load fromYou are initially safe inside the cabin.the phase conduc<strong>to</strong>rs of a <strong>transmission</strong> <strong>line</strong>.Try <strong>to</strong> run the machine off the <strong>transmission</strong> <strong>line</strong>.If the machine catches fire or if its tyresstart <strong>to</strong> smoke, jump out of the machineNever drive machinery between the <strong>to</strong>wer legs,under a guy wire, or closer than 3 metres fromso that both of your feet <strong>to</strong>uch the groundthe <strong>to</strong>wer structures!simultaneously.Do not <strong>to</strong>uch the machine and groundTrees located close <strong>to</strong> a <strong>transmission</strong> <strong>line</strong>simultaneously.should always be felled by professionals.Bound so that only one foot <strong>to</strong>uches theground at a time and proceed <strong>to</strong> a distanceof at least 20 metres from the machine asfast as possible.Contact <strong>Fingrid</strong> immediately even if the<strong>transmission</strong> <strong>line</strong> is not visibly damaged.Make sure that nobody can access the area.5 metres110 kV 3 metres220 kV 4 metres400 kV 5 metres

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!