12.07.2015 Views

7.2 Prefabricated Construction Systems adopted in Hong Kong

7.2 Prefabricated Construction Systems adopted in Hong Kong

7.2 Prefabricated Construction Systems adopted in Hong Kong

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

2. Connect<strong>in</strong>g beam to columnPrecast beam is connected to column <strong>in</strong> a variety ofways. For non-rigid jo<strong>in</strong>t<strong>in</strong>g, corbel is usually formedon the column to support the precast beam. However,anchorage provision should be provided to secure themembers from seismic or w<strong>in</strong>d action.Rigid jo<strong>in</strong>t (moment resist<strong>in</strong>g) is common for build<strong>in</strong>grequir<strong>in</strong>g stronger performance. In this case, haunch<strong>in</strong>garrangement by <strong>in</strong>sert<strong>in</strong>g l<strong>in</strong>k bars between the columnand beam members and <strong>in</strong>fill the jo<strong>in</strong>t afterward withconcrete can often produce an acceptable jo<strong>in</strong><strong>in</strong>g result.It should be noted that suitable propp<strong>in</strong>g support shouldbe provided before the f<strong>in</strong>al sett<strong>in</strong>g of the jo<strong>in</strong>t.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!