S P E C I F I C A T I O N S<strong>Hach</strong> <strong>astro<strong>TOC</strong></strong> <strong>UV</strong><strong>Process</strong> <strong>TOC</strong> <strong>Analyzer</strong>Application—for industrialprocess water and wastewaterThe chemical/petrochemical industries have numerousapplications for on-line Total Organic Carbon(<strong>TOC</strong>) analysis, although the pharmaceutical, sugar,food and beverage industries have applicationsas well.The primary application is chemical and petrochemicalplants which use large amounts of waterfor processing product. These plants are organizedinto business units that are responsible for theproduction of a particular chemical product.Water is heated in the boiler to create steam thatis used for power generation, and cracking hydrocarbonsin preparation for further processing.Once the steam is used for heating in the productionprocess, the <strong>TOC</strong> levels are measured to determineif they are low enough for the steam to be repolishedand recirculated to avoid the high cost ofthe initial clean-up. If <strong>TOC</strong> levels in the steamexceed the limit for repolishing, then it is sent towaste. This application is commonly known as"Return Condensate <strong>TOC</strong>".Water from a natural source is used to cool theproduct in the heat exchanger and a <strong>TOC</strong> measurementis taken to detect organic carboncompounds for early detection of process leaksand determine if the water can be returned to it'sorigin or must be sent to waste for clean up. Thisapplication is known as "Cooling Water <strong>TOC</strong>".The unit outfall application is a <strong>TOC</strong> measurementtaken at the outfall of the business unit. Thiswater has been in contact with the process, contaminatedand sent directly into the wastewatertreatment plant. If the <strong>TOC</strong> levels indicate a spillcondition, the business unit notifies the treatmentplant of an incoming high <strong>TOC</strong> concentrationwaste stream. Operators can divert the stream intoa holding tank or pond, to be released later intothe treatment process at a controlled rate. The unitoutfall <strong>TOC</strong> measurement assures the business unitis charged fairly for the clean up.Industrial designThe <strong>Hach</strong> <strong>astro<strong>TOC</strong></strong> <strong>UV</strong> <strong>Process</strong> <strong>TOC</strong><strong>Analyzer</strong> is a rugged, low-maintenanceanalyzer designed to withstand the mostsevere conditions. Designed as a trueprocess analyzer, it features a dual-compartmentenclosure that separates andprotects the electronics from the analyticalsection.Modular construction, a streamlineddesign and large-bore flow paths simplifymaintenance and service. For severeapplications, an optional self-cleaningblowback filter removes large particlesfrom sample lines, and an optional airpurifier improves the quality of the compressedair supply by removing CO 2 .The modular design also offers a broadspectrum of factory-set analysis ranges.Advanced diagnosticsThe <strong>Hach</strong> <strong>astro<strong>TOC</strong></strong> <strong>UV</strong> <strong>Process</strong> <strong>TOC</strong><strong>Analyzer</strong> features advanced diagnosticsthat help protect the analyzer duringprocess spill conditions. Loss of sampleand loss of <strong>UV</strong> reactor flow are standardintegrated diagnostic features, as well asloss of sparger flow, loss of carrier gas,and pump tube deterioration. Optionalalarms for reagent levels and enclosurespills are also available.During a spill event, operators can attend toother instruments while the <strong>astro<strong>TOC</strong></strong> <strong>UV</strong> remainsprotected. A programmable process spill thresholdautomatically takes the instrument off-line andinto auto-clean mode when <strong>TOC</strong> readings exceedthis threshold. The instrument auto recovers andreturns to standard operation when <strong>TOC</strong> measurementsreturn to acceptable levels.The <strong>Hach</strong> <strong>astro<strong>TOC</strong></strong> <strong>UV</strong><strong>Process</strong> <strong>TOC</strong> <strong>Analyzer</strong>• Industrial design withstands the mostsevere conditions• Advanced diagnostics• Flexible analysis system allows analysis ofhigh salt and hard-to-oxidize samples• Based on the proven Astro process<strong>TOC</strong> analyzer platform• Drift- and interference-free NDIR detectorwith PVDF (KYNAR) flow-throughcell is impervious to corrosion


Flexible analysis systemThe <strong>astro<strong>TOC</strong></strong> <strong>UV</strong> <strong>Analyzer</strong> features dual-rangenon-dispersive infrared (NDIR) CO 2 detection witha multi-staged <strong>UV</strong> lamp reactor and on-boardsample dilution. These features enable high salt,high suspended solids, and hard-to-oxidize sampleanalysis. While the analyzer is factory-set for asingle range, it can be easily adapted to a broadand flexible selection of ranges, from 0-5 mg/L to0-20,000 mg/L.Based on an established platformThe <strong>Hach</strong> <strong>astro<strong>TOC</strong></strong> <strong>UV</strong> <strong>Process</strong> <strong>TOC</strong> <strong>Analyzer</strong> wasdesigned and manufactured based on more than25 years of industry-leading <strong>TOC</strong> analysis experience.With hundreds of installations worldwide, thisanalyzer was developed with input from many endusers and our extensive global service network.Principle of operationThe <strong>astro<strong>TOC</strong></strong> <strong>UV</strong> <strong>Analyzer</strong> combines chemical andultraviolet oxidation techniques in a low-temperaturereactor to deliver direct <strong>TOC</strong> measurements. It usesa multi-staged <strong>UV</strong> oxidation reactor and a chemicallyimpervious non-dispersive infrared (NDIR) CO 2detector system, assuring full compliance withStandard Methods 5310 C and EPA method 415.1.In the first analysis step, the sample is mixedwith acid, converting the total inorganic carbon(TIC) into CO 2 . The TIC sparger removes all theCO 2 from the sample solution. Subsequently, theTIC-free sample is mixed with sodium persulfateand routed through the <strong>UV</strong> reactor, oxidizing the<strong>TOC</strong> into CO 2 . The gas/liquid mixture is transportedby the carrier gas into the gas-liquid separator(GLS), where the sample gas is separated anddiverted into the NDIR detector for the direct,interference-free CO 2 measurement. The resultingCO 2 concentration measurement is directly proportionalto the original <strong>TOC</strong> concentration foundin the sample. The front panel displays the <strong>TOC</strong>concentration in mg/L.Detection methodASTM, EN, EPA, ISO and Standard Methods recommend<strong>TOC</strong> analysis methods using NDIR detection.This technique provides stable, accurate measurementby detecting CO 2 gas. The detector performsCO 2 measurement and compares it against a referencemeasurement. The difference between thetwo measurements is equal to the concentrationof CO 2 present in the cell.The NDIR measurement rays in the <strong>astro<strong>TOC</strong></strong><strong>UV</strong> <strong>Analyzer</strong> follow a direct path to a concave mirrorand a bundled path back to the receiver. Thisavoids the inherent drawbacks of the wall-bouncepath, including loss of sensitivity and inaccuratemeasurement due to the interference of dust particlesor water droplets on the NDIR cell wall.Non-corrosive NDIR detectorThe cell body of the <strong>astro<strong>TOC</strong></strong> <strong>UV</strong> NDIR detectionsystem is made of PVDF (KYNAR) that is imperviousto corrosion. The mirror and window are madeof sapphire, which is less susceptible to scratchingand therefore helps to provide a continuouslyaccurate measurement.LCD display shows <strong>TOC</strong>concentration in mg/LMulti-stage <strong>UV</strong>-reactor providesfull oxidation of <strong>TOC</strong>Integrated valve manifoldfor automatic calibration,validation, and cleaning


<strong>Hach</strong> <strong>astro<strong>TOC</strong></strong> <strong>UV</strong> <strong>Process</strong> <strong>TOC</strong><strong>Analyzer</strong> Specifications*Range0-5 up to 20,000 mg/L <strong>TOC</strong>Accuracy± 2% of full scale, non-diluted ranges at 25° C (77° F)± 4% of full scale, diluted ranges at 25° C (77° F)Repeatability± 2% of reading, non-diluted ranges at 25° C (77° F)± 4% of reading, diluted ranges at 25° C (77° F)Minimum Detection Limit≤0.015 mg/L for range 0-5 mg/L at 25° C (77° F)Response TimeT90 ≤ 8 minutes (includes TIC sparging and may varyaccording to range)Inlet Pressure0.15-6 bar (2-87 psig)Flow Rate20-200 mL/minSample Temperature Range2° C to 70° C (36° F to 158° F)Operating Temperature Range5° C to 40° C (41° F to 104° F)Recorder OutputsTwo 4-20 mA analog outputs selectable for sampleconcentration, analyzer system warning or autorange indicationAlarmsFive relays selectable for sample concentrationalarm, analyzer system warning or analyzer systemshutdown alarm. Each is equipped with an SPDT relaywith contacts rated for 3A resistive load at 250 VAC or0.5A at 30V.Optional Serial CommunicationOne multi-function RS232 or RS485 serial port(ModBUS, CSV)Power115/230 VAC 50/60 Hz (switch selectable)300 VA maximumSample Inlet/Outlet Connection1/4-inch OD tube, compression fittingDrain Connection1 1/2-inch OD standard drain pipeCarrier Gas1/8-inch OD tube, compression fittingClean, CO 2 -free air or Nitrogen at 2.8-6.2 bar(40-90 psig)Compliance/CertificationCE certified, listed to UL and CSA safety standards by ETLStandard Methods 5310 C, EPA 415.1EnclosureCold Rolled Steel epoxy powder coatedOptional Stainless SteelDimensionsApproximately 981 mm (38.6 inches) tall,675 mm (26.6 inches) wide, 220 mm (8.7 inches) deepMountingWall mountShipping Weight120 lbs. (54 kg)InstallationThe <strong>Hach</strong> <strong>astro<strong>TOC</strong></strong> <strong>UV</strong> <strong>Analyzer</strong> is designed to be wall-mounted easily with four 10 mm(3/8-inch) screws. Adequate clearance must be left at the sides and bottom of the enclosurefor plumbing and electrical connections. The sample inlet connection is 6 mm (1/4-inch) ODtube compression fitting and the drain connection is 1 1/2-inch OD standard drain pipe.Electrical connections are inside the instrument. Four thru-holes for 1/2” conduit fittings orfour PG13.5 strain relief are provided.*Subject to change without notice.


How to Order<strong>Hach</strong> <strong>astro<strong>TOC</strong></strong> <strong>UV</strong> <strong>Analyzer</strong>s are shipped with a start-up kit and a manual. An analyzer and a preferencepackage part number must be selected.<strong>Analyzer</strong>sCold Rolled Steel Stainless SteelH-4195-1010 H-4195-3010 HACH <strong>astro<strong>TOC</strong></strong> <strong>UV</strong>, 0 - 5 mg/l Range, 1 <strong>UV</strong> LampH-4195-1020 H-4195-3020 HACH <strong>astro<strong>TOC</strong></strong> <strong>UV</strong>, 0 - 10 mg/l Range, 1 <strong>UV</strong> LampH-4195-1030 H-4195-3030 HACH <strong>astro<strong>TOC</strong></strong> <strong>UV</strong>, 0 - 25 mg/l Range, 1 <strong>UV</strong> LampH-4195-1040 H-4195-3040 HACH <strong>astro<strong>TOC</strong></strong> <strong>UV</strong>, 0 - 50 mg/l Range, 1 <strong>UV</strong> LampH-4195-1050 H-4195-3050 HACH <strong>astro<strong>TOC</strong></strong> <strong>UV</strong>, 0 - 100 mg/l Range, 1 <strong>UV</strong> LampH-4195-1060 H-4195-3060 HACH <strong>astro<strong>TOC</strong></strong> <strong>UV</strong>, 0 - 200 mg/l Range, 1 <strong>UV</strong> Lamp, DilutionH-4195-1070 H-4195-3070 HACH <strong>astro<strong>TOC</strong></strong> <strong>UV</strong>, 0 - 500 mg/l Range, 1 <strong>UV</strong> Lamp, DilutionH-4195-2000 H-4195-4000 HACH <strong>astro<strong>TOC</strong></strong> <strong>UV</strong>, 0 - 100 mg/l Range, 2 <strong>UV</strong> LampsH-4195-2010 H-4195-4010 HACH <strong>astro<strong>TOC</strong></strong> <strong>UV</strong>, 0 - 200 mg/l Range, 2 <strong>UV</strong> LampsH-4195-2020 H-4195-4020 HACH <strong>astro<strong>TOC</strong></strong> <strong>UV</strong>, 0 - 500 mg/l Range, 2 <strong>UV</strong> LampsH-4195-2030 H-4195-4030 HACH <strong>astro<strong>TOC</strong></strong> <strong>UV</strong>, 0 - 1000 mg/l Range, 2 <strong>UV</strong> LampsH-4195-2040 H-4195-4040 HACH <strong>astro<strong>TOC</strong></strong> <strong>UV</strong>, 0 - 1000 mg/l Range, 2 <strong>UV</strong> Lamps, DilutionH-4195-2050 H-4195-4050 HACH <strong>astro<strong>TOC</strong></strong> <strong>UV</strong>, 0 - 2000 mg/l Range, 2 <strong>UV</strong> Lamps, DilutionH-4195-2060 H-4195-4060 HACH <strong>astro<strong>TOC</strong></strong> <strong>UV</strong>, 0 - 5000 mg/l Range, 2 <strong>UV</strong> Lamps, DilutionH-4195-2070 H-4195-4070 HACH <strong>astro<strong>TOC</strong></strong> <strong>UV</strong>, 0 - 10000 mg/l Range, 2 <strong>UV</strong> Lamps, DilutionH-4195-2080 H-4195-4080 HACH <strong>astro<strong>TOC</strong></strong> <strong>UV</strong>, 0 - 20000 mg/l Range, 2 <strong>UV</strong> Lamps, DilutionPreference Packages115V230V4P95-1000-00 4P95-2000-00 Cold Rolled Steel (no charge)4P95-1001-00 4P95-2001-00 Cold Rolled Steel, Level Detection Kit4P95-1010-00 4P95-2010-00 Cold Rolled Steel, Additional <strong>UV</strong> Lamp4P95-1011-00 4P95-2011-00 Cold Rolled Steel, Additional <strong>UV</strong> Lamp/Level Detection Kit4P95-1100-00 4P95-2100-00 Cold Rolled Steel, View Window4P95-1101-00 4P95-2101-00 Cold Rolled Steel, View Window/Level Detection Kit4P95-1110-00 4P95-2110-00 Cold Rolled Steel, View Window/Additional <strong>UV</strong> Lamp4P95-1111-00 4P95-2111-00 Cold Rolled Steel, View Window/Additional <strong>UV</strong> Lamp/Level Detection Kit4P95-1300-00 4P95-2300-00 Stainless Steel, View Window (no charge)4P95-1301-00 4P95-2301-00 Stainless Steel, View Window/Level Detection Kit4P95-1310-00 4P95-2310-00 Stainless Steel, View Window/Additional <strong>UV</strong> Lamp4P95-1311-00 4P95-2311-00 Stainless Steel, View Window/Additional <strong>UV</strong> Lamp/Level Detection KitAccessories120161 Free-standing Rack Assembly200123 <strong>astro<strong>TOC</strong></strong> <strong>UV</strong>, 1 Yr. Spare Parts Kit200124 <strong>astro<strong>TOC</strong></strong> <strong>UV</strong> , 2 Yr. Spare Parts Kit4000-0011 Z-Purge, LF/RT Mount, CL1 DIV2, A-D requires P/N 200130 Pneumatic Condenser Cooler Kit4200-1001 PS200, Blowback Filter, FM 100 µm4200-1002 PS200, Blowback Filter, FM 50 µm4200-1003 PS200, Blowback Filter, FM 300 µm4200-1004 PS200, Blowback Filter, FM 25 µm4200-1005 PS200, Blowback Filter, FM 500 µm4300-0001 AAS 300 CO2 Air Purifier with Electronic Timer for use with Compressed Air, 115V4300-0002 AAS 300 CO2 Air Purifier with Electronic Timer for use with Compressed Air, 230V4300-0003 AAS 300 CO2 Air Purifier with Pneumatic Timer for use with Compressed AirTypical Proposal SpecificationThe <strong>TOC</strong> analyzer shall employ <strong>UV</strong>/Persulfate oxidation utilizing a multi-staged <strong>UV</strong>-Reactor coupled with aNDIR CO 2 detection system to measure <strong>TOC</strong>.In addition, the analyzer shall consist of the following:• Dual enclosures with analytical/electrical separation• Epoxy powder-coated cold rolled steel, enclosure• Compliance with Standard Methods 5310 C and EPA Method 415.1• Grab sample and validation utilities for unknown sample or reference standard measurement• User programmable auto calibration, auto validation, and auto cleaning• Loss of sample flow and reactor feed detection• Hinged pump assembly module• Two 4-20 mA parameter mapped analog outputs• User programmable auto ranging over four ranges• Five-volt, free--function mapped relay outputs• One optional RS232 or RS485 serial communication output (ModBUS, CSV)• CE certified, listed to UL & CSA Safety Standards by ETLFor current priceinformation, technicalsupport, and orderingassistance, contactthe <strong>Hach</strong> office ordistributor servingyour area.In the United States, contact:HACH Company WorldHeadquartersP.O. Box 389Loveland, Colorado 80539-0389U.S.A.Telephone: 800-227-4224Fax: 970-669-2932E-mail: orders@hach.comWebsite: www.hach.comU.S. exporters and customersin Canada, Latin America,sub-Saharan Africa, Asia, andAustralia/New Zealand, contact:HACH Company WorldHeadquartersP.O. Box 389Loveland, Colorado 80539-0389U.S.A.Telephone: 970-669-3050Fax: 970-461-3939E-mail: intl@hach.comWebsite: www.hach.comIn Europe, the Middle East, andMediterrean Africa, contact:HACH Companyc/o Dr. Bruno Lange GmbH.Willstätterstr. 11D-40549 DusseldorfGermanyTelephone: 49-211-52-880Fax: 49-211-52-88231E-mail: <strong>Hach</strong>@drlange.deLit. No. 2432J23 Printed in U.S.A.©<strong>Hach</strong> Company, 2002. All rights reserved.