12.07.2015 Views

Ultracom cxi - Abacus Flame

Ultracom cxi - Abacus Flame

Ultracom cxi - Abacus Flame

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

INSTALLATION9 Evacuation of combustion gas9.1 RegulationbOnly flue accessories supplied by Glow-wormmust be used.Different flue outlet configurations can be carried out.• Consult your supplier for more information about the otherpossibilities and associated accessories.bIfthe flue terminal is positioned near a lightsource insects may enter the flue system.Where safe and practical to do so advise thehomeowner to check the flue outlet and clearvisible insects from the terminal end.44 mm/m1 243• Standard flue terminal kits have an in-built fall back to theboiler to drain the condensate. These can be fitted levelbetween the appliance and the termination position. All otherextended flues must have a fall of at least 44mm/mThe maximum length of the flue outlet is defined according to itstype (for example C13).• Whatever the kind of flue system chosen, observe theminimum distances indicated in the chart below to positionthe flue terminals.• To install the flue, refer to the separate flue instructionsupplied with your appliance.• Explain these requirements to the user of the appliance.aIfnecessary, you must install a terminalprotection kit.bCaution!The connection between the flue elbowand the flue outlet must be sealed.In GB the minimum acceptable siting dimensions for theterminal from obstructions, other terminals and ventilationopenings are shown in diagram overleaf.In IE the minimum distances for flue terminal positioning mustbe those detailed in I.S.813 “Domestic Gas Installations”.The terminal must be exposed to the external air, allowing freepassage of air across it at all times.Being a condensing boiler some pluming may occur fromthe flue outlet. This should be taken into consideration whenselecting the position for the terminal.Carports or similar extensions of a roof only, or a roof and onewall, require special consideration with respect to any openings,doors, vents or windows under the roof. Care is requiredto protect the roof if made of plastic sheeting. If the carportcomprises of a roof and two or more walls, seek advice from thelocal gas supply company before installing the boiler.0020085231_02 - 05/10 - Glow-worm- 17 -

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!