Ultracom cxi - Abacus Flame
Ultracom cxi - Abacus Flame
Ultracom cxi - Abacus Flame
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
INSTALLATION9.2 Flue configuration description9.2.1 Horizontal concentric flue Ø 60/100 mmor Ø 80/125 mm (C13 type installation)aIfnecessary, you must install a terminalprotection kit.Ø 60/100 mmEach time an additional 90° bend is necessary (or 2 at 45°), thelength (L) must be reduced by 1 m.9.2.2 Vertical concentric flue Ø 60/100 mmor Ø 80/125 mm (C33 type installation)L163LKey1 Gasket (fitted)Ø 80/125 mmTypeØ 60/100Ø 80/125Max length (L)10 m25 mLEach time an additional 90° bend is necessary (or 2 at 45°), thelength (L) must be reduced by 1 m.1Key1 Gasket (fitted)TypeØ 60/100Ø 80/125Max length10 m25 m0020085231_02 - 05/10 - Glow-worm- 19 -