12.07.2015 Views

ECR 2013 – Final Programme - myESR.org

ECR 2013 – Final Programme - myESR.org

ECR 2013 – Final Programme - myESR.org

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Scientific SessionsB-0275 – B-028914:45B-0275 Dose values in eye lens in paediatric brain computedtomography: influence of different protocolsC. Carriço 1 , M. Inácio 1 , A. Kristiansen 2 , M. Larsen 2 , J. Santos 1 , S. Holm 2 , G. Paulo 1 ;1Coimbra/PT, 2 Odense/DK14:54B-0276 Influence of different arm positioning of MSCT of chestby apply automatic tube current modulation techniqueZ.-X. Ding, Z. Wang; Hangzhou/CN15:03B-0277 The effectiveness of lead apron for radiationprotection in CTN. Weber, P. Monnin, C. Elandoy, S. Ding; Lausanne/CH15:12B-0278 Optimisation of local diagnostic reference levels inhead computed tomographyM. Monteiro, A. Carvalho, J. Matias, J. Santos; Coimbra/PT15:21B-0279 Comparison of radiation dose and image qualitybetween sequential and spiral brain CTI. Pace, F. Zarb; Msida/MT14:54B-0286 A patient dose managing solution identifies erroneousparameter settings in CT acquisition protocols, andcontributes towards lowering radiation exposureT. De Bondt 1 , Q. Collier 1 , R. Salgado 1 , M. Geldof 1 , F. Deferme 1 , J. Valette 2 ,A. Jomier 2 , W. Van Hecke 1 , P.M. Parizel 1 ; 1 Antwerp/BE, 2 Mutzig/FR15:03B-0287 Evaluation of the quality of abdominal computedtomography images reconstructed with iterativereconstruction techniqueL. Henriksson, A. Persson, M. Sandb<strong>org</strong>; Linköping/SE15:12B-0288 Improved image quality of virtual non-contrast dualenergyCT images using a new iodine subtractionalgorithmA. Helck, N. Hummel, F. Meinel, S.F. Thieme, M.F. Reiser, A. Graser,T.R.C. Johnson; Munich/DE15:21B-0289 Image quality of monoenergetic low-keV datasets forlower extremity dual-energy CT angiographyS. Sudarski, D. Schneider, P. Apfaltrer, S.O. Schönberg, T. Henzler;Mannheim/DE14:00–15:30 Room ZComputer ApplicationsSS 205 Quantitative image analysis andoptimisationModerators: L. Faggioni; Pisa/IT, M. Fatehi; Tehran/IR14:00B-0280 Consistent automatic adipose tissue quantification inMR abdomen imagesD. Smeets, W. Van Hecke, D. Loeckx; Leuven/BE14:09B-0281 Computational texture analysis in interstitial lungdisease: comparison of descriptors and classificationaccuracyJ. Ofner 1 , C. Mueller-Mang 1 , A. Burner 1 , D. Markonis 2 , A. Depeursinge 2 ,H. Mueller 2 , G. Langs 1 ; 1 Vienna/AT, 2 Sierre/CH14:18B-0282 Quantification of correlations between somatostatinreceptors expression in biopsies from neuroendocrinetumours and PET/CT uptake values in the context ofpersonalised medicineM. Athelogou 1 , D. Kaemmerer 2 , A. Lupp 3 , V. Prasad 4 , R. Schoenmeyer 1 ,G. Binnig 1 , R. Baum 2 ; 1 Munich/DE, 2 Bad Berka/DE, 3 Jena/DE, 4 Berlin/DE14:27B-0283 3D analysis CT software in volumetric anddensitometric analysis of urinary stonesM. Moschetta, A. Scardapane, M. Telegrafo, G. Angelelli, A.A. Stabile Ianora;Bari/IT14:36B-0284 The 3DSlicer open-source platform for segmentation,registration, quantitative imaging and 3D visualizationof biomedical image dataS. Pujol 1 , S. Pieper 2 , R. Kikinis 1 ; 1 Boston, MA/US, 2 Cambridge, MA/US14:45B-0285 Can the CT acquisition protocol be used incombination with the study description to optimisepatient dose tracking for CT examinations?T. De Bondt 1 , Q. Collier 1 , R. Salgado 1 , M. Geldof 1 , F. Deferme 1 , J. Valette 2 ,A. Jomier 2 , W. Van Hecke 1 , P.M. Parizel 1 ; 1 Antwerp/BE, 2 Mutzig/FR228

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!