12.07.2015 Views

View Actual EPA Method 8081A (PDF File)

View Actual EPA Method 8081A (PDF File)

View Actual EPA Method 8081A (PDF File)

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

confirmation techniques may be employed). The single-column approach may employ either narrowbore(#0.32 mm ID) columns or wide-bore (0.53 mm ID) columns. The dual-column approachinvolves a single injection that is split between two columns that are mounted in a single gaschromatograph. The dual-column approach employs only wide-bore (0.53 mm ID) columns.The columns listed in this section were the columns used to develop the method performancedata. The mention of these columns in this method is not intended to exclude the use of othercolumns that may be developed. Laboratories may use other capillary columns provided that theydocument method performance data (e.g., chromatographic resolution, analyte breakdown, andMDLs) that equals or exceeds the performance described in this method, or as appropriate for theintended application.4.2.1 Narrow-bore columns for single-column analysis (use both columns to confirmcompound identifications unless another confirmation technique such as GC/MS is employed).4.2.1.1 30 m x 0.25 or 0.32 mm ID fused silica capillary column chemicallybonded with SE-54 (DB-5 or equivalent), 1 µm film thickness.4.2.1.2 30 m x 0.25 mm ID fused silica capillary column chemically bonded with35 percent phenyl methylpolysiloxane (DB-608, SPB-608, or equivalent), 2.5 µm coatingthickness, 1 µm film thickness.4.2.1.3 Narrow bore columns should be installed in split/splitless (Grob-type)injectors.4.2.2 Wide-bore columns for single-column analysis (use two of the three columnslisted to confirm compound identifications unless another confirmation technique such asGC/MS is employed).4.2.2.1 30 m x 0.53 mm ID fused silica capillary column chemically bonded with35 percent phenyl methylpolysiloxane (DB-608, SPB-608, RTx-35, or equivalent), 0.5 µmor 0.83 µm film thickness.4.2.2.2 30 m x 0.53 mm ID fused silica capillary column chemically bonded with50 percent phenyl methylpolysiloxane (DB-1701, or equivalent), 1.0 µm film thickness.4.2.2.3 30 m x 0.53 mm ID fused silica capillary column chemically bonded with95 percent dimethyl - 5 percent diphenyl polysiloxane (DB-5, SPB-5, RTx-5, orequivalent), 1.5 µm film thickness.4.2.2.4 Wide-bore columns should be installed in 1/4 inch injectors, withdeactivated liners designed specifically for use with these columns.4.2.3 Wide-bore columns for dual-column analysis (choose one of the two pairs ofcolumns listed below).4.2.3.1 Column pair 130 m x 0.53 mm ID fused silica capillary column chemically bonded with SE-54(DB-5, SPB-5, RTx-5, or equivalent), 1.5 µm film thickness.CD-ROM <strong>8081A</strong> - 6 Revision 1December 1996

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!